Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -798,24 +798,14 @@ 798 798 799 799 [[image:image-20220523150701-2.png]] 800 800 801 -((( 802 802 **Downlink Command: 0x01** 803 -))) 804 804 805 -((( 806 806 Format: Command Code (0x01) followed by 3 bytes time value. 807 -))) 808 808 809 -((( 810 810 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 811 -))) 812 812 813 -* ((( 814 -**Example 1**: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 815 -))) 816 -* ((( 817 -**Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 818 -))) 807 +* **Example 1**: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 808 +* **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 819 819 820 820 == 4.2 Set External Sensor Mode == 821 821 ... ... @@ -825,27 +825,15 @@ 825 825 826 826 [[image:image-20220523150759-3.png]] 827 827 828 -((( 829 829 **Downlink Command: 0xA2** 830 -))) 831 831 832 -((( 833 833 Total bytes: 2 ~~ 5 bytes 834 -))) 835 835 836 -((( 837 837 **Example:** 838 -))) 839 839 840 -* ((( 841 -0xA201: Set external sensor type to E1 842 -))) 843 -* ((( 844 -0xA209: Same as AT+EXT=9 845 -))) 846 -* ((( 847 -0xA20702003c,Same as AT+SETCNT=60 848 -))) 824 +* 0xA201: Set external sensor type to E1 825 +* 0xA209: Same as AT+EXT=9 826 +* 0xA20702003c,Same as AT+SETCNT=60 849 849 850 850 == 4.3 Enable/Disable uplink Temperature probe ID == 851 851 ... ... @@ -873,13 +873,9 @@ 873 873 874 874 [[image:image-20220523151052-5.png]] 875 875 876 -((( 877 877 **Downlink Command:** 878 -))) 879 879 880 -((( 881 881 No downlink command for this feature. 882 -))) 883 883 884 884 == 4.5 Quit AT Command == 885 885 ... ... @@ -919,17 +919,11 @@ 919 919 920 920 == 4.8 Set Time Sync Mode == 921 921 922 -((( 923 923 Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply this command. 924 -))) 925 925 926 -((( 927 927 SYNCMOD is set to 1 by default. If user want to set a different time from LoRaWAN server, user need to set this to 0. 928 -))) 929 929 930 -((( 931 931 **AT Command:** 932 -))) 933 933 934 934 [[image:image-20220523151336-9.png]] 935 935 ... ... @@ -1019,7 +1019,7 @@ 1019 1019 = 6. Order Info = 1020 1020 1021 1021 ((( 1022 -Part Number: (% style="color:#4f81bd" %)** LHT65N-XX -YY**990 +Part Number: (% style="color:#4f81bd" %)** LHT65N-XX** 1023 1023 ))) 1024 1024 1025 1025 (((