... ... @@ -507,48 +507,103 @@
507 507  The Datalog poll reply uplink will use below payload format.
508 508  
509 509  (((
510 -Retrieval data payload
510 +**Retrieval data payload**
511 511  )))
512 512  
513 -(% border="1" style="background-color:#ffffcc; color:green; width:615px" %)
514 -|(% style="width:94px" %)**Size(bytes)**|(% style="width:106px" %)**2**|(% style="width:132px" %)**2**|(% style="width:62px" %)**2**|(% style="width:98px" %)**1**|(% style="width:83px" %)**4**
515 -|(% style="width:94px" %)**Value**|(% style="width:106px" %)[[External sensor data>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.6Extvalue]]|(% style="width:132px" %)(((
516 -[[Built-In Temperature >>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
517 -)))|(% style="width:62px" %)(((
518 -[[Built-in>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]][[ Humidity>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
519 -)))|(% style="width:98px" %)[[Poll message flag & Ext>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.6.4DatalogUplinkpayload]]|(% style="width:83px" %)(((
513 +(% border="1" style="background-color:#ffffcc; color:green; width:545px" %)
514 +|(% style="width:93px" %)(((
515 +**Size(bytes)**
516 +)))|(% style="width:71px" %)(((
517 +**2**
518 +)))|(% style="width:102px" %)(((
519 +**2**
520 +)))|(% style="width:86px" %)(((
521 +**2**
522 +)))|(% style="width:90px" %)(((
523 +**1**
524 +)))|(% style="width:85px" %)(((
525 +**4**
526 +)))
527 +|(% style="width:93px" %)(((
528 +**Value**
529 +)))|(% style="width:71px" %)(((
530 +[[External sensor data>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.6Extvalue]]
531 +)))|(% style="width:102px" %)(((
532 +(((
533 +[[Built In>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
534 +)))
535 +
536 +(((
537 +[[Temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
538 +)))
539 +)))|(% style="width:86px" %)(((
540 +(((
541 +[[Built-in>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
542 +)))
543 +
544 +(((
545 +[[Humidity>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
546 +)))
547 +)))|(% style="width:90px" %)(((
548 +[[Poll message flag & Ext>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.6.4DatalogUplinkpayload]]
549 +)))|(% style="width:85px" %)(((
550 +(((
520 520  [[Unix Time Stamp>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.6.1UnixTimeStamp]]
552 +)))
521 521  
554 +(((
522 522  
523 523  )))
557 +)))
524 524  
525 -Poll message flag & Ext
559 +**Poll message flag & Ext**
526 526  
527 -
528 -(% border="1" style="background-color:#ffffcc; color:green; width:542px" %)
529 -|(% style="width:81px" %)**Bits**|(% style="width:100px" %)**7**|(% style="width:114px" %)**6**|(% style="width:85px" %)**5**|(% style="width:85px" %)**4**|(% style="width:77px" %)**[3:0]**
530 -|(% style="width:81px" %)**Status & Ext**|(% style="width:100px" %)Not Defined|(% style="width:114px" %)Poll Message Flag|(% style="width:85px" %)Sync time OK|(% style="width:85px" %)Unix Time Request|(% style="width:77px" %)(((
561 +(% border="1" style="background-color:#ffffcc; color:green; width:540px" %)
562 +|(% style="width:81px" %)**Bits**|(% style="width:100px" %)**7**|(% style="width:105px" %)**6**|(% style="width:84px" %)**5**|(% style="width:85px" %)**4**|(% style="width:79px" %)**[3:0]**
563 +|(% style="width:81px" %)**Status & Ext**|(% style="width:100px" %)Not Defined|(% style="width:105px" %)Poll Message Flag|(% style="width:84px" %)Sync time OK|(% style="width:85px" %)Unix Time Request|(% style="width:79px" %)(((
564 +(((
531 531  Ext:
566 +)))
532 532  
568 +(((
533 533  0b(1001)
534 534  )))
571 +)))
535 535  
573 +(((
536 536  Poll Message Flag: 1: This message is a poll message reply.
575 +)))
537 537  
538 -* Poll Message Flag is set to 1.
539 -* Each data entry is 11 bytes, to save airtime and battery, devices will send max bytes according to the current DR and Frequency bands.
577 +* (((
578 +Poll Message Flag is set to 1.
579 +)))
580 +* (((
581 +Each data entry is 11 bytes, to save airtime and battery, devices will send max bytes according to the current DR and Frequency bands.
582 +)))
540 540  
584 +(((
541 541  For example, in US915 band, the max payload for different DR is:
586 +)))
542 542  
543 -a)      DR0: max is 11 bytes so one entry of data
588 +(((
589 +a) DR0: max is 11 bytes so one entry of data
590 +)))
544 544  
545 -b)      DR1: max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)
592 +(((
593 +b) DR1: max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)
594 +)))
546 546  
547 -c)      DR2: total payload includes 11 entries of data
596 +(((
597 +c) DR2: total payload includes 11 entries of data
598 +)))
548 548  
549 -d)      DR3: total payload includes 22 entries of data.
