Last modified by Mengting Qiu on 2025/07/03 14:48

From version 147.5
edited by Xiaoling
on 2022/06/17 14:46
Change comment: There is no comment for this version
To version 147.3
edited by Xiaoling
on 2022/06/17 14:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1683,18 +1683,18 @@
1683 1683  (% _msthash="506061" _msttexthash="170755" %)**Connection:**
1684 1684  
1685 1685  (% _msthash="506062" _msttexthash="1187732" %)
1686 -** (% style="background-color:yellow" %)USB to TTL GND <~-~->GND(%%)**
1686 +** USB to TTL GND <~-~->GND**
1687 1687  
1688 -(% _msthash="506063" _msttexthash="1158313" %)**✓  **(% style="background-color:yellow" %)**USB to TTL RXD <~-~-> D+**
1688 +(% _msthash="506063" _msttexthash="1158313" %)**✓ USB to TTL RXD <~-~-> D+**
1689 1689  
1690 -(% _msthash="506064" _msttexthash="1175629" %)**✓  **(% style="background-color:yellow" %)**USB to TTL TXD <~-~-> A11**
1690 +(% _msthash="506064" _msttexthash="1175629" %)**✓ USB to TTL TXD <~-~-> A11**
1691 1691  
1692 -(% _msthash="506065" _msttexthash="1164696" %)**✓  **(% style="background-color:yellow" %)**USB to TTL 3.3V <~-~-> D-**
1692 +(% _msthash="506065" _msttexthash="1164696" %)**✓ USB to TTL 3.3V <~-~-> D-**
1693 1693  
1694 1694  
1695 1695  (((
1696 1696  (% _msthash="736726" _msttexthash="67213055" %)
1697 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.htmlml]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**) (%%)to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
1697 +In PC, User needs to set serial tool(such as **putty**, SecureCRT) baud rate to **9600** to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:**123456**) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
1698 1698  )))
1699 1699  
1700 1700  (((
... ... @@ -1911,38 +1911,32 @@
1911 1911  (% _msthash="506132" _msttexthash="337922" %)
1912 1912  Downlink commands:
1913 1913  
1914 -
1915 1915  (% _msthash="506133" _msttexthash="33046" %)
1916 -**TTN:**
1915 +TTN:
1917 1917  
1918 1918  [[image:image-20220615092124-2.png||_mstalt="429221" height="843" width="893"]]
1919 1919  
1920 -
1921 1921  (% _msthash="506134" _msttexthash="11113791" %)
1922 -**Helium:**
1920 +Helium:
1923 1923  
1924 1924  [[image:image-20220615092551-3.png||_mstalt="430794" height="556" width="1097"]]
1925 1925  
1926 -
1927 1927  (% _msthash="506135" _msttexthash="4159844" %)
1928 -**Chirpstack:The downlink window will not be displayed until the network is accessed**
1925 +Chirpstack:The downlink window will not be displayed until the network is accessed
1929 1929  
1930 1930  [[image:image-20220615094850-6.png||_mstalt="433082"]]
1931 1931  
1932 1932  [[image:image-20220615094904-7.png||_mstalt="433485" height="329" width="1067"]]
1933 1933  
1934 -
1935 1935  (% _msthash="506136" _msttexthash="39286" %)
1936 -**Aws:**
1932 +Aws:
1937 1937  
1938 1938  [[image:image-20220615092939-4.png||_mstalt="434460" height="532" width="1062"]]
1939 1939  
1940 -
1941 1941  == (% _msthash="1220570" _msttexthash="33199257" %)6.3 How to change the uplink interval?(%%) ==
1942 1942  
1943 1943  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_msthash="506137" _msttexthash="5712018"]]
1944 1944  
1945 -
1946 1946  (% _msthash="536757" _msttexthash="1874951" %)
1947 1947  == 6.4 How to use TTL-USB to connect a PC to input AT commands? ==
1948 1948  
... ... @@ -1949,21 +1949,19 @@
1949 1949  [[image:image-20220615153355-1.png]]
1950 1950  
1951 1951  (% _msthash="506138" _msttexthash="243997" %)
1952 -* (% style="background-color:yellow" %)1 < - -> GND  < - ->  Black
1946 +1 < - -> GND  < - ->  Black
1953 1953  
1954 1954  (% _msthash="506139" _msttexthash="257166" %)
1955 -* (% style="background-color:yellow" %)5 < - ->  RXD  < - ->  White
1949 +5 < - ->  RXD  < - ->  White
1956 1956  
1957 1957  (% _msthash="506140" _msttexthash="253799" %)
1958 -* (% style="background-color:yellow" %)9 < - ->  TXD  < - ->  Green
1952 +9 < - ->  TXD  < - ->  Green
1959 1959  
1960 1960  [[image:image-20220615153914-2.jpeg||height="608" width="456"]]
1961 1961  
1962 1962  (((
1963 1963  (% _msthash="736728" _msttexthash="67213055" %)
1964 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.htmlml]], SecureCRT) baud rate to
1965 -(% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:
1966 -(% style="color:red" %)**123456**)(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
1958 +In PC, User needs to set serial tool(such as **putty**, SecureCRT) baud rate to **9600** to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:**123456**) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
1967 1967  )))
1968 1968  
1969 1969  (((
... ... @@ -1975,23 +1975,19 @@
1975 1975  
1976 1976  )))
1977 1977  
1978 -
1979 -
1970 +(% _msthash="536758" _msttexthash="1832428" %)
1980 1980  == 6.5 How to use TTL-USB to connect PC to upgrade firmware? ==
1981 1981  
1982 1982  [[image:image-20220615153355-1.png]]
1983 1983  
1984 1984  (% _msthash="506141" _msttexthash="231309" %)
1985 -*
1986 -** (% style="background-color:yellow" %)4  < - ->  3.3V  < - ->  Blue
1976 +4  < - ->  3.3V  < - ->  Blue
1987 1987  
1988 1988  (% _msthash="506142" _msttexthash="257166" %)
1989 -*
1990 -** (% style="background-color:yellow" %)5 < - ->  RXD  < - ->  White
1979 +5 < - ->  RXD  < - ->  White
1991 1991  
1992 1992  (% _msthash="506143" _msttexthash="253799" %)
1993 -*
1994 -** (% style="background-color:yellow" %)9 < - ->  TXD  < - ->  Green
1982 +9 < - ->  TXD  < - ->  Green
1995 1995  
1996 1996  Use after connection, ground wire(1 < - -> GND  < - ->  Black) for 1s and then pull it out.Then restart the device.
