Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -659,6 +659,10 @@ 659 659 1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range. 660 660 1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover. 661 661 662 + 663 + 664 + 665 + 662 662 (% _mstvisible="1" %) 663 663 === (% _msthash="369915" _msttexthash="342797" _mstvisible="3" %)2.6.2 Unix TimeStamp(%%) === 664 664 ... ... @@ -1134,6 +1134,12 @@ 1134 1134 ((( 1135 1135 (% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %) 1136 1136 For each success downlink, the PURPLE LED will blink once 1141 + 1142 + 1143 + 1144 + 1145 +(% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %) 1146 + 1137 1137 ))) 1138 1138 1139 1139 (% _mstvisible="1" style="text-align: left;" %) ... ... @@ -1164,6 +1164,10 @@ 1164 1164 * -55°C to 125°C 1165 1165 * Working voltage 2.35v ~~ 5v 1166 1166 1177 + 1178 + 1179 + 1180 + 1167 1167 (% _mstvisible="1" style="text-align: left;" %) 1168 1168 = (% _msthash="1940107" _msttexthash="1714063" _mstvisible="3" %)4. Configure LHT65N via AT command or LoRaWAN downlink(%%) = 1169 1169 ... ... @@ -1244,6 +1244,7 @@ 1244 1244 (% _msthash="506254" _msttexthash="1501357" _mstvisible="2" style="text-align: left;" %) 1245 1245 These commands are only valid for LHT65N, as below: 1246 1246 1261 + 1247 1247 (% _msthash="506254" _msttexthash="1501357" _mstvisible="2" style="text-align: left;" %) 1248 1248 1249 1249 ))) ... ... @@ -1378,6 +1378,10 @@ 1378 1378 * 0xA800 **~-~->** AT+PID=0 1379 1379 * 0xA801 **~-~->** AT+PID=1 1380 1380 1396 + 1397 + 1398 + 1399 + 1381 1381 (% _mstvisible="1" style="text-align: left;" %) 1382 1382 == (% _msthash="266344" _msttexthash="242879" _mstvisible="3" %)4.4 Set Password(%%) == 1383 1383 ... ... @@ -1447,6 +1447,10 @@ 1447 1447 (% _mstvisible="1" %) 1448 1448 * There is no downlink command to set to Sleep mode. 1449 1449 1469 + 1470 + 1471 + 1472 + 1450 1450 (% _mstvisible="1" %) 1451 1451 == (% _msthash="336557" _msttexthash="309712" _mstvisible="3" %)4.7 Set system time(%%) == 1452 1452 ... ... @@ -1581,6 +1581,10 @@ 1581 1581 (% _mstvisible="1" %) 1582 1582 * Example: 0xA301 ~/~/Same as AT+CLRDTA 1583 1583 1607 + 1608 + 1609 + 1610 + 1584 1584 (% _mstvisible="1" %) 1585 1585 == (% _msthash="740532" _msttexthash="701363" _mstvisible="3" %)4.13 Auto Send None-ACK messages(%%) == 1586 1586 ... ... @@ -1604,6 +1604,10 @@ 1604 1604 (% _mstvisible="1" %) 1605 1605 * Example: 0x3401 ~/~/Same as AT+PNACKMD=1 1606 1606 1634 + 1635 + 1636 + 1637 + 1607 1607 (% _mstvisible="1" %) 1608 1608 = (% _msthash="568737" _msttexthash="502827" _mstvisible="3" %)5. Battery & How to replace(%%) = 1609 1609 ... ... @@ -1695,43 +1695,43 @@ 1695 1695 1696 1696 AT+<CMD>? : Help on <CMD> 1697 1697 1698 -AT+<CMD> : Run <CMD> 1729 +AT+<CMD> : Run <CMD> 1699 1699 1700 -AT+<CMD>=<value> : Set the value 1731 +AT+<CMD>=<value> : Set the value 1701 1701 1702 -AT+<CMD>=? : Get the value 1733 +AT+<CMD>=? : Get the value 1703 1703 1704 -AT+DEBUG:