<
From version < 57.6 >
edited by Xiaoling
on 2022/05/23 14:04
To version < 57.4 >
edited by Xiaoling
on 2022/05/23 13:52
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -163,8 +163,10 @@
163 163  
164 164  [[image:image-20220522232916-3.png]]
165 165  
166 +
166 166  [[image:image-20220522232932-4.png]]
167 167  
169 +
168 168  [[image:image-20220522232954-5.png]]
169 169  
170 170  Note: LHT65N use same payload as LHT65.
... ... @@ -191,7 +191,7 @@
191 191  After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once.
192 192  
193 193  
194 -(% border="1" style="background-color:#ffffcc; color:green; width:605px" %)
196 +(% border="1" style="width:605px" %)
195 195  |(% style="width:106px" %)**Size(bytes)**|(% style="width:71px" %)**2**|(% style="width:183px" %)**2**|(% style="width:155.172px" %)**2**|(% style="width:49px" %)**1**|(% style="width:92px" %)**4**
196 196  |(% style="width:106px" %)**Value**|(% style="width:71px" %)[[BAT>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.2BAT-BatteryInfo]]|(% style="width:183px" %)(((
197 197  [[Built In Temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
... ... @@ -217,7 +217,7 @@
217 217  
218 218  These two bytes of BAT include the battery state and the actually voltage
219 219  
220 -(% border="1" style="background-color:#ffffcc; color:green; width:508px" %)
222 +(% border="1" style="width:508px" %)
221 221  |(% style="width:75px" %)Bit(bit)|(% style="width:268px" %)[15:14]|(% style="width:162px" %)[13:0]
222 222  |(% style="width:75px" %)Value|(% style="width:268px" %)(((
223 223  BAT Status
... ... @@ -231,7 +231,7 @@
231 231  11(b): Good   (BAT >= 2.65v)
232 232  )))|(% style="width:162px" %)Actually BAT voltage
233 233  
234 -[[image:image-20220522235639-1.png||height="139" width="727"]]
236 +[[image:image-20220522235639-1.png]]
235 235  
236 236  Check the battery voltage for LHT65N.
237 237  
... ... @@ -240,7 +240,7 @@
240 240  
241 241  === 2.4.3 Built-in Temperature ===
242 242  
243 -[[image:image-20220522235639-2.png||height="138" width="722"]]
245 +[[image:image-20220522235639-2.png]]
244 244  
245 245  * Temperature:  0x0ABB/100=27.47℃
246 246  
... ... @@ -250,7 +250,7 @@
250 250  
251 251  === 2.4.4 Built-in Humidity ===
252 252  
253 -[[image:image-20220522235639-4.png||height="138" width="722"]]
255 +[[image:image-20220522235639-4.png]]
254 254  
255 255  * Humidity:    0x025C/10=60.4%
256 256  
... ... @@ -258,10 +258,10 @@
258 258  
259 259  Bytes for External Sensor:
260 260  
261 -(% border="1" style="background-color:#ffffcc; color:green; width:473px" %)
262 -|(% style="width:139px" %)**EXT # Value**|(% style="width:331px" %)**External Sensor Type**
263 -|(% style="width:139px" %)0x01|(% style="width:331px" %)Sensor E3, Temperature Sensor
264 -|(% style="width:139px" %)0x09|(% style="width:331px" %)Sensor E3, Temperature Sensor, Datalog Mod
263 +(% style="width:624px" %)
264 +|(% style="width:139px" %)**EXT # Value**|(% style="width:484px" %)**External Sensor Type**
265 +|(% style="width:139px" %)0x01|(% style="width:484px" %)Sensor E3, Temperature Sensor
266 +|(% style="width:139px" %)0x09|(% style="width:484px" %)Sensor E3, Temperature Sensor, Datalog Mod
265 265  
266 266  === 2.4.6 Ext value ===
267 267  
... ... @@ -277,13 +277,9 @@
277 277  
278 278  * External temperature= (0xF54F-65536)/100=-27.37℃
279 279  
280 -(((
281 281  The last 2 bytes of data are meaningless
282 -)))
283 283  
284 -(((
285 285  If the external sensor is 0x01, and there is no external temperature connected. The temperature will be set to 7FFF which is 327.67℃
286 -)))
287 287  
288 288  
289 289  ==== 2.4.6.2 Ext~=9, E3 sensor with Unix Timestamp ====
... ... @@ -290,27 +290,28 @@
290 290  
291 291  Timestamp mode is designed for LHT65N with E3 probe, it will send the uplink payload with Unix timestamp. With the limitation of 11 bytes (max distance of AU915/US915/AS923 band), the time stamp mode will be lack of BAT voltage field, instead, it shows the battery status. The payload is as below:
292 292  
293 -(% border="1" style="background-color:#ffffcc; color:green; width:697px" %)
291 +
292 +(% border="1" style="width:697px" %)
294 294  |(% style="width:96px" %)**Size(bytes)**|(% style="width:164px" %)**2**|(% style="width:104px" %)**2**|(% style="width:106px" %)**2**|(% style="width:108px" %)**1**|(% style="width:116px" %)**4**
295 -|(% style="width:96px" %)**Value**|(% style="width:164px" %)[[External temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.2SetExternalSensorMode]]|(% style="width:104px" %)(((
296 -[[Built-In>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
294 +|(% style="width:96px" %)**Value**|(% style="width:164px" %)[[External temperature>>path:#DS18b20_value]]|(% style="width:104px" %)(((
295 +[[Built-In>>path:#SHT20_Temperature]]
297 297  
298 -[[Temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
297 +[[Temperature>>path:#SHT20_Temperature]]
299 299  )))|(% style="width:106px" %)(((
300 -BAT Status &
299 +[[BAT Status &>>path:#BAT_Humidity]]
301 301  
302 -[[Built-in>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
301 +[[Built-in>>path:#BAT_Humidity]]
303 303  
304 -[[Humidity>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
305 -)))|(% style="width:108px" %)Status & Ext|(% style="width:116px" %)(((
306 -[[Unix>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.1SetTransmitIntervalTime]]
303 +[[Humidity>>path:#BAT_Humidity]]
304 +)))|(% style="width:108px" %)[[Status & Ext>>path:#Status_EXT]]|(% style="width:116px" %)(((
305 +[[Unix>>path:#Unix_Time_Stamp]]
307 307  
308 -[[Time Stamp>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.1SetTransmitIntervalTime]]
307 +[[Time Stamp>>path:#Unix_Time_Stamp]]
309 309  )))
310 310  
311 -* **Battery status & (% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)Built-in Humidity(%%)**
310 +* **Battery status & **[[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)**Built-in Humidity**>>path:#SHT20_Humidity]]
312 312  
313 -(% border="1" style="background-color:#ffffcc; color:green; width:587px" %)
312 +(% border="1" style="width:587px" %)
314 314  |Bit(bit)|(% style="width:280px" %)[15:14]|(% style="width:136px" %)[11:0]
315 315  |Value|(% style="width:280px" %)(((
316 316  BAT Status
... ... @@ -323,7 +323,7 @@
323 323  
324 324  11(b): Good   (BAT >= 2.65v)
325 325  )))|(% style="width:136px" %)(((
326 -[[Built-in Humidity>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
325 +[[Built-in Humidity>>path:#SHT20_Humidity]]
327 327  
328 328  
329 329  )))
... ... @@ -330,10 +330,12 @@
330 330  
331 331  * **Status & Ext Byte**
332 332  
333 -(% border="1" style="background-color:#ffffcc; color:green; width:732px" %)
332 +(% border="1" style="width:732px" %)
334 334  |(% style="width:128px" %)**Bits**|(% style="width:102px" %)**7**|(% style="width:145px" %)**6**|(% style="width:117px" %)**5**|(% style="width:147px" %)**4**|(% style="width:90px" %)**[3:0]**
335 335  |(% style="width:128px" %)**Status & Ext**|(% style="width:102px" %)Not Defined|(% style="width:145px" %)Poll Message Flag|(% style="width:117px" %)Sync time OK|(% style="width:147px" %)Unix Time Request|(% style="width:90px" %)(((
336 -Ext:0b(1001)
335 +Ext:
336 +
337 +0b(1001)
337 337  )))
338 338  
339 339  * Poll Message Flag: 1: This message is a poll message reply, 0: means this is a normal uplink.
... ... @@ -344,17 +344,12 @@
344 344  
345 345  Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
346 346  
347 -(((
348 348  **Step 1**: Be sure that your device is programmed and properly connected to the LoRaWAN network.
349 -)))
350 350  
351 -(((
352 352  **Step 2**: Configure your Application to forward data to Datacake you will need to add integration. Go to TTN V3 Console ~-~-> Applications ~-~-> Integrations ~-~-> Add Integrations.
353 -)))
354 354  
355 -(((
352 +
356 356  Add Datacake:
357 -)))
358 358  
359 359  [[image:image-20220523000825-7.png||height="262" width="583"]]
360 360  
... ... @@ -363,12 +363,16 @@
363 363  
364 364  [[image:image-20220523000825-8.png||height="453" width="406"]]
365 365  
362 +
366 366  In Datacake console ([[https:~~/~~/datacake.co/>>url:https://datacake.co/]]) , add LHT65 device.
367 367  
368 368  [[image:image-20220523000825-9.png||height="366" width="392"]]
369 369  
367 +
368 +
370 370  [[image:image-20220523000825-10.png||height="432" width="762"]]
371 371  
371 +
372 372  == 2.6 Datalog Feature ==
373 373  
374 374  This feature is always enabled. When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot.
... ... @@ -380,13 +380,9 @@
380 380  [[image:image-20220523001219-11.png||height="97" width="627"]]
381 381  
382 382  
383 -(((
384 384  User can get this time from link:  [[https:~~/~~/www.epochconverter.com/>>url:https://www.epochconverter.com/]] :
385 -)))
386 386  
387 -(((
388 388  Below is the converter example
389 -)))
390 390  
391 391  [[image:image-20220523001219-12.png||height="302" width="730"]]
392 392  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0