1948 1948  
1949 1949  [[image:image-20220615153355-1.png]]
1950 1950  
1951 -(% _msthash="506138" _msttexthash="243997" %)
1952 -* (% style="background-color:yellow" %)1 < - -> GND  < - ->  Black
1951 +(% style="background-color:yellow" %)**1 < - -> GND  < - ->  Black**
1953 1953  
1954 -(% _msthash="506139" _msttexthash="257166" %)
1955 -* (% style="background-color:yellow" %)5 < - ->  RXD  < - ->  White
1953 +(% style="background-color:yellow" %)**5 < - ->  RXD  < - ->  White**
1956 1956  
1957 -(% _msthash="506140" _msttexthash="253799" %)
1958 -* (% style="background-color:yellow" %)9 < - ->  TXD  < - ->  Green
1955 +(% style="background-color:yellow" %)**9 < - ->  TXD  < - ->  Green**
1959 1959  
1960 1960  [[image:image-20220615153914-2.jpeg||height="608" width="456"]]
1961 1961  
1959 +
1962 1962  (((
1963 1963  (% _msthash="736728" _msttexthash="67213055" %)
1964 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.htmlml]], SecureCRT) baud rate to
1965 -(% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:
1966 -(% style="color:red" %)**123456**)(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
1962 +(((
1963 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.htmlml]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:red" %)**123456**)(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
1967 1967  )))
1965 +)))
1968 1968  
1969 1969  (((
1970 1970  (% _msthash="736729" _msttexthash="1907009" %)
... ... @@ -1976,22 +1976,15 @@
1976 1976  )))
1977 1977  
1978 1978  
1979 -
1980 1980  == 6.5 How to use TTL-USB to connect PC to upgrade firmware? ==
1981 1981  
1982 1982  [[image:image-20220615153355-1.png]]
1983 1983  
1984 -(% _msthash="506141" _msttexthash="231309" %)
1985 -*
1986 -** (% style="background-color:yellow" %)4  < - ->  3.3V  < - ->  Blue
1981 +(% style="background-color:yellow" %)**4  < - ->  3.3V  < - ->  Blue**
1987 1987  
1988 -(% _msthash="506142" _msttexthash="257166" %)
1989 -*
1990 -** (% style="background-color:yellow" %)5 < - ->  RXD  < - ->  White
1983 +(% style="background-color:yellow" %)**5 < - ->  RXD  < - ->  White**
1991 1991  
1992 -(% _msthash="506143" _msttexthash="253799" %)
1993 -*
1994 -** (% style="background-color:yellow" %)9 < - ->  TXD  < - ->  Green
1985 +(% style="background-color:yellow" %)**9 < - ->  TXD  < - ->  Green**
1995 1995  
1996 1996  Use after connection, ground wire(1 < - -> GND  < - ->  Black) for 1s and then pull it out.Then restart the device.