Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -561,10 +561,14 @@ 561 561 (% border="1" style="background-color:#ffffcc; color:green; width:540px" %) 562 562 |(% style="width:81px" %)**Bits**|(% style="width:100px" %)**7**|(% style="width:105px" %)**6**|(% style="width:84px" %)**5**|(% style="width:85px" %)**4**|(% style="width:79px" %)**[3:0]** 563 563 |(% style="width:81px" %)**Status & Ext**|(% style="width:100px" %)Not Defined|(% style="width:105px" %)Poll Message Flag|(% style="width:84px" %)Sync time OK|(% style="width:85px" %)Unix Time Request|(% style="width:79px" %)((( 564 +((( 564 564 Ext: 566 +))) 565 565 568 +((( 566 566 0b(1001) 567 567 ))) 571 +))) 568 568 569 569 ((( 570 570 Poll Message Flag: 1: This message is a poll message reply. ... ... @@ -608,17 +608,6 @@ 608 608 609 609 [[image:image-20220523144455-1.png||height="335" width="735"]] 610 610 611 -(% border="1" style="background-color:#ffffcc; color:green; width:709px" %) 612 -|(% style="width:89px" %)Flash Addr|(% style="width:136px" %)Unix Time|(% style="width:39px" %)Ext|(% style="width:97px" %)BAT voltage|(% style="width:344px" %)Value 613 -|(% style="width:89px" %)80196E0|(% style="width:136px" %)21/1/19 04:27:03|(% style="width:39px" %)1|(% style="width:97px" %)3145|(% style="width:344px" %)sht_temp=22.00 sht_hum=32.6 ds_temp=327.67 614 -|(% style="width:89px" %)80196F0|(% style="width:136px" %)21/1/19 04:28:57|(% style="width:39px" %)1|(% style="width:97px" %)3145|(% style="width:344px" %)sht_temp=21.90 sht_hum=33.1 ds_temp=327.67 615 -|(% style="width:89px" %)8019700|(% style="width:136px" %)21/1/19 04:30:30|(% style="width:39px" %)1|(% style="width:97px" %)3145|(% style="width:344px" %)sht_temp=21.81 sht_hum=33.4 ds_temp=327.67 616 -|(% style="width:89px" %)8019710|(% style="width:136px" %)21/1/19 04:40:30|(% style="width:39px" %)1|(% style="width:97px" %)3145|(% style="width:344px" %)sht_temp=21.65 sht_hum=33.7 ds_temp=327.67 617 -|(% style="width:89px" %)8019720|(% style="width:136px" %)21/1/19 04:50:30|(% style="width:39px" %)1|(% style="width:97px" %)3147|(% style="width:344px" %)sht_temp=21.55 sht_hum=34.1 ds_temp=327.67 618 -|(% style="width:89px" %)8019730|(% style="width:136px" %)21/1/19 05:00:30|(% style="width:39px" %)1|(% style="width:97px" %)3149|(% style="width:344px" %)sht_temp=21.50 sht_hum=34.1 ds_temp=327.67 619 -|(% style="width:89px" %)8019740|(% style="width:136px" %)21/1/19 05:10:30|(% style="width:39px" %)1|(% style="width:97px" %)3149|(% style="width:344px" %)sht_temp=21.43 sht_hum=34.6 ds_temp=327.67 620 -|(% style="width:89px" %)8019750|(% style="width:136px" %)21/1/19 05:20:30|(% style="width:39px" %)1|(% style="width:97px" %)3151|(% style="width:344px" %)sht_temp=21.35 sht_hum=34.9 ds_temp=327.67 621 - 622 622 If user sends below downlink command: (% style="background-color:yellow" %)3160065F9760066DA705 623 623 624 624 Where : Start time: 60065F97 = time 21/1/19 04:27:03 ... ... @@ -646,35 +646,50 @@ 646 646 647 647 Unix time is 0x60065F97=1611030423s=21/1/19 04:27:03 648 648 649 - 650 650 == 2.7 Alarm Mode == 651 651 652 652 Alarm mode feature is added since firmware v1.5. When device is in Alarm mode, it will check the built-in sensor temperature in a short interval. If the temperature exceeds the pre-configure range, it will send an uplink immediately. 653 653 646 +(% style="color:red" %)Note: Alarm mode will increase a little big the power consumption, we recommend extending the normal reading time when enabling this feature. 654 654 655 - Note:Alarmmode will increase a little big the power consumption, we recommendextending the normalreadingtimewhen enabling this feature.648 +**AT Commands for Alarm mode:** 656 656 657 - 658 -AT Commands for Alarm mode: 659 - 650 +(% class="box infomessage" %) 651 +((( 660 660 **AT+WMOD=1**: Enable/Disable Alarm Mode. (0:Disable, 1: Enable) 653 +))) 661 661 655 +(% class="box infomessage" %) 656 +((( 662 662 **AT+CITEMP=1**: The interval to check the temperature for Alarm. (Unit: minute) 658 +))) 663 663 664 - 665 - 666 666 == 2.8 LED Indicator == 667 667 662 +((( 668 668 The LHT65N has a triple color LED which for easy shows different stage. 664 +))) 669 669 666 +((( 670 670 While pressing ACT button, the LED will work as per LED status with ACT button. 668 +))) 671 671 670 +((( 672 672 In a normal working state: 672 +))) 673 673 674 -* For each uplink, the BLUE LED or RED LED will blink once. 675 -* BLUE LED when an external sensor is connected 676 -* RED LED when an external sensor is not connected 677 -* For each success downlink, the PURPLE LED will blink once 674 +* ((( 675 +For each uplink, the BLUE LED or RED LED will blink once. 676 +))) 677 +* ((( 678 +BLUE LED when an external sensor is connected 679 +))) 680 +* ((( 681 +RED LED when an external sensor is not connected 682 +))) 683 +* ((( 684 +For each success downlink, the PURPLE LED will blink once 685 +))) 678 678 679 679 ---- 680 680 ... ... @@ -709,7 +709,7 @@ 709 709 710 710 There are two kinds of commands to configure LHT65N, they are: 711 711 712 -* **General Commands**. 720 +(% style="color:#4f81bd" %)* **General Commands**. 713 713 714 714 These commands are to configure: 715 715 ... ... @@ -720,7 +720,7 @@ 720 720 721 721 [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]] 722 722 723 -* **Commands special design for LHT65N** 731 +(% style="color:#4f81bd" %)* **Commands special design for LHT65N** 724 724 725 725 These commands are only valid for LHT65N, as below: 726 726