Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -298,7 +298,7 @@ 298 298 299 299 Timestamp mode is designed for LHT65N with E3 probe, it will send the uplink payload with Unix timestamp. With the limitation of 11 bytes (max distance of AU915/US915/AS923 band), the time stamp mode will be lack of BAT voltage field, instead, it shows the battery status. The payload is as below: 300 300 301 -(% border="1" style="background-color:#ffffcc; color:green; width: 510px" %)301 +(% border="1" style="background-color:#ffffcc; color:green; width:468px" %) 302 302 |(% style="width:96px" %)((( 303 303 **Size(bytes)** 304 304 )))|(% style="width:71px" %)((( ... ... @@ -485,7 +485,7 @@ 485 485 **Retrieval data payload** 486 486 ))) 487 487 488 -(% border="1" style="background-color:#ffffcc; color:green; width: 510px" %)488 +(% border="1" style="background-color:#ffffcc; color:green; width:469px" %) 489 489 |(% style="width:93px" %)((( 490 490 ((( 491 491 **Size(bytes)** ... ... @@ -798,24 +798,14 @@ 798 798 799 799 [[image:image-20220523150701-2.png]] 800 800 801 -((( 802 802 **Downlink Command: 0x01** 803 -))) 804 804 805 -((( 806 806 Format: Command Code (0x01) followed by 3 bytes time value. 807 -))) 808 808 809 -((( 810 810 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 811 -))) 812 812 813 -* ((( 814 -**Example 1**: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 815 -))) 816 -* ((( 817 -**Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 818 -))) 807 +* **Example 1**: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 808 +* **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 819 819 820 820 == 4.2 Set External Sensor Mode == 821 821 ... ... @@ -825,27 +825,15 @@ 825 825 826 826 [[image:image-20220523150759-3.png]] 827 827 828 -((( 829 829 **Downlink Command: 0xA2** 830 -))) 831 831 832 -((( 833 833 Total bytes: 2 ~~ 5 bytes 834 -))) 835 835 836 -((( 837 837 **Example:** 838 -))) 839 839 840 -* ((( 841 -0xA201: Set external sensor type to E1 842 -))) 843 -* ((( 844 -0xA209: Same as AT+EXT=9 845 -))) 846 -* ((( 847 -0xA20702003c,Same as AT+SETCNT=60 848 -))) 824 +* 0xA201: Set external sensor type to E1 825 +* 0xA209: Same as AT+EXT=9 826 +* 0xA20702003c,Same as AT+SETCNT=60 849 849 850 850 == 4.3 Enable/Disable uplink Temperature probe ID == 851 851 ... ... @@ -873,13 +873,9 @@ 873 873 874 874 [[image:image-20220523151052-5.png]] 875 875 876 -((( 877 877 **Downlink Command:** 878 -))) 879 879 880 -((( 881 881 No downlink command for this feature. 882 -))) 883 883 884 884 == 4.5 Quit AT Command == 885 885 ... ... @@ -919,17 +919,11 @@ 919 919 920 920 == 4.8 Set Time Sync Mode == 921 921 922 -((( 923 923 Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply this command. 924 -))) 925 925 926 -((( 927 927 SYNCMOD is set to 1 by default. If user want to set a different time from LoRaWAN server, user need to set this to 0. 928 -))) 929 929 930 -((( 931 931 **AT Command:** 932 -))) 933 933 934 934 [[image:image-20220523151336-9.png]] 935 935 ... ... @@ -1019,7 +1019,7 @@ 1019 1019 = 6. Order Info = 1020 1020 1021 1021 ((( 1022 -Part Number: (% style="color:#4f81bd" %)** LHT65N-XX -YY**990 +Part Number: (% style="color:#4f81bd" %)** LHT65N-XX** 1023 1023 ))) 1024 1024 1025 1025 (((