Last modified by Mengting Qiu on 2025/07/03 14:48

From version 147.19
edited by Xiaoling
on 2022/06/17 14:59
Change comment: There is no comment for this version
To version 147.14
edited by Xiaoling
on 2022/06/17 14:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -413,8 +413,6 @@
413 413  (% _mstvisible="1" %)
414 414  * Temperature:  (0xF5C6-65536)/100=-26.18℃
415 415  
416 -
417 -
418 418  (% _mstvisible="1" %)
419 419  === (% _msthash="475891" _msttexthash="445120" _mstvisible="3" %)2.4.4 Built-in Humidity(%%) ===
420 420  
... ... @@ -591,8 +591,6 @@
591 591  * Sync time OK: 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server.
592 592  * Unix Time Request:1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this)
593 593  
594 -
595 -
596 596  (% _mstvisible="1" %)
597 597  == (% _msthash="487097" _msttexthash="454818" _mstvisible="3" %)2.5 Show data on Datacake(%%) ==
598 598  
... ... @@ -655,8 +655,6 @@
655 655  1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range.
656 656  1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover.
657 657  
658 -
659 -
660 660  (% _mstvisible="1" %)
661 661  === (% _msthash="369915" _msttexthash="342797" _mstvisible="3" %)2.6.2 Unix TimeStamp(%%) ===
662 662  
... ... @@ -1086,19 +1086,19 @@
1086 1086  (% _mstvisible="1" class="box infomessage" %)
1087 1087  (((
1088 1088  (% _msthash="506086" _msttexthash="2193529" _mstvisible="2" style="text-align: left;" %)
1089 -(% _istranslated="1" _mstmutation="1" _mstvisible="4" %)**AT+WMOD=1**(%%):  Enable/disable alarm mode. (0: Disabled, 1: Enabled)
1083 +(% _istranslated="1" _mstmutation="1" _mstvisible="4" %)**AT+WMOD=1**(%%): Enable/disable alarm mode. (0: Disabled, 1: Enabled)
1090 1090  
1091 1091  (% _msthash="506087" _msttexthash="3671265" _mstvisible="2" style="text-align: left;" %)
1092 -(% _istranslated="1" _mstvisible="4" %)**AT+CITEMP=1**(%%):  The interval between checking the alarm temperature. (In minutes)
1086 +(% _istranslated="1" _mstvisible="4" %)**AT+CITEMP=1**(%%): The interval between checking the alarm temperature. (In minutes)
1093 1093  
1094 1094  (% _msthash="506088" _msttexthash="3310437" _mstvisible="2" style="text-align: left;" %)
1095 -(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP**(%%):  Gets or sets the alarm range of the internal temperature sensor
1089 +(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP**(%%): Gets or sets the alarm range of the internal temperature sensor
1096 1096  
1097 1097  (% _mstvisible="2" style="text-align: left;" %)
1098 -(% _istranslated="1" _mstmutation="1" %)**AT+ARTEMP=? **(%%):  Gets the alarm range of the internal temperature sensor(% _mstvisible="3" style="display:none" %)
1092 +(% _istranslated="1" _mstmutation="1" %)**AT+ARTEMP=? **(%%): Gets the alarm range of the internal temperature sensor(% _mstvisible="3" style="display:none" %)
1099 1099  
1100 1100  (% _msthash="506089" _msttexthash="3590067" _mstvisible="2" style="text-align: left;" %)
1101 -(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP=45,105**(%%):  Set the internal temperature sensor alarm range from 45 to 105.
1095 +(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP=45,105**(%%): Set the internal temperature sensor alarm range from 45 to 105.
1102 1102  )))
1103 1103  
1104 1104  
... ... @@ -1141,6 +1141,9 @@
1141 1141  For each success downlink, the PURPLE LED will blink once
1142 1142  
1143 1143  
1138 +
1139 +
1140 +(% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %)
1144 1144  
1145 1145  )))
1146 1146