1997 1997  
... ... @@ -2035,42 +2035,42 @@
2035 2035  * (% _mstvisible="3" %)
2036 2036  (((
2037 2037  (% _msthash="903327" _msttexthash="393341" _mstvisible="4" %)
2038 -(% _mstvisible="6" style="color:#4f81bd" %)** **(% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
2026 +(% _mstvisible="6" style="color:#4f81bd" %)** AS923**(%%): LoRaWAN AS923 band
2039 2039  )))
2040 2040  * (% _mstvisible="3" %)
2041 2041  (((
2042 2042  (% _msthash="903328" _msttexthash="394576" _mstvisible="4" %)
2043 -(% _mstvisible="6" style="color:#4f81bd" %)** **(% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
2031 +(% _mstvisible="6" style="color:#4f81bd" %)** AU915**(%%): LoRaWAN AU915 band
2044 2044  )))
2045 2045  * (% _mstvisible="3" %)
2046 2046  (((
2047 2047  (% _msthash="903329" _msttexthash="393913" _mstvisible="4" %)
2048 -(% _mstvisible="6" style="color:#4f81bd" %)** **(% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
2036 +(% _mstvisible="6" style="color:#4f81bd" %)** EU433**(%%): LoRaWAN EU433 band
2049 2049  )))
2050 2050  * (% _mstvisible="3" %)
2051 2051  (((
2052 2052  (% _msthash="903330" _msttexthash="399087" _mstvisible="4" %)
2053 -(% _mstvisible="6" style="color:#4f81bd" %)** **(% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
2041 +(% _mstvisible="6" style="color:#4f81bd" %)** EU868**(%%): LoRaWAN EU868 band
2054 2054  )))
2055 2055  * (% _mstvisible="3" %)
2056 2056  (((
2057 2057  (% _msthash="903331" _msttexthash="395109" _mstvisible="4" %)
2058 -(% _mstvisible="6" style="color:#4f81bd" %)** **(% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
2046 +(% _mstvisible="6" style="color:#4f81bd" %)** KR920**(%%): LoRaWAN KR920 band
2059 2059  )))
2060 2060  * (% _mstvisible="3" %)
2061 2061  (((
2062 2062  (% _msthash="903332" _msttexthash="400842" _mstvisible="4" %)
2063 -(% _mstvisible="6" style="color:#4f81bd" %)** **(% style="color:red" %)**US915**(%%): LoRaWAN US915 band
2051 +(% _mstvisible="6" style="color:#4f81bd" %)** US915**(%%): LoRaWAN US915 band
2064 2064  )))
2065 2065  * (% _mstvisible="3" %)
2066 2066  (((
2067 2067  (% _msthash="903333" _msttexthash="396487" _mstvisible="4" %)
2068 -(% _mstvisible="6" style="color:#4f81bd" %)** **(% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
2056 +(% _mstvisible="6" style="color:#4f81bd" %)** IN865**(%%): LoRaWAN IN865 band
2069 2069  )))
2070 2070  * (% _mstvisible="3" %)
2071 2071  (((
2072 2072  (% _msthash="903334" _msttexthash="390923" _mstvisible="4" %)
2073 -(% _mstvisible="6" style="color:#4f81bd" %)** **(% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
2061 +(% _mstvisible="6" style="color:#4f81bd" %)** CN470**(%%): LoRaWAN CN470 band
2074 2074  )))
2075 2075  
2076 2076  (% _mstvisible="1" %)
... ... @@ -2083,7 +2083,7 @@
2083 2083  * (% _mstvisible="3" %)
2084 2084  (((
2085 2085  (% _msthash="903335" _msttexthash="720135" _mstvisible="4" %)
2086 -(% style="color:red" %)**E3**(%%): External Temperature Probe
2074 +(% _mstvisible="6" style="color:#4f81bd" %)**E3**(%%): External Temperature Probe
2087 2087  
2088 2088  
2089 2089  (% _msthash="903335" _msttexthash="720135" _mstvisible="4" %)
... ... @@ -2149,6 +2149,8 @@
2149 2149  
2150 2150  * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/home/Products_Public_Document/LoRaWAN%20End%20Node/LHT65N%20Temperature%20%26%20Humidity%20Sensor||_msthash="504975" _msttexthash="51420512"]]
2151 2151  
2140 +
2141 +
2152 2152  = (% _msthash="216320" _msttexthash="10002096" %)10. (%%)FCC Warning =
2153 2153  
2154 2154  (% _mstvisible="1" %)