<
From version < 57.5 >
edited by Xiaoling
on 2022/05/23 14:03
To version < 51.1 >
edited by Edwin Chen
on 2022/05/23 00:18
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -1,47 +1,27 @@
1 -(% style="text-align:center" %)
2 -[[image:image-20220523115324-1.jpeg||height="500" width="500"]]
3 -
4 -
5 -**LHT65N LoRaWAN Temperature & Humidity Sensor Manual**
6 -
7 -
8 -
9 -**Table of Contents:**
10 -
1 +{{box cssClass="floatinginfobox" title="**Contents**"}}
11 11  {{toc/}}
3 +{{/box}}
12 12  
5 += Overview =
13 13  
7 +[[image:LHT65N_10.png||alt="LHT65_Image" height="265" width="265"]]
14 14  
15 -= 1.Introduction =
16 16  
17 -== 1.1 What is LHT65N Temperature & Humidity Sensor ==
10 +The Dragino LHT65N Temperature & Humidity sensor is a Long Range LoRaWAN Sensor. It includes a(% class="mark" %) **built-in Temperature & Humidity sensor**(%%) and has an external sensor connector to connect to an external (% class="mark" %)**Temperature Sensor**(%%)**.**
18 18  
19 -(((
20 -The Dragino LHT65N Temperature & Humidity sensor is a Long Range LoRaWAN Sensor. It includes a (% style="color:#4f81bd" %)**built-in Temperature & Humidity sensor**(%%) and has an external sensor connector to connect to an external (% style="color:#4f81bd" %)**Temperature Sensor**(%%)**.**
21 -)))
22 -
23 -(((
24 24  The LHT65N allows users to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, building automation, and so on.
25 -)))
26 26  
27 -(((
28 28  LHT65N has a built-in 2400mAh non-chargeable battery which can be used for up to 10 years*.
29 -)))
30 30  
31 -(((
32 32  LHT65N is full compatible with LoRaWAN v1.0.3 Class A protocol, it can work with a standard LoRaWAN gateway.
33 -)))
34 34  
35 -(((
36 -LHT65N supports (% style="color:#4f81bd" %)**Datalog Feature**(%%). It will record the data when there is no network coverage and users can retrieve the sensor value later to ensure no miss for every sensor reading.
37 -)))
18 +LHT65N supports (% class="mark" %)Datalog Feature(%%). It will record the data when there is no network coverage and users can retrieve the sensor value later to ensure no miss for every sensor reading.
38 38  
39 -(((
40 40  *The actual battery life depends on how often to send data, please see the battery analyzer chapter.
41 -)))
42 42  
43 -== 1.2 Features ==
44 44  
23 +== Features: ==
24 +
45 45  * Wall mountable
46 46  * LoRaWAN v1.0.3 Class A protocol
47 47  * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915
... ... @@ -54,91 +54,55 @@
54 54  * Tri-color LED to indicate working status
55 55  * Datalog feature
56 56  
57 -== 1.3 Specification ==
37 +== Specification: ==
58 58  
59 -(((
60 60  **Built-in Temperature Sensor:**
61 -)))
62 62  
63 -* (((
64 -Resolution: 0.01 °C
65 -)))
66 -* (((
67 -Accuracy Tolerance : Typ ±0.3 °C
68 -)))
69 -* (((
70 -Long Term Drift: < 0.02 °C/yr
71 -)))
72 -* (((
73 -Operating Range: -40 ~~ 85 °C
74 -)))
41 +* Resolution: 0.01 °C
42 +* Accuracy Tolerance : Typ ±0.3 °C
43 +* Long Term Drift: < 0.02 °C/yr
44 +* Operating Range: -40 ~~ 85 °C
75 75  
76 -(((
77 77  **Built-in Humidity Sensor:**
78 -)))
79 79  
80 -* (((
81 -Resolution: 0.04 %RH
82 -)))
83 -* (((
84 -Accuracy Tolerance : Typ ±3 %RH
85 -)))
86 -* (((
87 -Long Term Drift: < 0.02 °C/yr
88 -)))
89 -* (((
90 -Operating Range: 0 ~~ 96 %RH
91 -)))
48 +* Resolution: 0.04 %RH
49 +* Accuracy Tolerance : Typ ±3 %RH
50 +* Long Term Drift: < 0.02 °C/yr
51 +* Operating Range: 0 ~~ 96 %RH
92 92  
93 -(((
94 94  **External Temperature Sensor:**
95 -)))
96 96  
97 -* (((
98 -Resolution: 0.0625 °C
99 -)))
100 -* (((
101 -±0.5°C accuracy from -10°C to +85°C
102 -)))
103 -* (((
104 -±2°C accuracy from -55°C to +125°C
105 -)))
106 -* (((
107 -Operating Range: -55 °C ~~ 125 °C
108 -)))
55 +* Resolution: 0.0625 °C
56 +* ±0.5°C accuracy from -10°C to +85°C
57 +* ±2°C accuracy from -55°C to +125°C
58 +* Operating Range: -55 °C ~~ 125 °C
109 109  
110 -= 2. Connect LHT65N to IoT Server =
60 += Connect LHT65N to IoT Server =
111 111  
112 -== 2.1 How does LHT65N work? ==
62 +== How does LHT65N work? ==
113 113  
114 -(((
115 115  LHT65N is configured as LoRaWAN OTAA Class A mode by default. Each LHT65N is shipped with a worldwide unique set of OTAA keys. To use LHT65N in a LoRaWAN network, first, we need to put the OTAA keys in LoRaWAN Network Server and then activate LHT65N.
116 -)))
117 117  
118 -(((
119 119  If LHT65N is under the coverage of this LoRaWAN network. LHT65N can join the LoRaWAN network automatically. After successfully joining, LHT65N will start to measure environment temperature and humidity, and start to transmit sensor data to the LoRaWAN server. The default period for each uplink is 20 minutes.
120 -)))
121 121  
122 -== 2.2 How to Activate LHT65N? ==
123 123  
69 +== How to Activate LHT65N? ==
70 +
124 124  The LHT65N has two working modes:
125 125  
126 126  * **Deep Sleep Mode**: LHT65N doesn’t have any LoRaWAN activation. This mode is used for storage and shipping to save battery life.
127 127  * **Working Mode**: In this mode, LHT65N works as LoRaWAN Sensor mode to Join LoRaWAN network and send out the sensor data to the server. Between each sampling/tx/rx periodically, LHT65 will be in STOP mode (IDLE mode), in STOP mode, LHT65N has the same power consumption as Deep Sleep mode. 
128 128  
129 -(((
130 130  The LHT65N is set in deep sleep mode by default; The ACT button on the front is to switch to different modes:
131 -)))
132 132  
133 133  [[image:image-20220515123819-1.png||height="379" width="317"]]
134 134  
135 -(% border="1" style="background-color:#ffffcc; color:green; width:739px" %)
136 -|**Behavior on ACT**|**Function**|(% style="width:424px" %)**Action**
137 -|**Pressing ACT between 1s < time < 3s**|Test uplink status|(% style="width:424px" %)If LHT65N is already Joined to the LoRaWAN network, LHT65N will send an uplink packet, if LHT65N has an external sensor connected, blue led will blink once. If LHT65N has no external sensor, red led will blink once.
138 -|**Pressing ACT for more than 3s**|Active Device|(% style="width:424px" %)green led will fast blink 5 times, LHT65N will enter working mode and start to JOIN LoRaWAN network. green led will solid turn on for 5 seconds after join in network.
139 -|**Fast press ACT 5 times**|Deactivate Device|(% style="width:424px" %)red led will solid on for 5 seconds. This means LHT65N is in Deep Sleep Mode.
80 +|**Behavior on ACT**|**Function**|**Action**
81 +|**Pressing ACT between 1s < time < 3s**|Test uplink status|If LHT65N is already Joined to the LoRaWAN network, LHT65N will send an uplink packet, if LHT65N has an external sensor connected, blue led will blink once. If LHT65N has no external sensor, red led will blink once.
82 +|**Pressing ACT for more than 3s**|Active Device|green led will fast blink 5 times, LHT65N will enter working mode and start to JOIN LoRaWAN network. green led will solid turn on for 5 seconds after join in network.
83 +|**Fast press ACT 5 times**|Deactivate Device|red led will solid on for 5 seconds. This means LHT65N is in Deep Sleep Mode.
140 140  
141 -== 2.3 Example to join LoRaWAN network ==
85 +== Example to join LoRaWAN network ==
142 142  
143 143  (% class="wikigeneratedid" %)
144 144  This section shows an example of how to join the TTN V3 LoRaWAN IoT server. Use with other LoRaWAN IoT servers is of a similar procedure.
... ... @@ -149,7 +149,7 @@
149 149  Assume the LPS8N is already set to connect to [[TTN V3 network>>url:https://eu1.cloud.thethings.network]], So it provides network coverage for LHT65N. Next we need to add the LHT65N device in TTN V3:
150 150  
151 151  
152 -=== 2.3.1 Step 1: Create Device n TTN ===
96 +=== **Step 1**: Create Device n TTN ===
153 153  
154 154  Create a device in TTN V3 with the OTAA keys from LHT65N.
155 155  
... ... @@ -163,8 +163,10 @@
163 163  
164 164  [[image:image-20220522232916-3.png]]
165 165  
110 +
166 166  [[image:image-20220522232932-4.png]]
167 167  
113 +
168 168  [[image:image-20220522232954-5.png]]
169 169  
170 170  Note: LHT65N use same payload as LHT65.
... ... @@ -177,33 +177,37 @@
177 177  [[image:image-20220522233118-7.png]]
178 178  
179 179  
180 -=== 2.3.2 Step 2: Activate LHT65N by pressing the ACT button for more than 5 seconds. ===
126 +=== Step 2: Activate LHT65N by pressing the ACT button for more than 5 seconds. ===
181 181  
182 182  Use ACT button to activate LHT65N and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel.
183 183  
184 -[[image:image-20220522233300-8.png||height="219" width="722"]]
130 +[[image:image-20220522233300-8.png]]
185 185  
186 186  
187 -== 2.4 Uplink Payload ==
133 +== Uplink Payload: ==
188 188  
189 -The uplink payload includes totally 11 bytes. Uplink packets use FPORT=2 and (% style="color:#4f81bd" %)**every 20 minutes**(%%) send one uplink by default.
135 +The uplink payload includes totally 11 bytes. Uplink packets use FPORT=2 and(% class="mark" %) every 20 minutes(%%) send one uplink by default.
190 190  
191 -After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once.
137 +After each uplink, the (% class="mark" %)BLUE LED(%%) will blink once.
192 192  
193 193  
194 -(% border="1" style="background-color:#ffffcc; color:green; width:605px" %)
195 -|(% style="width:106px" %)**Size(bytes)**|(% style="width:71px" %)**2**|(% style="width:183px" %)**2**|(% style="width:155.172px" %)**2**|(% style="width:49px" %)**1**|(% style="width:92px" %)**4**
196 -|(% style="width:106px" %)**Value**|(% style="width:71px" %)[[BAT>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.2BAT-BatteryInfo]]|(% style="width:183px" %)(((
197 -[[Built In Temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
198 -)))|(% style="width:155.172px" %)(((
199 -[[Built-in Humidity>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
200 -)))|(% style="width:49px" %)[[Ext>>path:#Extension_Sensor]] #|(% style="width:92px" %)[[Ext value>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.6Extvalue]]
140 +(% style="width:572px" %)
141 +|(% style="width:106px" %)**Size(bytes)**|(% style="width:71px" %)**2**|(% style="width:128px" %)**2**|(% style="width:103px" %)**2**|(% style="width:72px" %)**1**|(% style="width:89px" %)**4**
142 +|(% style="width:106px" %)**Value**|(% style="width:71px" %)[[BAT>>path:#Battery]]|(% style="width:128px" %)(((
143 +[[Built-In>>path:#SHT20_Temperature]]
201 201  
145 +[[Temperature>>path:#SHT20_Temperature]]
146 +)))|(% style="width:103px" %)(((
147 +[[Built-in>>path:#SHT20_Humidity]]
148 +
149 +[[Humidity>>path:#SHT20_Humidity]]
150 +)))|(% style="width:72px" %)[[Ext>>path:#Extension_Sensor]] #|(% style="width:89px" %)[[Ext value>>path:#Extension_sensor_value]]
151 +
202 202  * The First 6 bytes: has fix meanings for every LHT65N.
203 203  * The 7th byte (EXT #): defines the external sensor model.
204 204  * The 8^^th^^ ~~ 11^^th^^ byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won’t be these four bytes.)
205 205  
206 -=== 2.4.1 Decoder in TTN V3 ===
156 +=== Decoder in TTN V3 ===
207 207  
208 208  When the uplink payload arrives TTNv3, it shows HEX format and not friendly to read. We can add LHT65N decoder in TTNv3 for friendly reading.
209 209  
... ... @@ -211,15 +211,16 @@
211 211  
212 212  [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0 >>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]]
213 213  
214 -[[image:image-20220522234118-10.png||height="353" width="729"]]
164 +[[image:image-20220522234118-10.png]]
215 215  
216 -=== 2.4.2 BAT-Battery Info ===
217 217  
167 +=== BAT-Battery Info ===
168 +
218 218  These two bytes of BAT include the battery state and the actually voltage
219 219  
220 -(% border="1" style="background-color:#ffffcc; color:green; width:508px" %)
221 -|(% style="width:75px" %)Bit(bit)|(% style="width:268px" %)[15:14]|(% style="width:162px" %)[13:0]
222 -|(% style="width:75px" %)Value|(% style="width:268px" %)(((
171 +(% style="width:646px" %)
172 +|Bit(bit)|(% style="width:272px" %)[15:14]|(% style="width:214px" %)[13:0]
173 +|Value|(% style="width:272px" %)(((
223 223  BAT Status
224 224  
225 225  00(b): Ultra Low ( BAT <= 2.50v)
... ... @@ -229,9 +229,9 @@
229 229  10(b): OK   (2.55v <= BAT <=2.65v)
230 230  
231 231  11(b): Good   (BAT >= 2.65v)
232 -)))|(% style="width:162px" %)Actually BAT voltage
183 +)))|(% style="width:214px" %)Actually BAT voltage
233 233  
234 -[[image:image-20220522235639-1.png||height="139" width="727"]]
185 +[[image:image-20220522235639-1.png]]
235 235  
236 236  Check the battery voltage for LHT65N.
237 237  
... ... @@ -238,9 +238,9 @@
238 238  * BAT status=(0Xcba4>>14)&0xFF=11(B),very good
239 239  * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV
240 240  
241 -=== 2.4.3 Built-in Temperature ===
192 +=== Built-in Temperature ===
242 242  
243 -[[image:image-20220522235639-2.png||height="138" width="722"]]
194 +[[image:image-20220522235639-2.png]]
244 244  
245 245  * Temperature:  0x0ABB/100=27.47℃
246 246  
... ... @@ -248,70 +248,70 @@
248 248  
249 249  * Temperature:  (0xF5C6-65536)/100=-26.18℃
250 250  
251 -=== 2.4.4 Built-in Humidity ===
202 +=== Built-in Humidity ===
252 252  
253 -[[image:image-20220522235639-4.png||height="138" width="722"]]
204 +[[image:image-20220522235639-4.png]]
254 254  
255 255  * Humidity:    0x025C/10=60.4%
256 256  
257 -=== 2.4.5 Ext # ===
208 +=== Ext # ===
258 258  
259 259  Bytes for External Sensor:
260 260  
261 -(% border="1" style="background-color:#ffffcc; color:green; width:473px" %)
262 -|(% style="width:139px" %)**EXT # Value**|(% style="width:331px" %)**External Sensor Type**
263 -|(% style="width:139px" %)0x01|(% style="width:331px" %)Sensor E3, Temperature Sensor
264 -|(% style="width:139px" %)0x09|(% style="width:331px" %)Sensor E3, Temperature Sensor, Datalog Mod
212 +(% style="width:624px" %)
213 +|(% style="width:139px" %)**EXT # Value**|(% style="width:484px" %)**External Sensor Type**
214 +|(% style="width:139px" %)0x01|(% style="width:484px" %)Sensor E3, Temperature Sensor
215 +|(% style="width:139px" %)0x09|(% style="width:484px" %)Sensor E3, Temperature Sensor, Datalog Mod
265 265  
266 -=== 2.4.6 Ext value ===
217 +=== Ext value ===
267 267  
268 -==== 2.4.6.1 Ext~=1, E3 Temperature Sensor ====
219 +==== Ext~=1, E3 Temperature Sensor ====
269 269  
270 270  [[image:image-20220522235639-5.png]]
271 271  
223 +
272 272  * DS18B20 temp=0x0ADD/100=27.81℃
273 273  
274 274  The last 2 bytes of data are meaningless
275 275  
228 +
229 +
276 276  [[image:image-20220522235639-6.png]]
277 277  
278 278  * External temperature= (0xF54F-65536)/100=-27.37℃
279 279  
280 -(((
281 281  The last 2 bytes of data are meaningless
282 -)))
283 283  
284 -(((
236 +
285 285  If the external sensor is 0x01, and there is no external temperature connected. The temperature will be set to 7FFF which is 327.67℃
286 -)))
287 287  
288 288  
289 -==== 2.4.6.2 Ext~=9, E3 sensor with Unix Timestamp ====
240 +==== Ext~=9, E3 sensor with Unix Timestamp ====
290 290  
291 291  Timestamp mode is designed for LHT65N with E3 probe, it will send the uplink payload with Unix timestamp. With the limitation of 11 bytes (max distance of AU915/US915/AS923 band), the time stamp mode will be lack of BAT voltage field, instead, it shows the battery status. The payload is as below:
292 292  
293 293  
294 -(% border="1" style="background-color:#ffffcc; color:green; width:697px" %)
245 +(% style="width:697px" %)
295 295  |(% style="width:96px" %)**Size(bytes)**|(% style="width:164px" %)**2**|(% style="width:104px" %)**2**|(% style="width:106px" %)**2**|(% style="width:108px" %)**1**|(% style="width:116px" %)**4**
296 -|(% style="width:96px" %)**Value**|(% style="width:164px" %)[[External temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.2SetExternalSensorMode]]|(% style="width:104px" %)(((
297 -[[Built-In>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
247 +|(% style="width:96px" %)**Value**|(% style="width:164px" %)[[External temperature>>path:#DS18b20_value]]|(% style="width:104px" %)(((
248 +[[Built-In>>path:#SHT20_Temperature]]
298 298  
299 -[[Temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
250 +[[Temperature>>path:#SHT20_Temperature]]
300 300  )))|(% style="width:106px" %)(((
301 -BAT Status &
252 +[[BAT Status &>>path:#BAT_Humidity]]
302 302  
303 -[[Built-in>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
254 +[[Built-in>>path:#BAT_Humidity]]
304 304  
305 -[[Humidity>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
306 -)))|(% style="width:108px" %)Status & Ext|(% style="width:116px" %)(((
307 -[[Unix>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.1SetTransmitIntervalTime]]
256 +[[Humidity>>path:#BAT_Humidity]]
257 +)))|(% style="width:108px" %)[[Status & Ext>>path:#Status_EXT]]|(% style="width:116px" %)(((
258 +[[Unix>>path:#Unix_Time_Stamp]]
308 308  
309 -[[Time Stamp>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.1SetTransmitIntervalTime]]
260 +[[Time Stamp>>path:#Unix_Time_Stamp]]
310 310  )))
311 311  
312 -* **Battery status & **[[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)**Built-in Humidity**>>path:#SHT20_Humidity]]
263 +* **Battery status & **[[(% class="wikiinternallink wikiinternallink" %)**Built-in Humidity**>>path:#SHT20_Humidity]]
313 313  
314 -(% border="1" style="background-color:#ffffcc; color:green; width:587px" %)
265 +(% style="width:587px" %)
315 315  |Bit(bit)|(% style="width:280px" %)[15:14]|(% style="width:136px" %)[11:0]
316 316  |Value|(% style="width:280px" %)(((
317 317  BAT Status
... ... @@ -324,7 +324,7 @@
324 324  
325 325  11(b): Good   (BAT >= 2.65v)
326 326  )))|(% style="width:136px" %)(((
327 -[[Built-in Humidity>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
278 +[[Built-in Humidity>>path:#SHT20_Humidity]]
328 328  
329 329  
330 330  )))
... ... @@ -331,10 +331,12 @@
331 331  
332 332  * **Status & Ext Byte**
333 333  
334 -(% border="1" style="background-color:#ffffcc; color:green; width:732px" %)
285 +(% style="width:732px" %)
335 335  |(% style="width:128px" %)**Bits**|(% style="width:102px" %)**7**|(% style="width:145px" %)**6**|(% style="width:117px" %)**5**|(% style="width:147px" %)**4**|(% style="width:90px" %)**[3:0]**
336 336  |(% style="width:128px" %)**Status & Ext**|(% style="width:102px" %)Not Defined|(% style="width:145px" %)Poll Message Flag|(% style="width:117px" %)Sync time OK|(% style="width:147px" %)Unix Time Request|(% style="width:90px" %)(((
337 -Ext:0b(1001)
288 +Ext:
289 +
290 +0b(1001)
338 338  )))
339 339  
340 340  * Poll Message Flag: 1: This message is a poll message reply, 0: means this is a normal uplink.
... ... @@ -341,14 +341,16 @@
341 341  * Sync time OK: 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server.
342 342  * Unix Time Request:1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this)
343 343  
344 -== 2.5 Show data on Datacake ==
297 +== Show data on Datacake ==
345 345  
346 346  Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
347 347  
301 +
348 348  **Step 1**: Be sure that your device is programmed and properly connected to the LoRaWAN network.
349 349  
350 350  **Step 2**: Configure your Application to forward data to Datacake you will need to add integration. Go to TTN V3 Console ~-~-> Applications ~-~-> Integrations ~-~-> Add Integrations.
351 351  
306 +
352 352  Add Datacake:
353 353  
354 354  [[image:image-20220523000825-7.png||height="262" width="583"]]
... ... @@ -368,11 +368,11 @@
368 368  [[image:image-20220523000825-10.png||height="432" width="762"]]
369 369  
370 370  
371 -== 2.6 Datalog Feature ==
326 +== Datalog Feature ==
372 372  
373 373  This feature is always enabled. When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot.
374 374  
375 -=== 2.6.1 Unix TimeStamp ===
330 +=== Unix TimeStamp ===
376 376  
377 377  LHT65N uses Unix TimeStamp format based on
378 378  
... ... @@ -383,12 +383,12 @@
383 383  
384 384  Below is the converter example
385 385  
386 -[[image:image-20220523001219-12.png||height="302" width="730"]]
341 +[[image:image-20220523001219-12.png||height="353" width="853"]]
387 387  
388 388  So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25
389 389  
390 390  
391 -=== 2.6.2 Set Device Time ===
346 +=== Set Device Time ===
392 392  
393 393  There are two ways to set device’s time:
394 394  
... ... @@ -406,15 +406,16 @@
406 406  User needs to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server.
407 407  
408 408  
409 -=== 2.6.3 Poll sensor value ===
364 +=== Poll sensor value ===
410 410  
411 411  User can poll sensor value based on timestamps from the server. Below is the downlink command.
412 412  
413 413  
414 -(% border="1" style="width:454px" %)
369 +(% style="width:454px" %)
415 415  |(% style="width:69px" %)1byte|(% style="width:129px" %)4bytes|(% style="width:134px" %)4bytes|(% style="width:119px" %)1byte
416 416  |(% style="width:69px" %)31|(% style="width:129px" %)Timestamp start|(% style="width:134px" %)Timestamp end|(% style="width:119px" %)Uplink Interval
417 417  
373 +
418 418  Timestamp start and Timestamp end use Unix TimeStamp format as mentioned above. Devices will reply with all data log during this time period, use the uplink interval.
419 419  
420 420  
... ... @@ -425,7 +425,7 @@
425 425  Uplink Internal =5s,means LHT65N will send one packet every 5s. range 5~~255s.
426 426  
427 427  
428 -=== 2.6.4 Datalog Uplink payload ===
384 +=== Datalog Uplink payload ===
429 429  
430 430  The Datalog poll reply uplink will use below payload format.
431 431  
... ... @@ -432,7 +432,6 @@
432 432  
433 433  Retrieval data payload
434 434  
435 -(% border="1" %)
436 436  |**Size(bytes)**|**2**|**2**|**2**|**1**|**4**
437 437  |**Value**|[[External sensor data>>path:#Extension_sensor_value]]|(((
438 438  [[Built-In>>path:#SHT20_Temperature]]
... ... @@ -448,10 +448,10 @@
448 448  
449 449  )))
450 450  
406 +
451 451  Poll message flag & Ext
452 452  
453 453  
454 -(% border="1" %)
455 455  |**Bits**|**7**|**6**|**5**|**4**|**[3:0]**
456 456  |**Status & Ext**|Not Defined|Poll Message Flag|Sync time OK|Unix Time Request|(((
457 457  Ext:
... ... @@ -459,6 +459,7 @@
459 459  0b(1001)
460 460  )))
461 461  
417 +
462 462  Poll Message Flag: 1: This message is a poll message reply.
463 463  
464 464  * Poll Message Flag is set to 1.
... ... @@ -511,7 +511,7 @@
511 511  
512 512  LHT65N will uplink this payload.
513 513  
514 -[[image:image-20220523001219-13.png||height="421" width="727"]]
470 +[[image:image-20220523001219-13.png]]
515 515  
516 516  7FFF089801464160065F977FFF088E014B41600660097FFF0885014E41600660667FFF0875015141600662BE7FFF086B015541600665167FFF08660155416006676E7FFF085F015A41600669C67FFF0857015D4160066C1E
517 517  
... ... @@ -530,7 +530,7 @@
530 530  Unix time is 0x60065F97=1611030423s=21/1/19 04:27:03
531 531  
532 532  
533 -== 2.7 Alarm Mode ==
489 +== Alarm Mode ==
534 534  
535 535  Alarm mode feature is added since firmware v1.5. When device is in Alarm mode, it will check the built-in sensor temperature in a short interval. If the temperature exceeds the pre-configure range, it will send an uplink immediately.
536 536  
... ... @@ -546,7 +546,7 @@
546 546  
547 547  
548 548  
549 -== 2.8 LED Indicator ==
505 +== LED Indicator ==
550 550  
551 551  The LHT65N has a triple color LED which for easy shows different stage.
552 552  
... ... @@ -561,14 +561,17 @@
561 561  
562 562  ----
563 563  
564 -== 2.9 Installation ==
520 +== Installation ==
565 565  
566 -[[image:image-20220516231650-1.png||height="436" width="428"]]
522 +[[image:image-20220516231650-1.png||height="632" width="620"]]
567 567  
568 -= 3. Sensors & Accessories =
569 569  
570 -== 3.1 E3 Temperature Probe ==
571 571  
526 +
527 += Sensors & Accessories =
528 +
529 +== E3 Temperature Probe ==
530 +
572 572  [[image:image-20220515080154-4.png||height="182" width="161"]] [[image:image-20220515080330-5.png||height="201" width="195"]]
573 573  
574 574  
... ... @@ -580,350 +580,36 @@
580 580  * Operating Range: -40 ~~ 125 °C
581 581  * -55°C to 125°C
582 582  * Working voltage 2.35v ~~ 5v
542 +
583 583  
584 -= 4. Configure LHT65N via AT Command or LoRaWAN Downlink =
544 += Battery & How to replace =
585 585  
586 -Use can configure LHT65N via AT Command or LoRaWAN Downlink.
546 +== Battery Type ==
587 587  
588 -* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
589 -* LoRaWAN Downlink instruction for different platforms:
590 -
591 -[[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]]
592 -
593 -There are two kinds of commands to configure LHT65N, they are:
594 -
595 -* **General Commands**.
596 -
597 -These commands are to configure:
598 -
599 -* General system settings like: uplink interval.
600 -* LoRaWAN protocol & radio-related commands.
601 -
602 -They are the same for all Dragino Devices which supports DLWS-005 LoRaWAN Stack(Note~*~*). These commands can be found on the wiki:
603 -
604 -[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]]
605 -
606 -* **Commands special design for LHT65N**
607 -
608 -These commands are only valid for LHT65N, as below:
609 -
610 -== 4.1 Set Transmit Interval Time ==
611 -
612 -Feature: Change LoRaWAN End Node Transmit Interval.
613 -
614 -**AT Command: AT+TDC**
615 -
616 -(% border="1" %)
617 -|**Command Example**|**Function**|**Response**
618 -|AT+TDC?|Show current transmit Interval|(((
619 -30000
620 -
621 -OK
622 -
623 -the interval is 30000ms = 30s
624 -)))
625 -|AT+TDC=60000|Set Transmit Interval|(((
626 -OK
627 -
628 -Set transmit interval to 60000ms = 60 seconds
629 -)))
630 -
631 -**Downlink Command: 0x01**
632 -
633 -Format: Command Code (0x01) followed by 3 bytes time value.
634 -
635 -If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
636 -
637 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
638 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
639 -
640 -== 4.2 Set External Sensor Mode ==
641 -
642 -Feature: Change External Sensor Mode.
643 -
644 -**AT Command: AT+EXT**
645 -
646 -(% border="1" %)
647 -|**Command Example**|**Function**|**Response**
648 -|AT+EXT?|Get current external sensor mode|(((
649 -1
650 -
651 -OK
652 -
653 -External Sensor mode =1
654 -)))
655 -|AT+EXT=1|(% colspan="2" %)Set external sensor mode to 1
656 -|AT+EXT=9|(% colspan="2" %)Set to external DS18B20 with timestamp
657 -
658 -**Downlink Command: 0xA2**
659 -
660 -Total bytes: 2 ~~ 5 bytes
661 -
662 -Example:
663 -
664 -* 0xA201: Set external sensor type to E1
665 -* 0xA209: Same as AT+EXT=9
666 -* 0xA20702003c,Same as AT+SETCNT=60
667 -
668 -== 4.3 Enable/Disable uplink Temperature probe ID ==
669 -
670 -Feature: If PID is enabled, device will send the temperature probe ID on:
671 -
672 -* First Packet after OTAA Join
673 -* Every 24 hours since the first packet.
674 -
675 -PID is default set to disable (0)
676 -
677 -
678 -**AT Command:**
679 -
680 -(% border="1" %)
681 -|**Command Example**|**Function**|**Response**
682 -|AT+PID=1|Enable PID uplink|OK
683 -
684 -**Downlink Command:**
685 -
686 -* 0xA800     à AT+PID=0
687 -* 0xA801     à AT+PID=1
688 -
689 -== 4.4 Set Password ==
690 -
691 -Feature: Set device password, max 9 digits
692 -
693 -**AT Command: AT+PWORD**
694 -
695 -(% border="1" %)
696 -|**Command Example**|**Function**|**Response**
697 -|AT+PWORD=?|Show password|(((
698 -123456
699 -
700 -
701 -OK
702 -)))
703 -|AT+PWORD=999999|Set password|OK
704 -
705 -**Downlink Command:**
706 -
707 -No downlink command for this feature.
708 -
709 -== 4.5 Quit AT Command ==
710 -
711 -Feature: Quit AT Command mode, so user needs to input password again before use AT Commands.
712 -
713 -**AT Command: AT+DISAT**
714 -
715 -(% border="1" %)
716 -|**Command Example**|**Function**|**Response**
717 -|AT+DISAT|Quit AT Commands mode|OK
718 -
719 -**Downlink Command:**
720 -
721 -No downlink command for this feature.
722 -
723 -
724 -== 4.6 Set to sleep mode ==
725 -
726 -Feature: Set device to sleep mode
727 -
728 -**AT Command: AT+SLEEP**
729 -
730 -(% border="1" %)
731 -| | |
732 -|**Command Example**|**Function**|**Response**
733 -|AT+SLEEP|Set to sleep mode|(((
734 -Clear all stored sensor data…
735 -
736 -OK
737 -)))
738 -
739 -**Downlink Command:**
740 -
741 -* There is no downlink command to set to Sleep mode.
742 -
743 -== 4.7 Set system time ==
744 -
745 -Feature: Set system time, unix format. [[See here for format detail.>>path:#TimeStamp]]
746 -
747 -**AT Command:**
748 -
749 -(% border="1" %)
750 -|**Command Example**|**Function**
751 -|AT+TIMESTAMP=1611104352|(((
752 -OK
753 -
754 -Set System time to 2021-01-20 00:59:12
755 -)))
756 -
757 -**Downlink Command:**
758 -
759 -0x306007806000 ~/~/ Set timestamp to 0x(6007806000),Same as AT+TIMESTAMP=1611104352
760 -
761 -== 4.8 Set Time Sync Mode ==
762 -
763 -Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply this command.
764 -
765 -SYNCMOD is set to 1 by default. If user want to set a different time from LoRaWAN server, user need to set this to 0.
766 -
767 -
768 -**AT Command:**
769 -
770 -|**Command Example**|**Function**
771 -|AT+SYNCMOD=1|Enable Sync system time via LoRaWAN MAC Command (DeviceTimeReq)
772 -
773 -**Downlink Command:**
774 -
775 -0x28 01 ~/~/ Same As AT+SYNCMOD=1
776 -
777 -0x28 00 ~/~/ Same As AT+SYNCMOD=0
778 -
779 -== 4.9 Set Time Sync Interval ==
780 -
781 -Feature: Define System time sync interval. SYNCTDC default value: 10 days.
782 -
783 -**AT Command:**
784 -
785 -(% border="1" %)
786 -|**Command Example**|**Function**
787 -|AT+SYNCTDC=0x0A|Set SYNCTDC to 10 (0x0A), so the sync time is 10 days.
788 -
789 -**Downlink Command:**
790 -
791 -0x29 0A ~/~/ Same as AT+SYNCTDC=0x0A
792 -
793 -== 4.10 Print data entries base on page. ==
794 -
795 -Feature: Print the sector data from start page to stop page (max is 416 pages).
796 -
797 -**AT Command: AT+PDTA**
798 -
799 -(% border="1" %)
800 -|**Command Example**|**Response**
801 -|(((
802 -AT+PDTA=1,3
803 -
804 -
805 -
806 -Print page 1 to 3
807 -)))|(((
808 -8019500 19/6/26 16:48 1 2992 sht_temp=28.21 sht_hum=71.5 ds_temp=27.31
809 -
810 -8019510 19/6/26 16:53 1 2994 sht_temp=27.64 sht_hum=69.3 ds_temp=26.93
811 -
812 -8019520 19/6/26 16:58 1 2996 sht_temp=28.39 sht_hum=72.0 ds_temp=27.06
813 -
814 -8019530 19/6/26 17:03 1 2996 sht_temp=27.97 sht_hum=70.4 ds_temp=27.12
815 -
816 -8019540 19/6/26 17:08 1 2996 sht_temp=27.80 sht_hum=72.9 ds_temp=27.06
817 -
818 -8019550 19/6/26 17:13 1 2998 sht_temp=27.30 sht_hum=72.4 ds_temp=26.68
819 -
820 -8019560 19/6/26 17:22 1 2992 sht_temp=26.27 sht_hum=62.3 ds_temp=26.56
821 -
822 -8019570
823 -
824 -8019580
825 -
826 -8019590
827 -
828 -80195A0
829 -
830 -80195B0
831 -
832 -80195C0
833 -
834 -80195D0
835 -
836 -80195E0
837 -
838 -80195F0
839 -
840 -
841 -OK
842 -)))
843 -
844 -**Downlink Command:**
845 -
846 -No downlink commands for feature
847 -
848 -== 4.11 Print last few data entries. ==
849 -
850 -Feature: Print the last few data entries
851 -
852 -**AT Command: AT+PLDTA**
853 -
854 -(% border="1" %)
855 -|**Command Example**|**Response**
856 -|(((
857 -AT+PLDTA=5
858 -
859 -
860 -
861 -Print last 5 entries
862 -)))|(((
863 -Stop Tx and RTP events when read sensor data
864 -
865 -1 19/6/26 13:59 1 3005 sht_temp=27.09 sht_hum=79.5 ds_temp=26.75
866 -
867 -2 19/6/26 14:04 1 3007 sht_temp=26.65 sht_hum=74.8 ds_temp=26.43
868 -
869 -3 19/6/26 14:09 1 3007 sht_temp=26.91 sht_hum=77.9 ds_temp=26.56
870 -
871 -4 19/6/26 14:15 1 3007 sht_temp=26.93 sht_hum=76.7 ds_temp=26.75
872 -
873 -5 19/6/26 14:20 1 3007 sht_temp=26.78 sht_hum=76.6 ds_temp=26.43
874 -
875 -Start Tx and RTP events
876 -
877 -OK
878 -)))
879 -
880 -**Downlink Command:**
881 -
882 -No downlink commands for feature
883 -
884 -== 4.12 Clear Flash Record ==
885 -
886 -Feature: Clear flash storage for data log feature.
887 -
888 -**AT Command: AT+CLRDTA**
889 -
890 -(% border="1" %)
891 -|**Command Example**|**Function**|**Response**
892 -|AT+CLRDTA|Clear date record|(((
893 -Clear all stored sensor data…
894 -
895 -OK
896 -)))
897 -
898 -**Downlink Command: 0xA3**
899 -
900 -* Example: 0xA301 ~/~/Same as AT+CLRDTA
901 -
902 -= 5. Battery & How to replace =
903 -
904 -== 5.1 Battery Type ==
905 -
906 906  LHT65N is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters.
907 907  
908 908  The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
909 909  [[image:image-20220515075034-1.png||height="208" width="644"]]
910 910  
553 +
911 911  The minimum Working Voltage for the LHT65N is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery.
912 912  
913 913  
914 -== 5.2 Replace Battery ==
557 +== Replace Battery ==
915 915  
916 916  LHT65N has two screws on the back, Unscrew them, and changing the battery inside is ok. The battery is a general CR17450 battery. Any brand should be ok.
917 917  
918 918  [[image:image-20220515075440-2.png||height="338" width="272"]][[image:image-20220515075625-3.png||height="193" width="257"]]
919 919  
920 -== 5.3 Battery Life Analyze ==
921 921  
564 +== Battery Life Analyze ==
565 +
922 922  Dragino battery-powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimated battery life:
923 923  https:~/~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf
924 924  
925 -= 6. Order Info =
926 926  
570 += Order Info =
571 +
927 927  Part Number: (% class="mark" %)**LHT65N-XX**
928 928  
929 929  **XX**: The default frequency band
... ... @@ -941,7 +941,7 @@
941 941  
942 942  * **E3**: External Temperature Probe
943 943  
944 -= 7. Packing Info =
589 += Packing Info =
945 945  
946 946  **Package Includes**:
947 947  
... ... @@ -956,10 +956,10 @@
956 956  * Package Size / pcs : 14.5 x 8 x 5 cm
957 957  * Weight / pcs : 170g
958 958  
959 -= 8. FCC Warning =
604 += FCC Warning =
960 960  
961 961  This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions:
962 962  
963 -(1) This device may not cause harmful interference
608 +(1) This device may not cause harmful interference, and
964 964  
965 -(2) this device must accept any interference received, including interference that may cause undesired operation.
610 +(2) this device must accept any interference received, including interference that may cause undesired operation
image-20220523111447-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -910.1 KB
Content
image-20220523112300-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -27.5 KB
Content
image-20220523115324-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -910.1 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0