Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,6 +6,11 @@ 6 6 7 7 8 8 9 + 10 + 11 + 12 + 13 + 9 9 **Table of Contents:** 10 10 11 11 {{toc/}} ... ... @@ -298,7 +298,7 @@ 298 298 299 299 Timestamp mode is designed for LHT65N with E3 probe, it will send the uplink payload with Unix timestamp. With the limitation of 11 bytes (max distance of AU915/US915/AS923 band), the time stamp mode will be lack of BAT voltage field, instead, it shows the battery status. The payload is as below: 300 300 301 -(% border="1" style="background-color:#ffffcc; color:green; width: 468px" %)306 +(% border="1" style="background-color:#ffffcc; color:green; width:510px" %) 302 302 |(% style="width:96px" %)((( 303 303 **Size(bytes)** 304 304 )))|(% style="width:71px" %)((( ... ... @@ -485,7 +485,7 @@ 485 485 **Retrieval data payload** 486 486 ))) 487 487 488 -(% border="1" style="background-color:#ffffcc; color:green; width: 469px" %)493 +(% border="1" style="background-color:#ffffcc; color:green; width:510px" %) 489 489 |(% style="width:93px" %)((( 490 490 ((( 491 491 **Size(bytes)** ... ... @@ -798,14 +798,24 @@ 798 798 799 799 [[image:image-20220523150701-2.png]] 800 800 806 +((( 801 801 **Downlink Command: 0x01** 808 +))) 802 802 810 +((( 803 803 Format: Command Code (0x01) followed by 3 bytes time value. 812 +))) 804 804 814 +((( 805 805 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 816 +))) 806 806 807 -* **Example 1**: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 808 -* **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 818 +* ((( 819 +**Example 1**: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 820 +))) 821 +* ((( 822 +**Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 823 +))) 809 809 810 810 == 4.2 Set External Sensor Mode == 811 811 ... ... @@ -815,15 +815,27 @@ 815 815 816 816 [[image:image-20220523150759-3.png]] 817 817 833 +((( 818 818 **Downlink Command: 0xA2** 835 +))) 819 819 837 +((( 820 820 Total bytes: 2 ~~ 5 bytes 839 +))) 821 821 841 +((( 822 822 **Example:** 843 +))) 823 823 824 -* 0xA201: Set external sensor type to E1 825 -* 0xA209: Same as AT+EXT=9 826 -* 0xA20702003c,Same as AT+SETCNT=60 845 +* ((( 846 +0xA201: Set external sensor type to E1 847 +))) 848 +* ((( 849 +0xA209: Same as AT+EXT=9 850 +))) 851 +* ((( 852 +0xA20702003c,Same as AT+SETCNT=60 853 +))) 827 827 828 828 == 4.3 Enable/Disable uplink Temperature probe ID == 829 829 ... ... @@ -851,9 +851,13 @@ 851 851 852 852 [[image:image-20220523151052-5.png]] 853 853 881 +((( 854 854 **Downlink Command:** 883 +))) 855 855 885 +((( 856 856 No downlink command for this feature. 887 +))) 857 857 858 858 == 4.5 Quit AT Command == 859 859 ... ... @@ -893,11 +893,17 @@ 893 893 894 894 == 4.8 Set Time Sync Mode == 895 895 927 +((( 896 896 Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply this command. 929 +))) 897 897 931 +((( 898 898 SYNCMOD is set to 1 by default. If user want to set a different time from LoRaWAN server, user need to set this to 0. 933 +))) 899 899 935 +((( 900 900 **AT Command:** 937 +))) 901 901 902 902 [[image:image-20220523151336-9.png]] 903 903 ... ... @@ -987,7 +987,7 @@ 987 987 = 6. Order Info = 988 988 989 989 ((( 990 -Part Number: (% style="color:#4f81bd" %)** LHT65N-XX** 1027 +Part Number: (% style="color:#4f81bd" %)** LHT65N-XX-YY** 991 991 ))) 992 992 993 993 (((