600 +(((
601 +d) DR3: total payload includes 22 entries of data.
602 +)))
550 550  
604 +(((
551 551  If devise doesn’t have any data in the polling time. Device will uplink 11 bytes of 0   
606 +)))
552 552  
553 553  
554 554  **Example:**
... ... @@ -555,29 +555,10 @@
555 555  
556 556  If LHT65N has below data inside Flash:
557 557  
558 -Flash Addr   |Unix Time | Ext | BAT voltage|  Value                  
613 +[[image:image-20220523144455-1.png||height="335" width="735"]]
559 559  
560 -80196E0 21/1/19 04:27:03 1 3145 sht_temp=22.00 sht_hum=32.6 ds_temp=327.67
615 +If user sends below downlink command: (% style="background-color:yellow" %)3160065F9760066DA705
561 561  
562 -80196F0 21/1/19 04:28:57 1 3145 sht_temp=21.90 sht_hum=33.1 ds_temp=327.67
563 -
564 -8019700 21/1/19 04:30:30 1 3145 sht_temp=21.81 sht_hum=33.4 ds_temp=327.67
565 -
566 -8019710 21/1/19 04:40:30 1 3145 sht_temp=21.65 sht_hum=33.7 ds_temp=327.67
567 -
568 -8019720 21/1/19 04:50:30 1 3147 sht_temp=21.55 sht_hum=34.1 ds_temp=327.67
569 -
570 -8019730 21/1/19 05:00:30 1 3149 sht_temp=21.50 sht_hum=34.1 ds_temp=327.67
571 -
572 -8019740 21/1/19 05:10:30 1 3149 sht_temp=21.43 sht_hum=34.6 ds_temp=327.67
573 -
574 -8019750 21/1/19 05:20:30 1 3151 sht_temp=21.35 sht_hum=34.9 ds_temp=327.67
575 -
576 -
577 -If user sends below downlink command:
578 -
579 -3160065F9760066DA705
580 -
581 581   Where : Start time: 60065F97 = time 21/1/19 04:27:03
582 582  
583 583   Stop time 60066DA7= time 21/1/19 05:27:03
... ... @@ -603,35 +603,50 @@
603 603  
604 604  Unix time is 0x60065F97=1611030423s=21/1/19 04:27:03
605 605  
606 -
607 607  == 2.7 Alarm Mode ==
608 608  
609 609  Alarm mode feature is added since firmware v1.5. When device is in Alarm mode, it will check the built-in sensor temperature in a short interval. If the temperature exceeds the pre-configure range, it will send an uplink immediately.
610 610  
646 +(% style="color:red" %)Note: Alarm mode will increase a little big the power consumption, we recommend extending the normal reading time when enabling this feature.
611 611  
612 -Note: Alarm mode will increase a little big the power consumption, we recommend extending the normal reading time when enabling this feature.
648 +**AT Commands for Alarm mode:**
613 613  
614 -
615 -AT Commands for Alarm mode:
616 -
650 +(% class="box infomessage" %)
651 +(((
617 617  **AT+WMOD=1**: Enable/Disable Alarm Mode. (0:Disable, 1: Enable)
653 +)))
618 618  
655 +(% class="box infomessage" %)
656 +(((
619 619  **AT+CITEMP=1**: The interval to check the temperature for Alarm. (Unit: minute)
658 +)))
620 620  
621 -
622 -
623 623  == 2.8 LED Indicator ==
624 624  
662 +(((
625 625  The LHT65N has a triple color LED which for easy shows different stage.
664 +)))
626 626  
666 +(((
627 627  While pressing ACT button, the LED will work as per LED status with ACT button.
668 +)))
628 628  
670 +(((
629 629  In a normal working state:
672 +)))
630 630  
631 -* For each uplink, the BLUE LED or RED LED will blink once.
632 -* BLUE LED when an external sensor is connected
633 -* RED LED when an external sensor is not connected
634 -* For each success downlink, the PURPLE LED will blink once
674 +* (((
675 +For each uplink, the BLUE LED or RED LED will blink once.
676 +)))
677 +* (((
678 +BLUE LED when an external sensor is connected
679 +)))
680 +* (((
681 +RED LED when an external sensor is not connected
682 +)))
683 +* (((
684 +For each success downlink, the PURPLE LED will blink once
685 +)))
635 635  
636 636  ----
637 637  
... ... @@ -666,7 +666,7 @@
666 666  
667 667  There are two kinds of commands to configure LHT65N, they are:
668 668  
669 -* **General Commands**.
720 +(% style="color:#4f81bd" %)* **General Commands**.
670 670  
671 671  These commands are to configure:
672 672  
... ... @@ -677,7 +677,7 @@
677 677  
678 678  [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]]
679 679  
680 -* **Commands special design for LHT65N**
731 +(% style="color:#4f81bd" %)* **Commands special design for LHT65N**
681 681  
682 682  These commands are only valid for LHT65N, as below:
683 683  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved