Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -132,11 +132,11 @@ 132 132 133 133 [[image:image-20220515123819-1.png||height="379" width="317"]] 134 134 135 -(% border="1" %) 136 -|**Behavior on ACT**|**Function**|**Action** 137 -|**Pressing ACT between 1s < time < 3s**|Test uplink status|If LHT65N is already Joined to the LoRaWAN network, LHT65N will send an uplink packet, if LHT65N has an external sensor connected, blue led will blink once. If LHT65N has no external sensor, red led will blink once. 138 -|**Pressing ACT for more than 3s**|Active Device|green led will fast blink 5 times, LHT65N will enter working mode and start to JOIN LoRaWAN network. green led will solid turn on for 5 seconds after join in network. 139 -|**Fast press ACT 5 times**|Deactivate Device|red led will solid on for 5 seconds. This means LHT65N is in Deep Sleep Mode. 135 +(% border="1" style="background-color:#ffffcc; color:green; width:739px" %) 136 +|**Behavior on ACT**|**Function**|(% style="width:424px" %)**Action** 137 +|**Pressing ACT between 1s < time < 3s**|Test uplink status|(% style="width:424px" %)If LHT65N is already Joined to the LoRaWAN network, LHT65N will send an uplink packet, if LHT65N has an external sensor connected, blue led will blink once. If LHT65N has no external sensor, red led will blink once. 138 +|**Pressing ACT for more than 3s**|Active Device|(% style="width:424px" %)green led will fast blink 5 times, LHT65N will enter working mode and start to JOIN LoRaWAN network. green led will solid turn on for 5 seconds after join in network. 139 +|**Fast press ACT 5 times**|Deactivate Device|(% style="width:424px" %)red led will solid on for 5 seconds. This means LHT65N is in Deep Sleep Mode. 140 140 141 141 == 2.3 Example to join LoRaWAN network == 142 142 ... ... @@ -183,7 +183,7 @@ 183 183 184 184 Use ACT button to activate LHT65N and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel. 185 185 186 -[[image:image-20220522233300-8.png]] 186 +[[image:image-20220522233300-8.png||height="219" width="722"]] 187 187 188 188 189 189 == 2.4 Uplink Payload == ... ... @@ -193,18 +193,14 @@ 193 193 After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once. 194 194 195 195 196 -(% border="1" style="width:572px" %) 197 -|(% style="width:106px" %)**Size(bytes)**|(% style="width:71px" %)**2**|(% style="width:128px" %)**2**|(% style="width:103px" %)**2**|(% style="width:72px" %)**1**|(% style="width:89px" %)**4** 198 -|(% style="width:106px" %)**Value**|(% style="width:71px" %)[[BAT>>path:#Battery]]|(% style="width:128px" %)((( 199 -[[Built-In>>path:#SHT20_Temperature]] 196 +(% border="1" style="width:605px" %) 197 +|(% style="width:106px" %)**Size(bytes)**|(% style="width:71px" %)**2**|(% style="width:183px" %)**2**|(% style="width:155.172px" %)**2**|(% style="width:49px" %)**1**|(% style="width:92px" %)**4** 198 +|(% style="width:106px" %)**Value**|(% style="width:71px" %)[[BAT>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.2BAT-BatteryInfo]]|(% style="width:183px" %)((( 199 +[[Built In Temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]] 200 +)))|(% style="width:155.172px" %)((( 201 +[[Built-in Humidity>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]] 202 +)))|(% style="width:49px" %)[[Ext>>path:#Extension_Sensor]] #|(% style="width:92px" %)[[Ext value>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.6Extvalue]] 200 200 201 -[[Temperature>>path:#SHT20_Temperature]] 202 -)))|(% style="width:103px" %)((( 203 -[[Built-in>>path:#SHT20_Humidity]] 204 - 205 -[[Humidity>>path:#SHT20_Humidity]] 206 -)))|(% style="width:72px" %)[[Ext>>path:#Extension_Sensor]] #|(% style="width:89px" %)[[Ext value>>path:#Extension_sensor_value]] 207 - 208 208 * The First 6 bytes: has fix meanings for every LHT65N. 209 209 * The 7th byte (EXT #): defines the external sensor model. 210 210 * The 8^^th^^ ~~ 11^^th^^ byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won’t be these four bytes.) ... ... @@ -217,16 +217,15 @@ 217 217 218 218 [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0 >>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]] 219 219 220 -[[image:image-20220522234118-10.png]] 216 +[[image:image-20220522234118-10.png||height="353" width="729"]] 221 221 222 - 223 223 === 2.4.2 BAT-Battery Info === 224 224 225 225 These two bytes of BAT include the battery state and the actually voltage 226 226 227 -(% style="width: 646px" %)228 -|Bit(bit)|(% style="width:2 72px" %)[15:14]|(% style="width:214px" %)[13:0]229 -|Value|(% style="width:2 72px" %)(((222 +(% border="1" style="width:508px" %) 223 +|(% style="width:75px" %)Bit(bit)|(% style="width:268px" %)[15:14]|(% style="width:162px" %)[13:0] 224 +|(% style="width:75px" %)Value|(% style="width:268px" %)((( 230 230 BAT Status 231 231 232 232 00(b): Ultra Low ( BAT <= 2.50v) ... ... @@ -236,7 +236,7 @@ 236 236 10(b): OK (2.55v <= BAT <=2.65v) 237 237 238 238 11(b): Good (BAT >= 2.65v) 239 -)))|(% style="width: 214px" %)Actually BAT voltage234 +)))|(% style="width:162px" %)Actually BAT voltage 240 240 241 241 [[image:image-20220522235639-1.png]] 242 242