Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-20220523115324-1.jpeg||height=" 500" width="500"]]2 +[[image:image-20220523115324-1.jpeg||height="317" width="317"]] 3 3 4 4 5 5 **LHT65N LoRaWAN Temperature & Humidity Sensor Manual** ... ... @@ -7,10 +7,6 @@ 7 7 8 8 9 9 10 - 11 - 12 - 13 - 14 14 **Table of Contents:** 15 15 16 16 {{toc/}} ... ... @@ -17,8 +17,9 @@ 17 17 18 18 19 19 20 -= 1.Introduction = 21 21 17 += 1. Introduction = 18 + 22 22 == 1.1 What is LHT65N Temperature & Humidity Sensor == 23 23 24 24 ((( ... ... @@ -137,7 +137,7 @@ 137 137 138 138 [[image:image-20220515123819-1.png||height="379" width="317"]] 139 139 140 -[[image:image-20220523153201-19.png||height="1 63" width="739"]]137 +[[image:image-20220523153201-19.png||height="180" width="818"]] 141 141 142 142 == 2.3 Example to join LoRaWAN network == 143 143 ... ... @@ -222,7 +222,7 @@ 222 222 [[Humidity>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]] 223 223 ))) 224 224 )))|(% style="width:47px" %)((( 225 -[[Ext>>path: #Extension_Sensor]] #222 +[[Ext>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.5Ext23]] # 226 226 )))|(% style="width:51px" %)((( 227 227 [[Ext value>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.6Extvalue]] 228 228 ))) ... ... @@ -404,10 +404,14 @@ 404 404 405 405 == 2.6 Datalog Feature == 406 406 407 - Thisfeature isalwaysenabled. When userwants toretrievethe sensorvalue, hecansendapollcommand from theIoT platformto askLHT65Ntosendthevalue inthe requiredtimeslot.404 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, LHT65N will store the reading for future retrieving purposes. There are two ways for IoT servers to get datalog from LHT65N. 408 408 409 -=== 2.6.1 UnixTimeStamp===406 +=== 2.6.1 Ways to get datalog via LoRaWAN === 410 410 408 +When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot. 409 + 410 +=== 2.6.2 Unix TimeStamp === 411 + 411 411 LHT65N uses Unix TimeStamp format based on 412 412 413 413 [[image:image-20220523001219-11.png||height="97" width="627"]] ... ... @@ -425,7 +425,7 @@ 425 425 426 426 So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 427 427 428 -=== 2.6. 2Set Device Time ===429 +=== 2.6.3 Set Device Time === 429 429 430 430 ((( 431 431 There are two ways to set device’s time: ... ... @@ -459,7 +459,7 @@ 459 459 User needs to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server. 460 460 ))) 461 461 462 -=== 2.6. 3Poll sensor value ===463 +=== 2.6.4 Poll sensor value === 463 463 464 464 User can poll sensor value based on timestamps from the server. Below is the downlink command. 465 465 ... ... @@ -470,7 +470,7 @@ 470 470 ))) 471 471 472 472 ((( 473 -For example, downlink command **31 5FC5F350 5FC6 0160 05** 474 +For example, downlink command (% style="display:none" %) (%%)**31 5FC5F350 5FC6 0160 05** 474 474 ))) 475 475 476 476 ((( ... ... @@ -482,7 +482,7 @@ 482 482 ))) 483 483 484 484 485 -=== 2.6. 4Datalog Uplink payload ===486 +=== 2.6.5 Datalog Uplink payload === 486 486 487 487 The Datalog poll reply uplink will use below payload format. 488 488