Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2025/07/03 14:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,9 +22,6 @@ 22 22 (% _mstvisible="1" %) 23 23 ((( 24 24 (% _msthash="506051" _msttexthash="24333127" _mstvisible="2" %) 25 - 26 - 27 -(% _msthash="506051" _msttexthash="24333127" _mstvisible="2" %) 28 28 The Dragino LHT65N Temperature & Humidity sensor is a Long Range LoRaWAN Sensor. It includes a (% _mstvisible="4" style="color:#4f81bd" %)**built-in Temperature & Humidity sensor**(%%) and has an external sensor connector to connect to an external (% _mstvisible="4" style="color:#4f81bd" %)**Temperature Sensor**(% _mstvisible="3" %)**.** 29 29 ))) 30 30 ... ... @@ -77,9 +77,6 @@ 77 77 * Tri-color LED to indicate working status 78 78 * Datalog feature 79 79 80 - 81 - 82 - 83 83 (% _mstvisible="1" %) 84 84 == (% _msthash="323570" _msttexthash="297635" _mstvisible="3" %)1.3 Specification(%%) == 85 85 ... ... @@ -208,8 +208,8 @@ 208 208 The LHT65N has two working modes: 209 209 210 210 (% _mstvisible="1" %) 211 -* (% style="color:blue" %)**Deep Sleep Mode**(%%): LHT65N doesn’t have any LoRaWAN activation. This mode is used for storage and shipping to save battery life.212 -* (% style="color:blue" %)**Working Mode**(%%):Nwill be in STOP mode (IDLE mode), in STOP mode, LHT65N has the same power consumption as Deep Sleep mode.205 +* **Deep Sleep Mode**: LHT65N doesn’t have any LoRaWAN activation. This mode is used for storage and shipping to save battery life. 206 +* **Working Mode**: In this mode, LHT65N works as LoRaWAN Sensor mode to Join LoRaWAN network and send out the sensor data to the server. Between each sampling/tx/rx periodically, LHT65 will be in STOP mode (IDLE mode), in STOP mode, LHT65N has the same power consumption as Deep Sleep mode. 213 213 214 214 (% _mstvisible="1" %) 215 215 ((( ... ... @@ -247,7 +247,7 @@ 247 247 Each LHT65N is shipped with a sticker with its device EUI, APP Key and APP EUI as below: 248 248 249 249 (% _mstvisible="1" %) 250 -[[image:image-20220 617150003-1.jpeg]]244 +[[image:image-20220522232812-2.png||_mstalt="428467" _mstvisible="3" height="219" width="279"]] 251 251 252 252 (% _msthash="315244" _msttexthash="3659149" _mstvisible="1" %) 253 253 User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot: ... ... @@ -368,9 +368,6 @@ 368 368 * The 7th byte (EXT #): defines the external sensor model. 369 369 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won’t be these four bytes.) 370 370 371 - 372 - 373 - 374 374 (% _mstvisible="1" %) 375 375 === (% _msthash="360269" _msttexthash="333762" _mstvisible="3" %)2.4.1 Decoder in TTN V3(%%) === 376 376 ... ... @@ -407,9 +407,6 @@ 407 407 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 408 408 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 409 409 410 - 411 - 412 - 413 413 (% _mstvisible="1" %) 414 414 === (% _msthash="600769" _msttexthash="565838" _mstvisible="3" %)2.4.3 Built-in Temperature(%%) === 415 415 ... ... @@ -1092,19 +1092,19 @@ 1092 1092 (% _mstvisible="1" class="box infomessage" %) 1093 1093 ((( 1094 1094 (% _msthash="506086" _msttexthash="2193529" _mstvisible="2" style="text-align: left;" %) 1095 -(% _istranslated="1" _mstmutation="1" _mstvisible="4" %)**AT+WMOD=1**(%%): 1083 +(% _istranslated="1" _mstmutation="1" _mstvisible="4" %)**AT+WMOD=1**(%%): Enable/disable alarm mode. (0: Disabled, 1: Enabled) 1096 1096 1097 1097 (% _msthash="506087" _msttexthash="3671265" _mstvisible="2" style="text-align: left;" %) 1098 -(% _istranslated="1" _mstvisible="4" %)**AT+CITEMP=1**(%%): 1086 +(% _istranslated="1" _mstvisible="4" %)**AT+CITEMP=1**(%%): The interval between checking the alarm temperature. (In minutes) 1099 1099 1100 1100 (% _msthash="506088" _msttexthash="3310437" _mstvisible="2" style="text-align: left;" %) 1101 -(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP**(%%): 1089 +(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP**(%%): Gets or sets the alarm range of the internal temperature sensor 1102 1102 1103 1103 (% _mstvisible="2" style="text-align: left;" %) 1104 -(% _istranslated="1" _mstmutation="1" %)**AT+ARTEMP=? **(%%): 1092 +(% _istranslated="1" _mstmutation="1" %)**AT+ARTEMP=? **(%%): Gets the alarm range of the internal temperature sensor(% _mstvisible="3" style="display:none" %) 1105 1105 1106 1106 (% _msthash="506089" _msttexthash="3590067" _mstvisible="2" style="text-align: left;" %) 1107 -(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP=45,105**(%%): 1095 +(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP=45,105**(%%): Set the internal temperature sensor alarm range from 45 to 105. 