Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,47 +1,33 @@ 1 -(% style="text-align:center" %) 2 -[[image:image-20220523115324-1.jpeg||height="500" width="500"]] 3 - 4 - 5 -**LHT65N LoRaWAN Temperature & Humidity Sensor Manual** 6 - 7 - 8 - 9 -**Table of Contents:** 10 - 1 +{{box cssClass="floatinginfobox" title="**Contents**"}} 11 11 {{toc/}} 3 +{{/box}} 12 12 5 +(% class="wikigeneratedid" %) 6 += = 13 13 14 - 8 +(% class="wikigeneratedid" %) 15 15 = 1.Introduction = 16 16 17 -== 1.1 What is LHT65N Temperature & Humidity Sensor==11 +== 1.1 Overview == 18 18 19 -((( 20 -The Dragino LHT65N Temperature & Humidity sensor is a Long Range LoRaWAN Sensor. It includes a (% style="color:#4f81bd" %)**built-in Temperature & Humidity sensor**(%%) and has an external sensor connector to connect to an external (% style="color:#4f81bd" %)**Temperature Sensor**(%%)**.** 21 -))) 13 +[[image:LHT65N_10.png||alt="LHT65_Image" height="265" width="265"]] 22 22 23 -((( 15 + 16 +The Dragino LHT65N Temperature & Humidity sensor is a Long Range LoRaWAN Sensor. It includes a(% class="mark" %) **built-in Temperature & Humidity sensor**(%%) and has an external sensor connector to connect to an external (% class="mark" %)**Temperature Sensor**(%%)**.** 17 + 24 24 The LHT65N allows users to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, building automation, and so on. 25 -))) 26 26 27 -((( 28 28 LHT65N has a built-in 2400mAh non-chargeable battery which can be used for up to 10 years*. 29 -))) 30 30 31 -((( 32 32 LHT65N is full compatible with LoRaWAN v1.0.3 Class A protocol, it can work with a standard LoRaWAN gateway. 33 -))) 34 34 35 -((( 36 -LHT65N supports (% style="color:#4f81bd" %)**Datalog Feature**(%%). It will record the data when there is no network coverage and users can retrieve the sensor value later to ensure no miss for every sensor reading. 37 -))) 24 +LHT65N supports (% class="mark" %)Datalog Feature(%%). It will record the data when there is no network coverage and users can retrieve the sensor value later to ensure no miss for every sensor reading. 38 38 39 -((( 40 40 *The actual battery life depends on how often to send data, please see the battery analyzer chapter. 41 -))) 42 42 43 -== 1.2 Features == 44 44 29 +== Features: == 30 + 45 45 * Wall mountable 46 46 * LoRaWAN v1.0.3 Class A protocol 47 47 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915 ... ... @@ -54,62 +54,32 @@ 54 54 * Tri-color LED to indicate working status 55 55 * Datalog feature 56 56 57 -== 1.3Specification ==43 +== Specification: == 58 58 59 -((( 60 60 **Built-in Temperature Sensor:** 61 -))) 62 62 63 -* ((( 64 -Resolution: 0.01 °C 65 -))) 66 -* ((( 67 -Accuracy Tolerance : Typ ±0.3 °C 68 -))) 69 -* ((( 70 -Long Term Drift: < 0.02 °C/yr 71 -))) 72 -* ((( 73 -Operating Range: -40 ~~ 85 °C 74 -))) 47 +* Resolution: 0.01 °C 48 +* Accuracy Tolerance : Typ ±0.3 °C 49 +* Long Term Drift: < 0.02 °C/yr 50 +* Operating Range: -40 ~~ 85 °C 75 75 76 -((( 77 77 **Built-in Humidity Sensor:** 78 -))) 79 79 80 -* ((( 81 -Resolution: 0.04 %RH 82 -))) 83 -* ((( 84 -Accuracy Tolerance : Typ ±3 %RH 85 -))) 86 -* ((( 87 -Long Term Drift: < 0.02 °C/yr 88 -))) 89 -* ((( 90 -Operating Range: 0 ~~ 96 %RH 91 -))) 54 +* Resolution: 0.04 %RH 55 +* Accuracy Tolerance : Typ ±3 %RH 56 +* Long Term Drift: < 0.02 °C/yr 57 +* Operating Range: 0 ~~ 96 %RH 92 92 93 -((( 94 94 **External Temperature Sensor:** 95 -))) 96 96 97 -* ((( 98 -Resolution: 0.0625 °C 99 -))) 100 -* ((( 101 -±0.5°C accuracy from -10°C to +85°C 102 -))) 103 -* ((( 104 -±2°C accuracy from -55°C to +125°C 105 -))) 106 -* ((( 107 -Operating Range: -55 °C ~~ 125 °C 108 -))) 61 +* Resolution: 0.0625 °C 62 +* ±0.5°C accuracy from -10°C to +85°C 63 +* ±2°C accuracy from -55°C to +125°C 64 +* Operating Range: -55 °C ~~ 125 °C 109 109 110 -= 2.Connect LHT65N to IoT Server =66 += Connect LHT65N to IoT Server = 111 111 112 -== 2.1How does LHT65N work? ==68 +== How does LHT65N work? == 113 113 114 114 LHT65N is configured as LoRaWAN OTAA Class A mode by default. Each LHT65N is shipped with a worldwide unique set of OTAA keys. To use LHT65N in a LoRaWAN network, first, we need to put the OTAA keys in LoRaWAN Network Server and then activate LHT65N. 115 115 ... ... @@ -116,7 +116,7 @@ 116 116 If LHT65N is under the coverage of this LoRaWAN network. LHT65N can join the LoRaWAN network automatically. After successfully joining, LHT65N will start to measure environment temperature and humidity, and start to transmit sensor data to the LoRaWAN server. The default period for each uplink is 20 minutes. 117 117 118 118 119 -== 2.2How to Activate LHT65N? ==75 +== How to Activate LHT65N? == 120 120 121 121 The LHT65N has two working modes: 122 122 ... ... @@ -127,13 +127,12 @@ 127 127 128 128 [[image:image-20220515123819-1.png||height="379" width="317"]] 129 129 130 -(% border="1" %) 131 131 |**Behavior on ACT**|**Function**|**Action** 132 132 |**Pressing ACT between 1s < time < 3s**|Test uplink status|If LHT65N is already Joined to the LoRaWAN network, LHT65N will send an uplink packet, if LHT65N has an external sensor connected, blue led will blink once. If LHT65N has no external sensor, red led will blink once. 133 133 |**Pressing ACT for more than 3s**|Active Device|green led will fast blink 5 times, LHT65N will enter working mode and start to JOIN LoRaWAN network. green led will solid turn on for 5 seconds after join in network. 134 134 |**Fast press ACT 5 times**|Deactivate Device|red led will solid on for 5 seconds. This means LHT65N is in Deep Sleep Mode. 135 135 136 -== 2.3Example to join LoRaWAN network ==91 +== Example to join LoRaWAN network == 137 137 138 138 (% class="wikigeneratedid" %) 139 139 This section shows an example of how to join the TTN V3 LoRaWAN IoT server. Use with other LoRaWAN IoT servers is of a similar procedure. ... ... @@ -144,7 +144,7 @@ 144 144 Assume the LPS8N is already set to connect to [[TTN V3 network>>url:https://eu1.cloud.thethings.network]], So it provides network coverage for LHT65N. Next we need to add the LHT65N device in TTN V3: 145 145 146 146 147 -=== 2.3.1Step 1: Create Device n TTN ===102 +=== **Step 1**: Create Device n TTN === 148 148 149 149 Create a device in TTN V3 with the OTAA keys from LHT65N. 150 150 ... ... @@ -174,7 +174,7 @@ 174 174 [[image:image-20220522233118-7.png]] 175 175 176 176 177 -=== 2.3.2Step 2: Activate LHT65N by pressing the ACT button for more than 5 seconds. ===132 +=== Step 2: Activate LHT65N by pressing the ACT button for more than 5 seconds. === 178 178 179 179 Use ACT button to activate LHT65N and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel. 180 180 ... ... @@ -181,7 +181,7 @@ 181 181 [[image:image-20220522233300-8.png]] 182 182 183 183 184 -== 2.4Uplink Payload ==139 +== Uplink Payload: == 185 185 186 186 The uplink payload includes totally 11 bytes. Uplink packets use FPORT=2 and(% class="mark" %) every 20 minutes(%%) send one uplink by default. 