Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -485,51 +485,81 @@ 485 485 **Retrieval data payload** 486 486 ))) 487 487 488 -(% border="1" style="background-color:#ffffcc; color:green; width: 545px" %)488 +(% border="1" style="background-color:#ffffcc; color:green; width:469px" %) 489 489 |(% style="width:93px" %)((( 490 +((( 490 490 **Size(bytes)** 492 +))) 491 491 )))|(% style="width:71px" %)((( 494 +((( 492 492 **2** 496 +))) 493 493 )))|(% style="width:102px" %)((( 498 +((( 494 494 **2** 500 +))) 495 495 )))|(% style="width:86px" %)((( 502 +((( 496 496 **2** 497 -)))|(% style="width:90px" %)((( 504 +))) 505 +)))|(% style="width:86px" %)((( 506 +((( 498 498 **1** 499 -)))|(% style="width:85px" %)((( 508 +))) 509 +)))|(% style="width:48px" %)((( 510 +((( 500 500 **4** 501 501 ))) 513 +))) 502 502 |(% style="width:93px" %)((( 515 +((( 503 503 **Value** 517 +))) 504 504 )))|(% style="width:71px" %)((( 519 +((( 505 505 [[External sensor data>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.6Extvalue]] 521 +))) 506 506 )))|(% style="width:102px" %)((( 507 507 ((( 524 +((( 508 508 [[Built In>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]] 509 509 ))) 527 +))) 510 510 511 511 ((( 530 +((( 512 512 [[Temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]] 513 513 ))) 533 +))) 514 514 )))|(% style="width:86px" %)((( 515 515 ((( 536 +((( 516 516 [[Built-in>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]] 517 517 ))) 539 +))) 518 518 519 519 ((( 542 +((( 520 520 [[Humidity>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]] 521 521 ))) 522 -)))|(% style="width:90px" %)((( 545 +))) 546 +)))|(% style="width:86px" %)((( 547 +((( 523 523 [[Poll message flag & Ext>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.6.4DatalogUplinkpayload]] 524 -)))|(% style="width:85px" %)((( 549 +))) 550 +)))|(% style="width:48px" %)((( 525 525 ((( 552 +((( 526 526 [[Unix Time Stamp>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.6.1UnixTimeStamp]] 527 527 ))) 555 +))) 528 528 529 529 ((( 558 +((( 530 530 531 531 ))) 532 532 ))) 562 +))) 533 533 534 534 **Poll message flag & Ext** 535 535 ... ... @@ -595,14 +595,25 @@ 595 595 596 596 [[image:image-20220523144455-1.png||height="335" width="735"]] 597 597 628 +((( 598 598 If user sends below downlink command: (% style="background-color:yellow" %)3160065F9760066DA705 630 +))) 599 599 632 +((( 600 600 Where : Start time: 60065F97 = time 21/1/19 04:27:03 634 +))) 601 601 636 +((( 602 602 Stop time 60066DA7= time 21/1/19 05:27:03 638 +))) 603 603 640 +((( 641 + 642 +))) 604 604 644 +((( 605 605 LHT65N will uplink this payload. 646 +))) 606 606 607 607 [[image:image-20220523001219-13.png||height="421" width="727"]] 608 608 ... ... @@ -626,19 +626,27 @@ 626 626 627 627 Alarm mode feature is added since firmware v1.5. When device is in Alarm mode, it will check the built-in sensor temperature in a short interval. If the temperature exceeds the pre-configure range, it will send an uplink immediately. 628 628 670 +((( 629 629 (% style="color:red" %)Note: Alarm mode will increase a little big the power consumption, we recommend extending the normal reading time when enabling this feature. 672 +))) 630 630 674 +((( 631 631 **AT Commands for Alarm mode:** 676 +))) 632 632 633 633 (% class="box infomessage" %) 634 634 ((( 680 +((( 635 635 **AT+WMOD=1**: Enable/Disable Alarm Mode. (0:Disable, 1: Enable) 636 636 ))) 683 +))) 637 637 638 638 (% class="box infomessage" %) 639 639 ((( 687 +((( 640 640 **AT+CITEMP=1**: The interval to check the temperature for Alarm. (Unit: minute) 641 641 ))) 690 +))) 642 642 643 643 == 2.8 LED Indicator == 644 644