Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2025/07/03 14:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1080,19 +1080,19 @@ 1080 1080 (% _mstvisible="1" class="box infomessage" %) 1081 1081 ((( 1082 1082 (% _msthash="506086" _msttexthash="2193529" _mstvisible="2" style="text-align: left;" %) 1083 -(% _istranslated="1" _mstmutation="1" _mstvisible="4" %)**AT+WMOD=1**(%%): 1083 +(% _istranslated="1" _mstmutation="1" _mstvisible="4" %)**AT+WMOD=1**(%%): Enable/disable alarm mode. (0: Disabled, 1: Enabled) 1084 1084 1085 1085 (% _msthash="506087" _msttexthash="3671265" _mstvisible="2" style="text-align: left;" %) 1086 -(% _istranslated="1" _mstvisible="4" %)**AT+CITEMP=1**(%%): 1086 +(% _istranslated="1" _mstvisible="4" %)**AT+CITEMP=1**(%%): The interval between checking the alarm temperature. (In minutes) 1087 1087 1088 1088 (% _msthash="506088" _msttexthash="3310437" _mstvisible="2" style="text-align: left;" %) 1089 -(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP**(%%): 1089 +(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP**(%%): Gets or sets the alarm range of the internal temperature sensor 1090 1090 1091 1091 (% _mstvisible="2" style="text-align: left;" %) 1092 -(% _istranslated="1" _mstmutation="1" %)**AT+ARTEMP=? **(%%): 1092 +(% _istranslated="1" _mstmutation="1" %)**AT+ARTEMP=? **(%%): Gets the alarm range of the internal temperature sensor(% _mstvisible="3" style="display:none" %) 1093 1093 1094 1094 (% _msthash="506089" _msttexthash="3590067" _mstvisible="2" style="text-align: left;" %) 1095 -(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP=45,105**(%%): 1095 +(% _istranslated="1" _mstvisible="4" %)**AT+ARTEMP=45,105**(%%): Set the internal temperature sensor alarm range from 45 to 105. 1096 1096 ))) 1097 1097 1098 1098 ... ... @@ -1135,6 +1135,9 @@ 1135 1135 For each success downlink, the PURPLE LED will blink once 1136 1136 1137 1137 1138 + 1139 + 1140 +(% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %) 1138 1138 1139 1139 ))) 1140 1140 ... ... @@ -1166,8 +1166,6 @@ 1166 1166 * -55°C to 125°C 1167 1167 * Working voltage 2.35v ~~ 5v 1168 1168 1169 - 1170 - 1171 1171 (% _mstvisible="1" style="text-align: left;" %) 1172 1172 = (% _msthash="1940107" _msttexthash="1714063" _mstvisible="3" %)4. Configure LHT65N via AT command or LoRaWAN downlink(%%) = 1173 1173 ... ... @@ -1240,7 +1240,7 @@ 1240 1240 (% _mstvisible="1" %) 1241 1241 ((( 1242 1242 (% _mstvisible="2" style="text-align: left;" %) 1243 -(% _mstvisible="3" style="color:#4f81bd" %)* (% _msthash="506 249" _mstmutation="1" _msttexthash="317850" _mstvisible="4" style="color:#4f81bd" %)**Commands special design for LHT65N**1244 +(% _mstvisible="3" style="color:#4f81bd" %)* (% _msthash="506054" _msttexthash="792038" %)**Commands special design for LHT65N** 1244 1244 ))) 1245 1245 1246 1246 (% _mstvisible="1" %) ... ... @@ -1383,8 +1383,6 @@ 1383 1383 * 0xA800 **~-~->** AT+PID=0 1384 1384 * 0xA801 **~-~->** AT+PID=1 1385 1385 1386 - 1387 - 1388 1388 (% _mstvisible="1" style="text-align: left;" %) 1389 1389 == (% _msthash="266344" _msttexthash="242879" _mstvisible="3" %)4.4 Set Password(%%) == 1390 1390 ... ... @@ -1456,8 +1456,6 @@ 1456 1456 (% _mstvisible="1" %) 1457 1457 * There is no downlink command to set to Sleep mode. 1458 1458 1459 - 1460 - 1461 1461 (% _mstvisible="1" %) 1462 1462 == (% _msthash="336557" _msttexthash="309712" _mstvisible="3" %)4.7 Set system time(%%) == 1463 1463