187 187 ... ... @@ -188,7 +188,7 @@ 188 188 After each uplink, the (% class="mark" %)BLUE LED(%%) will blink once. 189 189 190 190 191 -(% border="1"style="width:572px" %)146 +(% style="width:572px" %) 192 192 |(% style="width:106px" %)**Size(bytes)**|(% style="width:71px" %)**2**|(% style="width:128px" %)**2**|(% style="width:103px" %)**2**|(% style="width:72px" %)**1**|(% style="width:89px" %)**4** 193 193 |(% style="width:106px" %)**Value**|(% style="width:71px" %)[[BAT>>path:#Battery]]|(% style="width:128px" %)((( 194 194 [[Built-In>>path:#SHT20_Temperature]] ... ... @@ -204,7 +204,7 @@ 204 204 * The 7th byte (EXT #): defines the external sensor model. 205 205 * The 8^^th^^ ~~ 11^^th^^ byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won’t be these four bytes.) 206 206 207 -=== 2.4.1Decoder in TTN V3 ===162 +=== Decoder in TTN V3 === 208 208 209 209 When the uplink payload arrives TTNv3, it shows HEX format and not friendly to read. We can add LHT65N decoder in TTNv3 for friendly reading. 210 210 ... ... @@ -215,7 +215,7 @@ 215 215 [[image:image-20220522234118-10.png]] 216 216 217 217 218 -=== 2.4.2BAT-Battery Info ===173 +=== BAT-Battery Info === 219 219 220 220 These two bytes of BAT include the battery state and the actually voltage 221 221 ... ... @@ -240,7 +240,7 @@ 240 240 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 241 241 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 242 242 243 -=== 2.4.3Built-in Temperature ===198 +=== Built-in Temperature === 244 244 245 245 [[image:image-20220522235639-2.png]] 246 246 ... ... @@ -250,13 +250,13 @@ 250 250 251 251 * Temperature: (0xF5C6-65536)/100=-26.18℃ 252 252 253 -=== 2.4.4Built-in Humidity ===208 +=== Built-in Humidity === 254 254 255 255 [[image:image-20220522235639-4.png]] 256 256 257 257 * Humidity: 0x025C/10=60.4% 258 258 259 -=== 2.4.5Ext # ===214 +=== Ext # === 260 260 261 261 Bytes for External Sensor: 262 262 ... ... @@ -265,16 +265,19 @@ 265 265 |(% style="width:139px" %)0x01|(% style="width:484px" %)Sensor E3, Temperature Sensor 266 266 |(% style="width:139px" %)0x09|(% style="width:484px" %)Sensor E3, Temperature Sensor, Datalog Mod 267 267 268 -=== 2.4.6Ext value ===223 +=== Ext value === 269 269 270 -==== 2.4.6.1Ext~=1, E3 Temperature Sensor ====225 +==== Ext~=1, E3 Temperature Sensor ==== 271 271 272 272 [[image:image-20220522235639-5.png]] 273 273 229 + 274 274 * DS18B20 temp=0x0ADD/100=27.81℃ 275 275 276 276 The last 2 bytes of data are meaningless 277 277 234 + 235 + 278 278 [[image:image-20220522235639-6.png]] 279 279 280 280 * External temperature= (0xF54F-65536)/100=-27.37℃ ... ... @@ -281,15 +281,16 @@ 281 281 282 282 The last 2 bytes of data are meaningless 283 283 242 + 284 284 If the external sensor is 0x01, and there is no external temperature connected. The temperature will be set to 7FFF which is 327.67℃ 285 285 286 286 287 -==== 2.4.6.2Ext~=9, E3 sensor with Unix Timestamp ====246 +==== Ext~=9, E3 sensor with Unix Timestamp ==== 288 288 289 289 Timestamp mode is designed for LHT65N with E3 probe, it will send the uplink payload with Unix timestamp. With the limitation of 11 bytes (max distance of AU915/US915/AS923 band), the time stamp mode will be lack of BAT voltage field, instead, it shows the battery status. The payload is as below: 290 290 291 291 292 -(% border="1"style="width:697px" %)251 +(% style="width:697px" %) 293 293 |(% style="width:96px" %)**Size(bytes)**|(% style="width:164px" %)**2**|(% style="width:104px" %)**2**|(% style="width:106px" %)**2**|(% style="width:108px" %)**1**|(% style="width:116px" %)**4** 294 294 |(% style="width:96px" %)**Value**|(% style="width:164px" %)[[External temperature>>path:#DS18b20_value]]|(% style="width:104px" %)((( 295 295 [[Built-In>>path:#SHT20_Temperature]] ... ... @@ -307,9 +307,9 @@ 307 307 [[Time Stamp>>path:#Unix_Time_Stamp]] 308 308 ))) 309 309 310 -* **Battery status & **[[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)**Built-in Humidity**>>path:#SHT20_Humidity]]269 +* **Battery status & **[[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)**Built-in Humidity**>>path:#SHT20_Humidity]] 311 311 312 -(% border="1"style="width:587px" %)271 +(% style="width:587px" %) 313 313 |Bit(bit)|(% style="width:280px" %)[15:14]|(% style="width:136px" %)[11:0] 314 314 |Value|(% style="width:280px" %)((( 315 315 BAT Status ... ... @@ -329,7 +329,7 @@ 329 329 330 330 * **Status & Ext Byte** 331 331 332 -(% border="1"style="width:732px" %)291 +(% style="width:732px" %) 333 333 |(% style="width:128px" %)**Bits**|(% style="width:102px" %)**7**|(% style="width:145px" %)**6**|(% style="width:117px" %)**5**|(% style="width:147px" %)**4**|(% style="width:90px" %)**[3:0]** 334 334 |(% style="width:128px" %)**Status & Ext**|(% style="width:102px" %)Not Defined|(% style="width:145px" %)Poll Message Flag|(% style="width:117px" %)Sync time OK|(% style="width:147px" %)Unix Time Request|(% style="width:90px" %)((( 335 335 Ext: ... ... @@ -341,10 +341,11 @@ 341 341 * Sync time OK: 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 342 342 * Unix Time Request:1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 343 343 344 -== 2.5Show data on Datacake ==303 +== Show data on Datacake == 345 345 346 346 Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: 347 347 307 + 348 348 **Step 1**: Be sure that your device is programmed and properly connected to the LoRaWAN network. 349 349 350 350 **Step 2**: Configure your Application to forward data to Datacake you will need to add integration. Go to TTN V3 Console ~-~-> Applications ~-~-> Integrations ~-~-> Add Integrations. ... ... @@ -369,11 +369,11 @@ 369 369 [[image:image-20220523000825-10.png||height="432" width="762"]] 370 370 371 371 372 -== 2.6Datalog Feature ==332 +== Datalog Feature == 373 373 374 374 This feature is always enabled. When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot. 375 375 376 -=== 2.6.1Unix TimeStamp ===336 +=== Unix TimeStamp === 377 377 378 378 LHT65N uses Unix TimeStamp format based on 379 379 ... ... @@ -384,12 +384,12 @@ 384 384 385 385 Below is the converter example 386 386 387 -[[image:image-20220523001219-12.png||height="3 02" width="730"]]347 +[[image:image-20220523001219-12.png||height="353" width="853"]] 388 388 389 389 So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 390 390 391 391 392 -=== 2.6.2Set Device Time ===352 +=== Set Device Time === 393 393 394 394 There are two ways to set device’s time: 395 395 ... ... @@ -407,12 +407,12 @@ 407 407 User needs to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server. 408 408 409 409 410 -=== 2.6.3Poll sensor value ===370 +=== Poll sensor value === 411 411 412 412 User can poll sensor value based on timestamps from the server. Below is the downlink command. 413 413 414 414 415 -(% border="1"style="width:454px" %)375 +(% style="width:454px" %) 416 416 |(% style="width:69px" %)1byte|(% style="width:129px" %)4bytes|(% style="width:134px" %)4bytes|(% style="width:119px" %)1byte 417 417 |(% style="width:69px" %)31|(% style="width:129px" %)Timestamp start|(% style="width:134px" %)Timestamp end|(% style="width:119px" %)Uplink Interval 418 418 ... ... @@ -426,7 +426,7 @@ 426 426 Uplink Internal =5s,means LHT65N will send one packet every 5s. range 5~~255s. 427 427 428 428 429 -=== 2.6.4Datalog Uplink payload ===389 +=== Datalog Uplink payload === 430 430 431 431 The Datalog poll reply uplink will use below payload format. 