Last modified by Mengting Qiu on 2025/07/03 14:48

From version 148.14
edited by Xiaoling
on 2022/06/17 15:06
Change comment: There is no comment for this version
To version 148.3
edited by Xiaoling
on 2022/06/17 15:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -22,9 +22,6 @@
22 22  (% _mstvisible="1" %)
23 23  (((
24 24  (% _msthash="506051" _msttexthash="24333127" _mstvisible="2" %)
25 -
26 -
27 -(% _msthash="506051" _msttexthash="24333127" _mstvisible="2" %)
28 28  The Dragino LHT65N Temperature & Humidity sensor is a Long Range LoRaWAN Sensor. It includes a (% _mstvisible="4" style="color:#4f81bd" %)**built-in Temperature & Humidity sensor**(%%) and has an external sensor connector to connect to an external (% _mstvisible="4" style="color:#4f81bd" %)**Temperature Sensor**(% _mstvisible="3" %)**.**
29 29  )))
30 30  
... ... @@ -77,9 +77,6 @@
77 77  * Tri-color LED to indicate working status
78 78  * Datalog feature
79 79  
80 -
81 -
82 -
83 83  (% _mstvisible="1" %)
84 84  == (% _msthash="323570" _msttexthash="297635" _mstvisible="3" %)1.3 Specification(%%) ==
85 85  
... ... @@ -208,8 +208,8 @@
208 208  The LHT65N has two working modes:
209 209  
210 210  (% _mstvisible="1" %)
211 -* (% style="color:blue" %)**Deep Sleep Mode**(%%): LHT65N doesn’t have any LoRaWAN activation. This mode is used for storage and shipping to save battery life.
212 -* (% style="color:blue" %)**Working Mode**(%%):  In this mode, LHT65N works as LoRaWAN Sensor mode to Join LoRaWAN network and send out the sensor data to the server. Between each sampling/tx/rx periodically, LHT65N will be in STOP mode (IDLE mode), in STOP mode, LHT65N has the same power consumption as Deep Sleep mode. 
205 +* **Deep Sleep Mode**: LHT65N doesn’t have any LoRaWAN activation. This mode is used for storage and shipping to save battery life.
206 +* **Working Mode**:  In this mode, LHT65N works as LoRaWAN Sensor mode to Join LoRaWAN network and send out the sensor data to the server. Between each sampling/tx/rx periodically, LHT65 will be in STOP mode (IDLE mode), in STOP mode, LHT65N has the same power consumption as Deep Sleep mode. 
213 213  
214 214  (% _mstvisible="1" %)
215 215  (((
... ... @@ -370,7 +370,6 @@
370 370  
371 371  
372 372  
373 -
374 374  (% _mstvisible="1" %)
375 375  === (% _msthash="360269" _msttexthash="333762" _mstvisible="3" %)2.4.1 Decoder in TTN V3(%%) ===
376 376  
... ... @@ -409,7 +409,6 @@
409 409  
410 410  
411 411  
412 -
413 413  (% _mstvisible="1" %)
414 414  === (% _msthash="600769" _msttexthash="565838" _mstvisible="3" %)2.4.3 Built-in Temperature(%%) ===
415 415  
... ... @@ -426,8 +426,6 @@
426 426  * Temperature:  (0xF5C6-65536)/100=-26.18℃
427 427  
428 428  
429 -
430 -
431 431  (% _mstvisible="1" %)
432 432  === (% _msthash="475891" _msttexthash="445120" _mstvisible="3" %)2.4.4 Built-in Humidity(%%) ===
433 433  
... ... @@ -438,8 +438,6 @@
438 438  * Humidity:    0x025C/10=60.4%
439 439  
440 440  
441 -
442 -
443 443  (% _mstvisible="1" %)
444 444  === (% _msthash="116532" _msttexthash="87958" _mstvisible="3" %)2.4.5 Ext #(%%) ===
445 445  
... ... @@ -608,8 +608,6 @@
608 608  * Unix Time Request:1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this)
609 609  
610 610  
611 -
612 -
613 613  (% _mstvisible="1" %)
614 614  == (% _msthash="487097" _msttexthash="454818" _mstvisible="3" %)2.5 Show data on Datacake(%%) ==
615 615  
... ... @@ -672,6 +672,7 @@
672 672  1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range.
673 673  1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover.
674 674  
661 +
675 675  (% _mstvisible="1" %)
676 676  === (% _msthash="369915" _msttexthash="342797" _mstvisible="3" %)2.6.2 Unix TimeStamp(%%) ===
677 677  
... ... @@ -1187,6 +1187,7 @@
1187 1187  * -55°C to 125°C
1188 1188  * Working voltage 2.35v ~~ 5v
1189 1189  
1177 +
1190 1190  (% _mstvisible="1" style="text-align: left;" %)
1191 1191  = (% _msthash="1940107" _msttexthash="1714063" _mstvisible="3" %)4. Configure LHT65N via AT command or LoRaWAN downlink(%%) =
1192 1192  
... ... @@ -1402,6 +1402,7 @@
1402 1402  * 0xA800  **~-~->** AT+PID=0
1403 1403  * 0xA801     **~-~->** AT+PID=1
1404 1404  
1393 +
1405 1405  (% _mstvisible="1" style="text-align: left;" %)
1406 1406  == (% _msthash="266344" _msttexthash="242879" _mstvisible="3" %)4.4 Set Password(%%) ==
1407 1407  
... ... @@ -1473,6 +1473,7 @@
1473 1473  (% _mstvisible="1" %)
1474 1474  * There is no downlink command to set to Sleep mode.
1475 1475  
1465 +
1476 1476  (% _mstvisible="1" %)
1477 1477  == (% _msthash="336557" _msttexthash="309712" _mstvisible="3" %)4.7 Set system time(%%) ==
1478 1478  
... ... @@ -1607,6 +1607,7 @@
1607 1607  (% _mstvisible="1" %)
1608 1608  * Example: 0xA301 ~/~/Same as AT+CLRDTA
1609 1609  
1600 +
1610 1610  (% _mstvisible="1" %)
1611 1611  == (% _msthash="740532" _msttexthash="701363" _mstvisible="3" %)4.13 Auto Send None-ACK messages(%%) ==
1612 1612  
... ... @@ -1630,6 +1630,7 @@
1630 1630  (% _mstvisible="1" %)
1631 1631  * Example: 0x3401 ~/~/Same as AT+PNACKMD=1
1632 1632  
1624 +
1633 1633  (% _mstvisible="1" %)
1634 1634  = (% _msthash="568737" _msttexthash="502827" _mstvisible="3" %)5. Battery & How to replace(%%) =
1635 1635  
... ... @@ -2119,6 +2119,11 @@
2119 2119  )))
2120 2120  * (% _mstvisible="3" %)
2121 2121  (((
2114 +(% _msthash="903337" _msttexthash="242567" _mstvisible="4" %)
2115 +Program cable x 1
2116 +)))
2117 +* (% _mstvisible="3" %)
2118 +(((
2122 2122  (% _msthash="903338" _msttexthash="544167" _mstvisible="4" %)
2123 2123  Optional external sensor
2124 2124  )))
... ... @@ -2153,8 +2153,6 @@
2153 2153  
2154 2154  * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/home/Products_Public_Document/LoRaWAN%20End%20Node/LHT65N%20Temperature%20%26%20Humidity%20Sensor||_msthash="504975" _msttexthash="51420512"]]
2155 2155  
2156 -
2157 -
2158 2158  = (% _msthash="216320" _msttexthash="10002096" %)10. (%%)FCC Warning =
2159 2159  
2160 2160  (% _mstvisible="1" %)