1108 1108 ))) 1109 1109 1110 1110 ... ... @@ -1147,6 +1147,9 @@ 1147 1147 For each success downlink, the PURPLE LED will blink once 1148 1148 1149 1149 1138 + 1139 + 1140 +(% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %) 1150 1150 1151 1151 ))) 1152 1152 ... ... @@ -1250,7 +1250,7 @@ 1250 1250 (% _mstvisible="1" %) 1251 1251 ((( 1252 1252 (% _mstvisible="2" style="text-align: left;" %) 1253 -(% _mstvisible="3" style="color:#4f81bd" %)* (% _msthash="506 249" _mstmutation="1" _msttexthash="317850" _mstvisible="4" style="color:#4f81bd" %)**Commands special design for LHT65N**1244 +(% _mstvisible="3" style="color:#4f81bd" %)* (% _msthash="506054" _msttexthash="792038" %)**Commands special design for LHT65N** 1254 1254 ))) 1255 1255 1256 1256 (% _mstvisible="1" %) ... ... @@ -1703,7 +1703,7 @@ 1703 1703 1704 1704 ((( 1705 1705 (% _msthash="736726" _msttexthash="67213055" %) 1706 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**) (%%)to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 1697 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.htmlml]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**) (%%)to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 1707 1707 ))) 1708 1708 1709 1709 ((( ... ... @@ -1957,11 +1957,14 @@ 1957 1957 1958 1958 [[image:image-20220615153355-1.png]] 1959 1959 1960 -(% style="background-color:yellow" %)**1 < - -> GND < - -> Black** 1951 +(% _msthash="506138" _msttexthash="243997" %) 1952 +* (% style="background-color:yellow" %)1 < - -> GND < - -> Black 1961 1961 1962 -(% style="background-color:yellow" %)**5 < - -> RXD < - -> White** 1954 +(% _msthash="506139" _msttexthash="257166" %) 1955 +* (% style="background-color:yellow" %)5 < - -> RXD < - -> White 1963 1963 1964 -(% style="background-color:yellow" %)**9 < - -> TXD < - -> Green** 1957 +(% _msthash="506140" _msttexthash="253799" %) 1958 +* (% style="background-color:yellow" %)9 < - -> TXD < - -> Green 1965 1965 1966 1966 [[image:image-20220615153914-2.jpeg||height="608" width="456"]] 1967 1967 ... ... @@ -1969,7 +1969,7 @@ 1969 1969 ((( 1970 1970 (% _msthash="736728" _msttexthash="67213055" %) 1971 1971 ((( 1972 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:red" %)**123456**)(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 1966 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.htmlml]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:red" %)**123456**)(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 1973 1973 ))) 1974 1974 ))) 1975 1975 ... ... @@ -1983,15 +1983,22 @@ 1983 1983 ))) 1984 1984 1985 1985 1980 + 1986 1986 == 6.5 How to use TTL-USB to connect PC to upgrade firmware? == 1987 1987 1988 1988 [[image:image-20220615153355-1.png]] 1989 1989 1990 -(% style="background-color:yellow" %)**4 < - -> 3.3V < - -> Blue** 1985 +(% _msthash="506141" _msttexthash="231309" %) 1986 +* 1987 +** (% style="background-color:yellow" %)4 < - -> 3.3V < - -> Blue 1991 1991 1992 -(% style="background-color:yellow" %)**5 < - -> RXD < - -> White** 1989 +(% _msthash="506142" _msttexthash="257166" %) 1990 +* 1991 +** (% style="background-color:yellow" %)5 < - -> RXD < - -> White 1993 1993 1994 -(% style="background-color:yellow" %)**9 < - -> TXD < - -> Green** 1993 +(% _msthash="506143" _msttexthash="253799" %) 1994 +* 1995 +** (% style="background-color:yellow" %)9 < - -> TXD < - -> Green 1995 1995 1996 1996 Use after connection, ground wire(1 < - -> GND < - -> Black) for 1s and then pull it out.Then restart the device. 1997 1997 ... ... @@ -2011,7 +2011,7 @@ 2011 2011 [[image:image-20220615171334-6.png]] 2012 2012 2013 2013 2014 -(% _istranslated="1" _mstmutation="1" %)**Step4:**(%%)Click Start 2015 +(% _istranslated="1" _mstmutation="1" %)**Step4:**(%%)Click Start 2015 2015 2016 2016 2017 2017 ))) ... ... @@ -2110,6 +2110,11 @@ 2110 2110 ))) 2111 2111 * (% _mstvisible="3" %) 2112 2112 ((( 2114 +(% _msthash="903337" _msttexthash="242567" _mstvisible="4" %) 2115 +Program cable x 1 2116 +))) 2117 +* (% _mstvisible="3" %) 2118 +((( 2113 2113 (% _msthash="903338" _msttexthash="544167" _mstvisible="4" %) 2114 2114 Optional external sensor 2115 2115 ))) ... ... @@ -2144,8 +2144,6 @@ 2144 2144 2145 2145 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/home/Products_Public_Document/LoRaWAN%20End%20Node/LHT65N%20Temperature%20%26%20Humidity%20Sensor||_msthash="504975" _msttexthash="51420512"]] 2146 2146 2147 - 2148 - 2149 2149 = (% _msthash="216320" _msttexthash="10002096" %)10. (%%)FCC Warning = 2150 2150 2151 2151 (% _mstvisible="1" %)
- image-20220617150003-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.5 KB - Content