432 432 ... ... @@ -433,7 +433,6 @@ 433 433 434 434 Retrieval data payload 435 435 436 -(% border="1" %) 437 437 |**Size(bytes)**|**2**|**2**|**2**|**1**|**4** 438 438 |**Value**|[[External sensor data>>path:#Extension_sensor_value]]|((( 439 439 [[Built-In>>path:#SHT20_Temperature]] ... ... @@ -452,7 +452,6 @@ 452 452 Poll message flag & Ext 453 453 454 454 455 -(% border="1" %) 456 456 |**Bits**|**7**|**6**|**5**|**4**|**[3:0]** 457 457 |**Status & Ext**|Not Defined|Poll Message Flag|Sync time OK|Unix Time Request|((( 458 458 Ext: ... ... @@ -512,7 +512,7 @@ 512 512 513 513 LHT65N will uplink this payload. 514 514 515 -[[image:image-20220523001219-13.png ||height="421" width="727"]]473 +[[image:image-20220523001219-13.png]] 516 516 517 517 7FFF089801464160065F977FFF088E014B41600660097FFF0885014E41600660667FFF0875015141600662BE7FFF086B015541600665167FFF08660155416006676E7FFF085F015A41600669C67FFF0857015D4160066C1E 518 518 ... ... @@ -531,7 +531,7 @@ 531 531 Unix time is 0x60065F97=1611030423s=21/1/19 04:27:03 532 532 533 533 534 -== 2.7Alarm Mode ==492 +== Alarm Mode == 535 535 536 536 Alarm mode feature is added since firmware v1.5. When device is in Alarm mode, it will check the built-in sensor temperature in a short interval. If the temperature exceeds the pre-configure range, it will send an uplink immediately. 537 537 ... ... @@ -547,7 +547,7 @@ 547 547 548 548 549 549 550 -== 2.8LED Indicator ==508 +== LED Indicator == 551 551 552 552 The LHT65N has a triple color LED which for easy shows different stage. 553 553 ... ... @@ -562,14 +562,17 @@ 562 562 563 563 ---- 564 564 565 -== 2.9Installation ==523 +== Installation == 566 566 567 567 [[image:image-20220516231650-1.png||height="436" width="428"]] 568 568 569 -= 3. Sensors & Accessories = 570 570 571 -== 3.1 E3 Temperature Probe == 572 572 529 + 530 += Sensors & Accessories = 531 + 532 +== E3 Temperature Probe == 533 + 573 573 [[image:image-20220515080154-4.png||height="182" width="161"]] [[image:image-20220515080330-5.png||height="201" width="195"]] 574 574 575 575 ... ... @@ -582,7 +582,7 @@ 582 582 * -55°C to 125°C 583 583 * Working voltage 2.35v ~~ 5v 584 584 585 -= 4.Configure LHT65N via AT Command or LoRaWAN Downlink =546 += Configure LHT65N via AT Command or LoRaWAN Downlink = 586 586 587 587 Use can configure LHT65N via AT Command or LoRaWAN Downlink. 588 588 ... ... @@ -591,6 +591,7 @@ 591 591 592 592 [[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]] 593 593 555 + 594 594 There are two kinds of commands to configure LHT65N, they are: 595 595 596 596 * **General Commands**. ... ... @@ -604,17 +604,19 @@ 604 604 605 605 [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]] 606 606 569 + 570 + 607 607 * **Commands special design for LHT65N** 608 608 609 609 These commands are only valid for LHT65N, as below: 610 610 611 -== 4.1 Set Transmit Interval Time == 612 612 576 +== Set Transmit Interval Time == 577 + 613 613 Feature: Change LoRaWAN End Node Transmit Interval. 614 614 615 615 **AT Command: AT+TDC** 616 616 617 -(% border="1" %) 618 618 |**Command Example**|**Function**|**Response** 619 619 |AT+TDC?