<
From version < 77.2 >
edited by Xiaoling
on 2022/05/23 16:01
To version < 76.7 >
edited by Xiaoling
on 2022/05/23 15:40
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -6,11 +6,6 @@
6 6  
7 7  
8 8  
9 -
10 -
11 -
12 -
13 -
14 14  **Table of Contents:**
15 15  
16 16  {{toc/}}
... ... @@ -303,7 +303,7 @@
303 303  
304 304  Timestamp mode is designed for LHT65N with E3 probe, it will send the uplink payload with Unix timestamp. With the limitation of 11 bytes (max distance of AU915/US915/AS923 band), the time stamp mode will be lack of BAT voltage field, instead, it shows the battery status. The payload is as below:
305 305  
306 -(% border="1" style="background-color:#ffffcc; color:green; width:510px" %)
301 +(% border="1" style="background-color:#ffffcc; color:green; width:468px" %)
307 307  |(% style="width:96px" %)(((
308 308  **Size(bytes)**
309 309  )))|(% style="width:71px" %)(((
... ... @@ -490,7 +490,7 @@
490 490  **Retrieval data payload**
491 491  )))
492 492  
493 -(% border="1" style="background-color:#ffffcc; color:green; width:510px" %)
488 +(% border="1" style="background-color:#ffffcc; color:green; width:469px" %)
494 494  |(% style="width:93px" %)(((
495 495  (((
496 496  **Size(bytes)**
... ... @@ -803,24 +803,14 @@
803 803  
804 804  [[image:image-20220523150701-2.png]]
805 805  
806 -(((
807 807  **Downlink Command: 0x01**
808 -)))
809 809  
810 -(((
811 811  Format: Command Code (0x01) followed by 3 bytes time value.
812 -)))
813 813  
814 -(((
815 815  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
816 -)))
817 817  
818 -* (((
819 -**Example 1**: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
820 -)))
821 -* (((
822 -**Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
823 -)))
807 +* **Example 1**: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
808 +* **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
824 824  
825 825  == 4.2 Set External Sensor Mode ==
826 826  
... ... @@ -830,27 +830,15 @@
830 830  
831 831  [[image:image-20220523150759-3.png]]
832 832  
833 -(((
834 834  **Downlink Command: 0xA2**
835 -)))
836 836  
837 -(((
838 838  Total bytes: 2 ~~ 5 bytes
839 -)))
840 840  
841 -(((
842 842  **Example:**
843 -)))
844 844  
845 -* (((
846 -0xA201: Set external sensor type to E1
847 -)))
848 -* (((
849 -0xA209: Same as AT+EXT=9
850 -)))
851 -* (((
852 -0xA20702003c,Same as AT+SETCNT=60
853 -)))
824 +* 0xA201: Set external sensor type to E1
825 +* 0xA209: Same as AT+EXT=9
826 +* 0xA20702003c,Same as AT+SETCNT=60
854 854  
855 855  == 4.3 Enable/Disable uplink Temperature probe ID ==
856 856  
... ... @@ -878,13 +878,9 @@
878 878  
879 879  [[image:image-20220523151052-5.png]]
880 880  
881 -(((
882 882  **Downlink Command:**
883 -)))
884 884  
885 -(((
886 886  No downlink command for this feature.
887 -)))
888 888  
889 889  == 4.5 Quit AT Command ==
890 890  
... ... @@ -924,17 +924,11 @@
924 924  
925 925  == 4.8 Set Time Sync Mode ==
926 926  
927 -(((
928 928  Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply this command.
929 -)))
930 930  
931 -(((
932 932  SYNCMOD is set to 1 by default. If user want to set a different time from LoRaWAN server, user need to set this to 0.
933 -)))
934 934  
935 -(((
936 936  **AT Command:**
937 -)))
938 938  
939 939  [[image:image-20220523151336-9.png]]
940 940  
... ... @@ -1024,7 +1024,7 @@
1024 1024  = 6. Order Info =
1025 1025  
1026 1026  (((
1027 -Part Number: (% style="color:#4f81bd" %)** LHT65N-XX-YY**
990 +Part Number: (% style="color:#4f81bd" %)** LHT65N-XX**
1028 1028  )))
1029 1029  
1030 1030  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0