Last modified by Mengting Qiu on 2025/07/03 14:48

From version 147.17
edited by Xiaoling
on 2022/06/17 14:58
Change comment: There is no comment for this version
To version 147.5
edited by Xiaoling
on 2022/06/17 14:46
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -651,8 +651,6 @@
651 651  1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range.
652 652  1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover.
653 653  
654 -
655 -
656 656  (% _mstvisible="1" %)
657 657  === (% _msthash="369915" _msttexthash="342797" _mstvisible="3" %)2.6.2 Unix TimeStamp(%%) ===
658 658  
... ... @@ -1082,19 +1082,19 @@
1082 1082  (% _mstvisible="1" class="box infomessage" %)
1083 1083  (((
1084 1084  (% _msthash="506086" _msttexthash="2193529" _mstvisible="2" style="text-align: left;" %)
1085 -(% _istranslated="1" _mstmutation="1" _mstvisible="4" %)**AT+WMOD=1**(%%):  Enable/disable alarm mode. (0: Disabled, 1: Enabled)
1083 +(% _istranslated="1" _mstmutation="1" _mstvisible="4" %)**AT+WMOD=1**(%%): Enable/disable alarm mode. (0: Disabled, 1: Enabled)
1086 1086  
1087 1087  (% _msthash="506087" _msttexthash="3671265" _mstvisible="2" style="text-align: left;" %)
1088 -(% _istranslated="1" _mstvisible="4" %)**AT+CITEMP=1**(%%):  The interval between checking the alarm temperature. (In minutes)
1086 +(% _istranslated="1" _mstvisible="4" %)**AT+CITEMP=1**(%%): The interval between checking the alarm temperature. (In minutes)
1089 1089  
1090 1090  (% _msthash="506088" _msttexthash="3310437" _mstvisible="2" style="text-align: left;" %)
1091 -(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP**(%%):  Gets or sets the alarm range of the internal temperature sensor
1089 +(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP**(%%): Gets or sets the alarm range of the internal temperature sensor
1092 1092  
1093 1093  (% _mstvisible="2" style="text-align: left;" %)
1094 -(% _istranslated="1" _mstmutation="1" %)**AT+ARTEMP=? **(%%):  Gets the alarm range of the internal temperature sensor(% _mstvisible="3" style="display:none" %)
1092 +(% _istranslated="1" _mstmutation="1" %)**AT+ARTEMP=? **(%%): Gets the alarm range of the internal temperature sensor(% _mstvisible="3" style="display:none" %)
1095 1095  
1096 1096  (% _msthash="506089" _msttexthash="3590067" _mstvisible="2" style="text-align: left;" %)
1097 -(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP=45,105**(%%):  Set the internal temperature sensor alarm range from 45 to 105.
1095 +(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP=45,105**(%%): Set the internal temperature sensor alarm range from 45 to 105.
1098 1098  )))
1099 1099  
1100 1100  
... ... @@ -1137,6 +1137,9 @@
1137 1137  For each success downlink, the PURPLE LED will blink once
1138 1138  
1139 1139  
1138 +
1139 +
1140 +(% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %)
1140 1140  
1141 1141  )))
1142 1142  
... ... @@ -1168,8 +1168,6 @@
1168 1168  * -55°C to 125°C
1169 1169  * Working voltage 2.35v ~~ 5v
1170 1170  
1171 -
1172 -
1173 1173  (% _mstvisible="1" style="text-align: left;" %)
1174 1174  = (% _msthash="1940107" _msttexthash="1714063" _mstvisible="3" %)4. Configure LHT65N via AT command or LoRaWAN downlink(%%) =
1175 1175  
... ... @@ -1242,7 +1242,7 @@
1242 1242  (% _mstvisible="1" %)
1243 1243  (((
1244 1244  (% _mstvisible="2" style="text-align: left;" %)
1245 -(% _mstvisible="3" style="color:#4f81bd" %)* (% _msthash="506249" _mstmutation="1" _msttexthash="317850" _mstvisible="4" style="color:#4f81bd" %)**Commands special design for LHT65N**
1244 +(% _mstvisible="3" style="color:#4f81bd" %)* (% _msthash="506054" _msttexthash="792038" %)**Commands special design for LHT65N**
1246 1246  )))
1247 1247  
1248 1248  (% _mstvisible="1" %)
... ... @@ -1385,8 +1385,6 @@
1385 1385  * 0xA800  **~-~->** AT+PID=0
1386 1386  * 0xA801     **~-~->** AT+PID=1
1387 1387  
1388 -
1389 -
1390 1390  (% _mstvisible="1" style="text-align: left;" %)
1391 1391  == (% _msthash="266344" _msttexthash="242879" _mstvisible="3" %)4.4 Set Password(%%) ==
1392 1392  
... ... @@ -1458,8 +1458,6 @@
1458 1458  (% _mstvisible="1" %)
1459 1459  * There is no downlink command to set to Sleep mode.
