Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2025/07/03 14:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,9 +22,6 @@ 22 22 (% _mstvisible="1" %) 23 23 ((( 24 24 (% _msthash="506051" _msttexthash="24333127" _mstvisible="2" %) 25 - 26 - 27 -(% _msthash="506051" _msttexthash="24333127" _mstvisible="2" %) 28 28 The Dragino LHT65N Temperature & Humidity sensor is a Long Range LoRaWAN Sensor. It includes a (% _mstvisible="4" style="color:#4f81bd" %)**built-in Temperature & Humidity sensor**(%%) and has an external sensor connector to connect to an external (% _mstvisible="4" style="color:#4f81bd" %)**Temperature Sensor**(% _mstvisible="3" %)**.** 29 29 ))) 30 30 ... ... @@ -77,9 +77,6 @@ 77 77 * Tri-color LED to indicate working status 78 78 * Datalog feature 79 79 80 - 81 - 82 - 83 83 (% _mstvisible="1" %) 84 84 == (% _msthash="323570" _msttexthash="297635" _mstvisible="3" %)1.3 Specification(%%) == 85 85 ... ... @@ -208,8 +208,8 @@ 208 208 The LHT65N has two working modes: 209 209 210 210 (% _mstvisible="1" %) 211 -* (% style="color:blue" %)**Deep Sleep Mode**(%%): LHT65N doesn’t have any LoRaWAN activation. This mode is used for storage and shipping to save battery life.212 -* (% style="color:blue" %)**Working Mode**(%%):Nwill be in STOP mode (IDLE mode), in STOP mode, LHT65N has the same power consumption as Deep Sleep mode.205 +* **Deep Sleep Mode**: LHT65N doesn’t have any LoRaWAN activation. This mode is used for storage and shipping to save battery life. 206 +* **Working Mode**: In this mode, LHT65N works as LoRaWAN Sensor mode to Join LoRaWAN network and send out the sensor data to the server. Between each sampling/tx/rx periodically, LHT65 will be in STOP mode (IDLE mode), in STOP mode, LHT65N has the same power consumption as Deep Sleep mode. 213 213 214 214 (% _mstvisible="1" %) 215 215 ((( ... ... @@ -247,7 +247,7 @@ 247 247 Each LHT65N is shipped with a sticker with its device EUI, APP Key and APP EUI as below: 248 248 249 249 (% _mstvisible="1" %) 250 -[[image:image-20220 617150003-1.jpeg]]244 +[[image:image-20220522232812-2.png||_mstalt="428467" _mstvisible="3" height="219" width="279"]] 251 251 252 252 (% _msthash="315244" _msttexthash="3659149" _mstvisible="1" %) 253 253 User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot: ... ... @@ -368,9 +368,6 @@ 368 368 * The 7th byte (EXT #): defines the external sensor model. 369 369 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won’t be these four bytes.) 370 370 371 - 372 - 373 - 374 374 (% _mstvisible="1" %) 375 375 === (% _msthash="360269" _msttexthash="333762" _mstvisible="3" %)2.4.1 Decoder in TTN V3(%%) === 376 376 ... ... @@ -407,9 +407,6 @@ 407 407 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 408 408 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 409 409 410 - 411 - 412 - 413 413 (% _mstvisible="1" %) 414 414 === (% _msthash="600769" _msttexthash="565838" _mstvisible="3" %)2.4.3 Built-in Temperature(%%) === 415 415 ... ... @@ -425,9 +425,6 @@ 425 425 (% _mstvisible="1" %) 426 426 * Temperature: (0xF5C6-65536)/100=-26.18℃ 427 427 428 - 429 - 430 - 431 431 (% _mstvisible="1" %) 432 432 === (% _msthash="475891" _msttexthash="445120" _mstvisible="3" %)2.4.4 Built-in Humidity(%%) === 433 433 ... ... @@ -437,9 +437,6 @@ 437 437 (% _mstvisible="1" %) 438 438 * Humidity: 0x025C/10=60.4% 439 439 440 - 441 - 442 - 443 443 (% _mstvisible="1" %) 444 444 === (% _msthash="116532" _msttexthash="87958" _mstvisible="3" %)2.4.5 Ext #(%%) === 445 445 ... ... @@ -1098,19 +1098,19 @@ 1098 1098 (% _mstvisible="1" class="box infomessage" %) 1099 1099 ((( 1100 1100 (% _msthash="506086" _msttexthash="2193529" _mstvisible="2" style="text-align: left;" %) 1101 -(% _istranslated="1" _mstmutation="1" _mstvisible="4" %)**AT+WMOD=1**(%%): 1083 +(% _istranslated="1" _mstmutation="1" _mstvisible="4" %)**AT+WMOD=1**(%%): Enable/disable alarm mode. (0: Disabled, 1: Enabled) 1102 1102 1103 1103 (% _msthash="506087" _msttexthash="3671265" _mstvisible="2" style="text-align: left;" %) 1104 -(% _istranslated="1" _mstvisible="4" %)**AT+CITEMP=1**(%%): 1086 +(% _istranslated="1" _mstvisible="4" %)**AT+CITEMP=1**(%%): The interval between checking the alarm temperature. (In minutes) 1105 1105 1106 1106 (% _msthash="506088" _msttexthash="3310437" _mstvisible="2" style="text-align: left;" %) 1107 -(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP**(%%): 1089 +(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP**(%%): Gets or sets the alarm range of the internal temperature sensor 1108 1108 1109 1109 (% _mstvisible="2" style="text-align: left;" %) 1110 -(% _istranslated="1" _mstmutation="1" %)**AT+ARTEMP=? **(%%): 1092 +(% _istranslated="1" _mstmutation="1" %)**AT+ARTEMP=? **(%%): Gets the alarm range of the internal temperature sensor(% _mstvisible="3" style="display:none" %) 1111 1111 1112 1112 (% _msthash="506089" _msttexthash="3590067" _mstvisible="2" style="text-align: left;" %) 1113 -(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP=45,105**(%%): 1095 +(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP=45,105**(%%): Set the internal temperature sensor alarm range from 45 to 105. 1114 1114 ))) 1115 1115 1116 1116 ... ... @@ -1153,6 +1153,9 @@ 1153 1153 For each success downlink, the PURPLE LED will blink once 1154 1154 1155 1155 1138 + 1139 + 1140 +(% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %) 1156 1156 1157 1157 ))) 1158 1158 ... ... @@ -1256,7 +1256,7 @@ 1256 1256 (% _mstvisible="1" %) 1257 1257 ((( 1258 1258 (% _mstvisible="2" style="text-align: left;" %) 1259 -(% _mstvisible="3" style="color:#4f81bd" %)* (% _msthash="506 249" _mstmutation="1" _msttexthash="317850" _mstvisible="4" style="color:#4f81bd" %)**Commands special design for LHT65N**1244 +(% _mstvisible="3" style="color:#4f81bd" %)* (% _msthash="506054" _msttexthash="792038" %)**Commands special design for LHT65N** 1260 1260 ))) 1261 1261 1262 1262 (% _mstvisible="1" %) ... ... @@ -1709,7 +1709,7 @@ 1709 1709 1710 1710 ((( 1711 1711 (% _msthash="736726" _msttexthash="67213055" %) 1712 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**) (%%)to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 1697 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.htmlml]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**) (%%)to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 1713 1713 ))) 1714 1714 1715 1715 ((( ... ... @@ -1963,11 +1963,14 @@ 1963 1963 1964 1964 [[image:image-20220615153355-1.png]] 1965 1965 1966 -(% style="background-color:yellow" %)**1 < - -> GND < - -> Black** 1951 +(% _msthash="506138" _msttexthash="243997" %) 1952 +* (% style="background-color:yellow" %)1 < - -> GND < - -> Black 1967 1967 1968 -(% style="background-color:yellow" %)**5 < - -> RXD < - -> White** 1954 +(% _msthash="506139" _msttexthash="257166" %) 1955 +* (% style="background-color:yellow" %)5 < - -> RXD < - -> White 1969 1969 1970 -(% style="background-color:yellow" %)**9 < - -> TXD < - -> Green** 1957 +(% _msthash="506140" _msttexthash="253799" %) 1958 +* (% style="background-color:yellow" %)9 < - -> TXD < - -> Green 1971 1971 1972 1972 [[image:image-20220615153914-2.jpeg||height="608" width="456"]] 1973 1973 ... ... @@ -1975,7 +1975,7 @@ 1975 1975 ((( 1976 1976 (% _msthash="736728" _msttexthash="67213055" %) 1977 1977 ((( 1978 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:red" %)**123456**)(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 1966 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.htmlml]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:red" %)**123456**)(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 1979 1979 ))) 1980 1980 ))) 1981 1981 ... ... @@ -1989,15 +1989,22 @@ 1989 1989 ))) 1990 1990 1991 1991 1980 + 1992 1992 == 6.5 How to use TTL-USB to connect PC to upgrade firmware? == 1993 1993 1994 1994 [[image:image-20220615153355-1.png]] 1995 1995 1996 -(% style="background-color:yellow" %)**4 < - -> 3.3V < - -> Blue** 1985 +(% _msthash="506141" _msttexthash="231309" %) 1986 +* 1987 +** (% style="background-color:yellow" %)4 < - -> 3.3V < - -> Blue 1997 1997 1998 -(% style="background-color:yellow" %)**5 < - -> RXD < - -> White** 1989 +(% _msthash="506142" _msttexthash="257166" %) 1990 +* 1991 +** (% style="background-color:yellow" %)5 < - -> RXD < - -> White 1999 1999 2000 -(% style="background-color:yellow" %)**9 < - -> TXD < - -> Green** 1993 +(% _msthash="506143" _msttexthash="253799" %) 1994 +* 1995 +** (% style="background-color:yellow" %)9 < - -> TXD < - -> Green 2001 2001 2002 2002 Use after connection, ground wire(1 < - -> GND < - -> Black) for 1s and then pull it out.Then restart the device. 2003 2003 ... ... @@ -2017,7 +2017,7 @@ 2017 2017 [[image:image-20220615171334-6.png]] 2018 2018 2019 2019 2020 -(% _istranslated="1" _mstmutation="1" %)**Step4:**(%%)Click Start 2015 +(% _istranslated="1" _mstmutation="1" %)**Step4:**(%%)Click Start 2021 2021 2022 2022 2023 2023 ))) ... ... @@ -2116,6 +2116,11 @@ 2116 2116 ))) 2117 2117 * (% _mstvisible="3" %) 2118 2118 ((( 2114 +(% _msthash="903337" _msttexthash="242567" _mstvisible="4" %) 2115 +Program cable x 1 2116 +))) 2117 +* (% _mstvisible="3" %) 2118 +((( 2119 2119 (% _msthash="903338" _msttexthash="544167" _mstvisible="4" %) 2120 2120 Optional external sensor 2121 2121 ))) ... ... @@ -2150,8 +2150,6 @@ 2150 2150 2151 2151 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/home/Products_Public_Document/LoRaWAN%20End%20Node/LHT65N%20Temperature%20%26%20Humidity%20Sensor||_msthash="504975" _msttexthash="51420512"]] 2152 2152 2153 - 2154 - 2155 2155 = (% _msthash="216320" _msttexthash="10002096" %)10. (%%)FCC Warning = 2156 2156 2157 2157 (% _mstvisible="1" %)
- image-20220617150003-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.5 KB - Content