|Show current transmit Interval|((( 620 620 30000 ... ... @@ -638,13 +638,12 @@ 638 638 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 639 639 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 640 640 641 -== 4.2Set External Sensor Mode ==605 +== Set External Sensor Mode == 642 642 643 643 Feature: Change External Sensor Mode. 644 644 645 645 **AT Command: AT+EXT** 646 646 647 -(% border="1" %) 648 648 |**Command Example**|**Function**|**Response** 649 649 |AT+EXT?|Get current external sensor mode|((( 650 650 1 ... ... @@ -666,7 +666,7 @@ 666 666 * 0xA209: Same as AT+EXT=9 667 667 * 0xA20702003c,Same as AT+SETCNT=60 668 668 669 -== 4.3Enable/Disable uplink Temperature probe ID ==632 +== Enable/Disable uplink Temperature probe ID == 670 670 671 671 Feature: If PID is enabled, device will send the temperature probe ID on: 672 672 ... ... @@ -678,7 +678,6 @@ 678 678 679 679 **AT Command:** 680 680 681 -(% border="1" %) 682 682 |**Command Example**|**Function**|**Response** 683 683 |AT+PID=1|Enable PID uplink|OK 684 684 ... ... @@ -687,13 +687,13 @@ 687 687 * 0xA800 à AT+PID=0 688 688 * 0xA801 à AT+PID=1 689 689 690 -== 4.4 Set Password == 691 691 653 +== Set Password == 654 + 692 692 Feature: Set device password, max 9 digits 693 693 694 694 **AT Command: AT+PWORD** 695 695 696 -(% border="1" %) 697 697 |**Command Example**|**Function**|**Response** 698 698 |AT+PWORD=?|Show password|((( 699 699 123456 ... ... @@ -707,13 +707,13 @@ 707 707 708 708 No downlink command for this feature. 709 709 710 -== 4.5 Quit AT Command == 711 711 673 +== Quit AT Command == 674 + 712 712 Feature: Quit AT Command mode, so user needs to input password again before use AT Commands. 713 713 714 714 **AT Command: AT+DISAT** 715 715 716 -(% border="1" %) 717 717 |**Command Example**|**Function**|**Response** 718 718 |AT+DISAT|Quit AT Commands mode|OK 719 719 ... ... @@ -722,13 +722,12 @@ 722 722 No downlink command for this feature. 723 723 724 724 725 -== 4.6Set to sleep mode ==687 +== Set to sleep mode == 726 726 727 727 Feature: Set device to sleep mode 728 728 729 729 **AT Command: AT+SLEEP** 730 730 731 -(% border="1" %) 732 732 | | | 733 733 |**Command Example**|**Function**|**Response** 734 734 |AT+SLEEP|Set to sleep mode|((( ... ... @@ -741,13 +741,13 @@ 741 741 742 742 * There is no downlink command to set to Sleep mode. 743 743 744 -== 4.7 Set system time == 745 745 706 +== Set system time == 707 + 746 746 Feature: Set system time, unix format. [[See here for format detail.>>path:#TimeStamp]] 747 747 748 748 **AT Command:** 749 749 750 -(% border="1" %) 751 751 |**Command Example**|**Function** 752 752 |AT+TIMESTAMP=1611104352|((( 753 753 OK ... ... @@ -759,10 +759,12 @@ 759 759 760 760 0x306007806000 ~/~/ Set timestamp to 0x(6007806000),Same as AT+TIMESTAMP=1611104352 761 761 762 -== 4.8 Set Time Sync Mode == 763 763 724 +== Set Time Sync Mode == 725 + 764 764 Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply this command. 765 765 728 + 766 766 SYNCMOD is set to 1 by default. If user want to set a different time from LoRaWAN server, user need to set this to 0. 767 767 768 768 ... ... @@ -777,13 +777,13 @@ 777 777 778 778 0x28 00 ~/~/ Same As AT+SYNCMOD=0 779 779 780 -== 4.9 Set Time Sync Interval == 781 781 744 +== Set Time Sync Interval == 745 + 782 782 Feature: Define System time sync interval. SYNCTDC default value: 10 days. 783 783 784 784 **AT Command:** 785 785 786 -(% border="1" %) 787 787 |**Command Example**|**Function** 788 788 |AT+SYNCTDC=0x0A|Set SYNCTDC to 10 (0x0A), so the sync time is 10 days. 789 789 ... ... @@ -791,13 +791,13 @@ 791 791 792 792 0x29 0A ~/~/ Same as AT+SYNCTDC=0x0A 793 793 794 -== 4.10 Print data entries base on page. == 795 795 758 +== Print data entries base on page. == 759 + 796 796 Feature: Print the sector data from start page to stop page (max is 416 pages). 797 797 798 798 **AT Command: AT+PDTA** 799 799 800 -(% border="1" %) 801 801 |**Command Example**|**Response** 802 802 |((( 803 803 AT+PDTA=1,3 ... ... @@ -846,13 +846,14 @@ 846 846 847 847 No downlink commands for feature 848 848 849 -== 4.11 Print last few data entries. == 850 850 813 + 814 +== Print last few data entries. == 815 + 851 851 Feature: Print the last few data entries 852 852 853 853 **AT Command: AT+PLDTA** 854 854 855 -(% border="1" %) 856 856 |**Command Example**|**Response** 857 857 |((( 858 858 AT+PLDTA=5 ... ... @@ -882,13 +882,14 @@ 882 882 883 883 No downlink commands for feature 884 884 885 -== 4.12 Clear Flash Record == 886 886 850 + 851 +== Clear Flash Record == 852 + 887 887 Feature: Clear flash storage for data log feature. 888 888 889 889 **AT Command: AT+CLRDTA** 890 890 891 -(% border="1" %) 892 892 |**Command Example**|**Function**|**Response** 893 893 |AT+CLRDTA|Clear date record|((( 894 894 Clear all stored sensor data… ... ... @@ -900,31 +900,36 @@ 900 900 901 901 * Example: 0xA301 ~/~/Same as AT+CLRDTA 902 902 903 -= 5. Battery & How to replace = 904 904 905 -== 5.1 Battery Type == 906 906 870 += Battery & How to replace = 871 + 872 +== Battery Type == 873 + 907 907 LHT65N is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters. 908 908 909 909 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 910 910 [[image:image-20220515075034-1.png||height="208" width="644"]] 911 911 879 + 912 912 The minimum Working Voltage for the LHT65N is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery. 913 913 914 914 915 -== 5.2Replace Battery ==883 +== Replace Battery == 916 916 917 917 LHT65N has two screws on the back, Unscrew them, and changing the battery inside is ok. The battery is a general CR17450 battery. Any brand should be ok. 918 918 919 919 [[image:image-20220515075440-2.png||height="338" width="272"]][[image:image-20220515075625-3.png||height="193" width="257"]] 920 920 921 -== 5.3 Battery Life Analyze == 922 922 890 +== Battery Life Analyze == 891 + 923 923 Dragino battery-powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimated battery life: 924 924 https:~/~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf 925 925 926 -= 6. Order Info = 927 927 896 += Order Info = 897 + 928 928 Part Number: (% class="mark" %)**LHT65N-XX** 929 929 930 930 **XX**: The default frequency band ... ... @@ -942,7 +942,7 @@ 942 942 943 943 * **E3**: External Temperature Probe 944 944 945 -= 7.Packing Info =915 += Packing Info = 946 946 947 947 **Package Includes**: 948 948 ... ... @@ -957,10 +957,10 @@ 957 957 * Package Size / pcs : 14.5 x 8 x 5 cm 958 958 * Weight / pcs : 170g 959 959 960 -= 8.FCC Warning =930 += FCC Warning = 961 961 962 962 This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions: 963 963 964 -(1) This device may not cause harmful interference ;934 +(1) This device may not cause harmful interference, and 965 965 966 -(2) this device must accept any interference received, including interference that may cause undesired operation .936 +(2) this device must accept any interference received, including interference that may cause undesired operation
- image-20220523111447-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -910.1 KB - Content
- image-20220523112300-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -27.5 KB - Content
- image-20220523115324-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -910.1 KB - Content