Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2025/07/03 14:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,6 +22,9 @@ 22 22 (% _mstvisible="1" %) 23 23 ((( 24 24 (% _msthash="506051" _msttexthash="24333127" _mstvisible="2" %) 25 + 26 + 27 +(% _msthash="506051" _msttexthash="24333127" _mstvisible="2" %) 25 25 The Dragino LHT65N Temperature & Humidity sensor is a Long Range LoRaWAN Sensor. It includes a (% _mstvisible="4" style="color:#4f81bd" %)**built-in Temperature & Humidity sensor**(%%) and has an external sensor connector to connect to an external (% _mstvisible="4" style="color:#4f81bd" %)**Temperature Sensor**(% _mstvisible="3" %)**.** 26 26 ))) 27 27 ... ... @@ -74,6 +74,9 @@ 74 74 * Tri-color LED to indicate working status 75 75 * Datalog feature 76 76 80 + 81 + 82 + 77 77 (% _mstvisible="1" %) 78 78 == (% _msthash="323570" _msttexthash="297635" _mstvisible="3" %)1.3 Specification(%%) == 79 79 ... ... @@ -202,8 +202,8 @@ 202 202 The LHT65N has two working modes: 203 203 204 204 (% _mstvisible="1" %) 205 -* **Deep Sleep Mode**: LHT65N doesn’t have any LoRaWAN activation. This mode is used for storage and shipping to save battery life. 206 -* **Working Mode**: In this mode, LHT65N works as LoRaWAN Sensor mode to Join LoRaWAN network and send out the sensor data to the server. Between each sampling/tx/rx periodically, LHT65 will be in STOP mode (IDLE mode), in STOP mode, LHT65N has the same power consumption as Deep Sleep mode. 211 +* (% style="color:blue" %)**Deep Sleep Mode**(%%): LHT65N doesn’t have any LoRaWAN activation. This mode is used for storage and shipping to save battery life. 212 +* (% style="color:blue" %)**Working Mode**(%%): In this mode, LHT65N works as LoRaWAN Sensor mode to Join LoRaWAN network and send out the sensor data to the server. Between each sampling/tx/rx periodically, LHT65N will be in STOP mode (IDLE mode), in STOP mode, LHT65N has the same power consumption as Deep Sleep mode. 207 207 208 208 (% _mstvisible="1" %) 209 209 ((( ... ... @@ -241,7 +241,7 @@ 241 241 Each LHT65N is shipped with a sticker with its device EUI, APP Key and APP EUI as below: 242 242 243 243 (% _mstvisible="1" %) 244 -[[image:image-202205 22232812-2.png||_mstalt="428467" _mstvisible="3" height="219" width="279"]]250 +[[image:image-20220617150003-1.jpeg]] 245 245 246 246 (% _msthash="315244" _msttexthash="3659149" _mstvisible="1" %) 247 247 User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot: ... ... @@ -362,6 +362,9 @@ 362 362 * The 7th byte (EXT #): defines the external sensor model. 363 363 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won’t be these four bytes.) 364 364 371 + 372 + 373 + 365 365 (% _mstvisible="1" %) 366 366 === (% _msthash="360269" _msttexthash="333762" _mstvisible="3" %)2.4.1 Decoder in TTN V3(%%) === 367 367 ... ... @@ -398,6 +398,9 @@ 398 398 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 399 399 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 400 400 410 + 411 + 412 + 401 401 (% _mstvisible="1" %) 402 402 === (% _msthash="600769" _msttexthash="565838" _mstvisible="3" %)2.4.3 Built-in Temperature(%%) === 403 403 ... ... @@ -413,6 +413,9 @@ 413 413 (% _mstvisible="1" %) 414 414 * Temperature: (0xF5C6-65536)/100=-26.18℃ 415 415 428 + 429 + 430 + 416 