From version < 77.5 >
edited by Xiaoling
on 2022/05/23 16:07
To version < 80.1 >
edited by Edwin Chen
on 2022/05/24 23:53
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -1,5 +1,5 @@
1 1  (% style="text-align:center" %)
2 -[[image:image-20220523115324-1.jpeg||height="500" width="500"]]
2 +[[image:image-20220523115324-1.jpeg||height="317" width="317"]]
3 3  
4 4  
5 5  **LHT65N LoRaWAN Temperature & Humidity Sensor Manual**
... ... @@ -7,19 +7,6 @@
7 7  
8 8  
9 9  
10 -
11 -
12 -
13 -
14 -
15 -
16 -
17 -
18 -
19 -
20 -
21 -
22 -
23 23  **Table of Contents:**
24 24  
25 25  {{toc/}}
... ... @@ -27,7 +27,7 @@
27 27  
28 28  
29 29  
30 -= 1.Introduction =
17 += 1. Introduction =
31 31  
32 32  == 1.1 What is LHT65N Temperature & Humidity Sensor ==
33 33  
... ... @@ -147,7 +147,7 @@
147 147  
148 148  [[image:image-20220515123819-1.png||height="379" width="317"]]
149 149  
150 -[[image:image-20220523153201-19.png||height="163" width="739"]]
137 +[[image:image-20220523153201-19.png||height="180" width="818"]]
151 151  
152 152  == 2.3 Example to join LoRaWAN network ==
153 153  
... ... @@ -232,7 +232,7 @@
232 232  [[Humidity>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
233 233  )))
234 234  )))|(% style="width:47px" %)(((
235 -[[Ext>>path:#Extension_Sensor]] #
222 +[[Ext>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.5Ext23]] #
236 236  )))|(% style="width:51px" %)(((
237 237  [[Ext value>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.6Extvalue]]
238 238  )))
... ... @@ -414,10 +414,18 @@
414 414  
415 415  == 2.6 Datalog Feature ==
416 416  
417 -This feature is always enabled. When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot.
404 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, LHT65N will store the reading for future retrieving purposes. There are two ways for IoT servers to get datalog from LHT65N.
418 418  
419 -=== 2.6.1 Unix TimeStamp ===
406 +=== 2.6.1 Ways to get datalog via LoRaWAN ===
420 420  
408 +There are two methods:
409 +
410 +1. IoT Server sends a downlink LoRaWAN command to [poll the value>PollSensorValue].
411 +1.
412 +
413 +
414 +=== 2.6.2 Unix TimeStamp ===
415 +
421 421  LHT65N uses Unix TimeStamp format based on
422 422  
423 423  [[image:image-20220523001219-11.png||height="97" width="627"]]
... ... @@ -435,7 +435,7 @@
435 435  
436 436  So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25
437 437  
438 -=== 2.6.2 Set Device Time ===
433 +=== 2.6.3 Set Device Time ===
439 439  
440 440  (((
441 441  There are two ways to set device’s time:
... ... @@ -469,7 +469,7 @@
469 469  User needs to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server.
470 470  )))
471 471  
472 -=== 2.6.3 Poll sensor value ===
467 +=== [[2.6.4 Poll sensor value>>2.6.4 Poll sensor value||anchor="PollSensorValue"]] ===
473 473  
474 474  User can poll sensor value based on timestamps from the server. Below is the downlink command.
475 475  
... ... @@ -480,7 +480,7 @@
480 480  )))
481 481  
482 482  (((
483 -For example, downlink command **31 5FC5F350 5FC6 0160 05**
478 +For example, downlink command (% style="display:none" %) (%%)**31 5FC5F350 5FC6 0160 05**
484 484  )))
485 485  
486 486  (((
... ... @@ -492,7 +492,7 @@
492 492  )))
493 493  
494 494  
495 -=== 2.6.4 Datalog Uplink payload ===
490 +=== 2.6.5 Datalog Uplink payload ===
496 496  
497 497  The Datalog poll reply uplink will use below payload format.
498 498  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved