... ... @@ -6,6 +6,11 @@
6 6  
7 7  
8 8  
9 +
10 +
11 +
12 +
13 +
9 9  **Table of Contents:**
10 10  
11 11  {{toc/}}
... ... @@ -298,7 +298,7 @@
298 298  
299 299  Timestamp mode is designed for LHT65N with E3 probe, it will send the uplink payload with Unix timestamp. With the limitation of 11 bytes (max distance of AU915/US915/AS923 band), the time stamp mode will be lack of BAT voltage field, instead, it shows the battery status. The payload is as below:
300 300  
301 -(% border="1" style="background-color:#ffffcc; color:green; width:468px" %)
306 +(% border="1" style="background-color:#ffffcc; color:green; width:510px" %)
302 302  |(% style="width:96px" %)(((
303 303  **Size(bytes)**
304 304  )))|(% style="width:71px" %)(((
... ... @@ -485,7 +485,7 @@
485 485  **Retrieval data payload**
486 486  )))
487 487  
488 -(% border="1" style="background-color:#ffffcc; color:green; width:469px" %)
493 +(% border="1" style="background-color:#ffffcc; color:green; width:510px" %)
489 489  |(% style="width:93px" %)(((
490 490  (((
491 491  **Size(bytes)**
... ... @@ -798,14 +798,24 @@
798 798  
799 799  [[image:image-20220523150701-2.png]]
800 800  
806 +(((
801 801  **Downlink Command: 0x01**
808 +)))
802 802  
810 +(((
803 803  Format: Command Code (0x01) followed by 3 bytes time value.
812 +)))
804 804  
814 +(((
805 805  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
816 +)))
806 806  
807 -* **Example 1**: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
808 -* **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
818 +* (((
819 +**Example 1**: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
820 +)))
821 +* (((
822 +**Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
823 +)))
809 809  
810 810  == 4.2 Set External Sensor Mode ==
811 811  
... ... @@ -815,15 +815,27 @@
815 815  
816 816  [[image:image-20220523150759-3.png]]
817 817  
833 +(((
818 818  **Downlink Command: 0xA2**
835 +)))
819 819  
837 +(((
820 820  Total bytes: 2 ~~ 5 bytes
839 +)))
821 821  
841 +(((
822 822  **Example:**
843 +)))
823 823  
824 -* 0xA201: Set external sensor type to E1
825 -* 0xA209: Same as AT+EXT=9
826 -* 0xA20702003c,Same as AT+SETCNT=60
845 +* (((
846 +0xA201: Set external sensor type to E1
847 +)))
848 +* (((
849 +0xA209: Same as AT+EXT=9
850 +)))
851 +* (((
852 +0xA20702003c,Same as AT+SETCNT=60
853 +)))
827 827  
828 828  == 4.3 Enable/Disable uplink Temperature probe ID ==
829 829  
... ... @@ -851,9 +851,13 @@
851 851  
852 852  [[image:image-20220523151052-5.png]]
853 853  
881 +(((
854 854  **Downlink Command:**
883 +)))
855 855  
885 +(((
856 856  No downlink command for this feature.
887 +)))
857 857  
858 858  == 4.5 Quit AT Command ==
859 859  
... ... @@ -893,11 +893,17 @@
893 893  
894 894  == 4.8 Set Time Sync Mode ==
895 895  
927 +(((
896 896  Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply this command.
929 +)))
897 897  
931 +(((
898 898  SYNCMOD is set to 1 by default. If user want to set a different time from LoRaWAN server, user need to set this to 0.
933 +)))
899 899  
935 +(((
900 900  **AT Command:**
937 +)))
901 901  
902 902  [[image:image-20220523151336-9.png]]
903 903  
... ... @@ -987,7 +987,7 @@
987 987  = 6. Order Info =
988 988  
989 989  (((
990 -Part Number: (% style="color:#4f81bd" %)** LHT65N-XX**
1027 +Part Number: (% style="color:#4f81bd" %)** LHT65N-XX-YY**
991 991  )))
992 992  
993 993  (((