1460 1460  
1461 -
1462 -
1463 1463  (% _mstvisible="1" %)
1464 1464  == (% _msthash="336557" _msttexthash="309712" _mstvisible="3" %)4.7 Set system time(%%) ==
1465 1465  
... ... @@ -1594,8 +1594,6 @@
1594 1594  (% _mstvisible="1" %)
1595 1595  * Example: 0xA301 ~/~/Same as AT+CLRDTA
1596 1596  
1597 -
1598 -
1599 1599  (% _mstvisible="1" %)
1600 1600  == (% _msthash="740532" _msttexthash="701363" _mstvisible="3" %)4.13 Auto Send None-ACK messages(%%) ==
1601 1601  
... ... @@ -1619,8 +1619,6 @@
1619 1619  (% _mstvisible="1" %)
1620 1620  * Example: 0x3401 ~/~/Same as AT+PNACKMD=1
1621 1621  
1622 -
1623 -
1624 1624  (% _mstvisible="1" %)
1625 1625  = (% _msthash="568737" _msttexthash="502827" _mstvisible="3" %)5. Battery & How to replace(%%) =
1626 1626  
... ... @@ -1703,7 +1703,7 @@
1703 1703  
1704 1704  (((
1705 1705  (% _msthash="736726" _msttexthash="67213055" %)
1706 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**) (%%)to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
1697 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.htmlml]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**) (%%)to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
1707 1707  )))
1708 1708  
1709 1709  (((
... ... @@ -1957,21 +1957,23 @@
1957 1957  
1958 1958  [[image:image-20220615153355-1.png]]
1959 1959  
1960 -(% style="background-color:yellow" %)**1 < - -> GND  < - ->  Black**
1951 +(% _msthash="506138" _msttexthash="243997" %)
1952 +* (% style="background-color:yellow" %)1 < - -> GND  < - ->  Black
1961 1961  
1962 -(% style="background-color:yellow" %)**5 < - ->  RXD  < - ->  White**
1954 +(% _msthash="506139" _msttexthash="257166" %)
1955 +* (% style="background-color:yellow" %)5 < - ->  RXD  < - ->  White
1963 1963  
1964 -(% style="background-color:yellow" %)**9 < - ->  TXD  < - ->  Green**
1957 +(% _msthash="506140" _msttexthash="253799" %)
1958 +* (% style="background-color:yellow" %)9 < - ->  TXD  < - ->  Green
1965 1965  
1966 1966  [[image:image-20220615153914-2.jpeg||height="608" width="456"]]
1967 1967  
1968 -
1969 1969  (((
1970 1970  (% _msthash="736728" _msttexthash="67213055" %)
1971 -(((
1972 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:red" %)**123456**)(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
1964 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.htmlml]], SecureCRT) baud rate to
1965 +(% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:
1966 +(% style="color:red" %)**123456**)(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
1973 1973  )))
1974 -)))
1975 1975  
1976 1976  (((
1977 1977  (% _msthash="736729" _msttexthash="1907009" %)
... ... @@ -1983,15 +1983,22 @@
1983 1983  )))
1984 1984  
1985 1985  
1979 +
1986 1986  == 6.5 How to use TTL-USB to connect PC to upgrade firmware? ==
1987 1987  
1988 1988  [[image:image-20220615153355-1.png]]
1989 1989  
1990 -(% style="background-color:yellow" %)**4  < - ->  3.3V  < - ->  Blue**
1984 +(% _msthash="506141" _msttexthash="231309" %)
1985 +*
1986 +** (% style="background-color:yellow" %)4  < - ->  3.3V  < - ->  Blue
1991 1991  
1992 -(% style="background-color:yellow" %)**5 < - ->  RXD  < - ->  White**
1988 +(% _msthash="506142" _msttexthash="257166" %)
1989 +*
1990 +** (% style="background-color:yellow" %)5 < - ->  RXD  < - ->  White
1993 1993  
1994 -(% style="background-color:yellow" %)**9 < - ->  TXD  < - ->  Green**
1992 +(% _msthash="506143" _msttexthash="253799" %)
1993 +*
1994 +** (% style="background-color:yellow" %)9 < - ->  TXD  < - ->  Green
1995 1995  
1996 1996  Use after connection, ground wire(1 < - -> GND  < - ->  Black) for 1s and then pull it out.Then restart the device.
1997 1997  
... ... @@ -2011,7 +2011,7 @@
2011 2011  [[image:image-20220615171334-6.png]]
2012 2012  
2013 2013  
2014 -(% _istranslated="1" _mstmutation="1" %)**Step4:**(%%)Click Start
2014 +(% _istranslated="1" _mstmutation="1" %)**Step4:**(%%)Click Start
2015 2015  
2016 2016  
2017 2017  )))