416 (% _mstvisible="1" %) 417 417 === (% _msthash="475891" _msttexthash="445120" _mstvisible="3" %)2.4.4 Built-in Humidity(%%) === 418 418 ... ... @@ -422,6 +422,9 @@ 422 422 (% _mstvisible="1" %) 423 423 * Humidity: 0x025C/10=60.4% 424 424 440 + 441 + 442 + 425 425 (% _mstvisible="1" %) 426 426 === (% _msthash="116532" _msttexthash="87958" _mstvisible="3" %)2.4.5 Ext #(%%) === 427 427 ... ... @@ -589,6 +589,9 @@ 589 589 * Sync time OK: 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 590 590 * Unix Time Request:1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 591 591 610 + 611 + 612 + 592 592 (% _mstvisible="1" %) 593 593 == (% _msthash="487097" _msttexthash="454818" _mstvisible="3" %)2.5 Show data on Datacake(%%) == 594 594 ... ... @@ -653,6 +653,7 @@ 653 653 654 654 655 655 677 + 656 656 (% _mstvisible="1" %) 657 657 === (% _msthash="369915" _msttexthash="342797" _mstvisible="3" %)2.6.2 Unix TimeStamp(%%) === 658 658 ... ... @@ -1168,8 +1168,6 @@ 1168 1168 * -55°C to 125°C 1169 1169 * Working voltage 2.35v ~~ 5v 1170 1170 1171 - 1172 - 1173 1173 (% _mstvisible="1" style="text-align: left;" %) 1174 1174 = (% _msthash="1940107" _msttexthash="1714063" _mstvisible="3" %)4. Configure LHT65N via AT command or LoRaWAN downlink(%%) = 1175 1175 ... ... @@ -1385,8 +1385,6 @@ 1385 1385 * 0xA800 **~-~->** AT+PID=0 1386 1386 * 0xA801 **~-~->** AT+PID=1 1387 1387 1388 - 1389 - 1390 1390 (% _mstvisible="1" style="text-align: left;" %) 1391 1391 == (% _msthash="266344" _msttexthash="242879" _mstvisible="3" %)4.4 Set Password(%%) == 1392 1392 ... ... @@ -1458,8 +1458,6 @@ 1458 1458 (% _mstvisible="1" %) 1459 1459 * There is no downlink command to set to Sleep mode. 1460 1460 1461 - 1462 - 1463 1463 (% _mstvisible="1" %) 1464 1464 == (% _msthash="336557" _msttexthash="309712" _mstvisible="3" %)4.7 Set system time(%%) == 1465 1465 ... ... @@ -1594,8 +1594,6 @@ 1594 1594 (% _mstvisible="1" %) 1595 1595 * Example: 0xA301 ~/~/Same as AT+CLRDTA 1596 1596 1597 - 1598 - 1599 1599 (% _mstvisible="1" %) 1600 1600 == (% _msthash="740532" _msttexthash="701363" _mstvisible="3" %)4.13 Auto Send None-ACK messages(%%) == 1601 1601 ... ... @@ -1619,8 +1619,6 @@ 1619 1619 (% _mstvisible="1" %) 1620 1620 * Example: 0x3401 ~/~/Same as AT+PNACKMD=1 1621 1621 1622 - 1623 - 1624 1624 (% _mstvisible="1" %) 1625 1625 = (% _msthash="568737" _msttexthash="502827" _mstvisible="3" %)5. Battery & How to replace(%%) = 1626 1626 ... ... @@ -2110,11 +2110,6 @@ 2110 2110 ))) 2111 2111 * (% _mstvisible="3" %) 2112 2112 ((( 2113 -(% _msthash="903337" _msttexthash="242567" _mstvisible="4" %) 2114 -Program cable x 1 2115 -))) 2116 -* (% _mstvisible="3" %) 2117 -((( 2118 2118 (% _msthash="903338" _msttexthash="544167" _mstvisible="4" %) 2119 2119 Optional external sensor 2120 2120 ))) ... ... @@ -2149,6 +2149,8 @@ 2149 2149 2150 2150 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/home/Products_Public_Document/LoRaWAN%20End%20Node/LHT65N%20Temperature%20%26%20Humidity%20Sensor||_msthash="504975" _msttexthash="51420512"]] 2151 2151 2159 + 2160 + 2152 2152 = (% _msthash="216320" _msttexthash="10002096" %)10. (%%)FCC Warning = 2153 2153 2154 2154 (% _mstvisible="1" %)
- image-20220617150003-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.5 KB - Content