<
From version < 77.3 >
edited by Xiaoling
on 2022/05/23 16:02
To version < 80.1 >
edited by Edwin Chen
on 2022/05/24 23:53
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -1,5 +1,5 @@
1 1  (% style="text-align:center" %)
2 -[[image:image-20220523115324-1.jpeg||height="500" width="500"]]
2 +[[image:image-20220523115324-1.jpeg||height="317" width="317"]]
3 3  
4 4  
5 5  **LHT65N LoRaWAN Temperature & Humidity Sensor Manual**
... ... @@ -7,10 +7,6 @@
7 7  
8 8  
9 9  
10 -
11 -
12 -
13 -
14 14  **Table of Contents:**
15 15  
16 16  {{toc/}}
... ... @@ -18,9 +18,8 @@
18 18  
19 19  
20 20  
17 += 1. Introduction =
21 21  
22 -= 1.Introduction =
23 -
24 24  == 1.1 What is LHT65N Temperature & Humidity Sensor ==
25 25  
26 26  (((
... ... @@ -139,7 +139,7 @@
139 139  
140 140  [[image:image-20220515123819-1.png||height="379" width="317"]]
141 141  
142 -[[image:image-20220523153201-19.png||height="163" width="739"]]
137 +[[image:image-20220523153201-19.png||height="180" width="818"]]
143 143  
144 144  == 2.3 Example to join LoRaWAN network ==
145 145  
... ... @@ -224,7 +224,7 @@
224 224  [[Humidity>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
225 225  )))
226 226  )))|(% style="width:47px" %)(((
227 -[[Ext>>path:#Extension_Sensor]] #
222 +[[Ext>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.5Ext23]] #
228 228  )))|(% style="width:51px" %)(((
229 229  [[Ext value>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.6Extvalue]]
230 230  )))
... ... @@ -406,10 +406,18 @@
406 406  
407 407  == 2.6 Datalog Feature ==
408 408  
409 -This feature is always enabled. When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot.
404 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, LHT65N will store the reading for future retrieving purposes. There are two ways for IoT servers to get datalog from LHT65N.
410 410  
411 -=== 2.6.1 Unix TimeStamp ===
406 +=== 2.6.1 Ways to get datalog via LoRaWAN ===
412 412  
408 +There are two methods:
409 +
410 +1. IoT Server sends a downlink LoRaWAN command to [poll the value>PollSensorValue].
411 +1.
412 +
413 +
414 +=== 2.6.2 Unix TimeStamp ===
415 +
413 413  LHT65N uses Unix TimeStamp format based on
414 414  
415 415  [[image:image-20220523001219-11.png||height="97" width="627"]]
... ... @@ -427,7 +427,7 @@
427 427  
428 428  So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25
429 429  
430 -=== 2.6.2 Set Device Time ===
433 +=== 2.6.3 Set Device Time ===
431 431  
432 432  (((
433 433  There are two ways to set device’s time:
... ... @@ -461,7 +461,7 @@
461 461  User needs to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server.
462 462  )))
463 463  
464 -=== 2.6.3 Poll sensor value ===
467 +=== [[2.6.4 Poll sensor value>>2.6.4 Poll sensor value||anchor="PollSensorValue"]] ===
465 465  
466 466  User can poll sensor value based on timestamps from the server. Below is the downlink command.
467 467  
... ... @@ -472,7 +472,7 @@
472 472  )))
473 473  
474 474  (((
475 -For example, downlink command **31 5FC5F350 5FC6 0160 05**
478 +For example, downlink command (% style="display:none" %) (%%)**31 5FC5F350 5FC6 0160 05**
476 476  )))
477 477  
478 478  (((
... ... @@ -484,7 +484,7 @@
484 484  )))
485 485  
486 486  
487 -=== 2.6.4 Datalog Uplink payload ===
490 +=== 2.6.5 Datalog Uplink payload ===
488 488  
489 489  The Datalog poll reply uplink will use below payload format.
490 490  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0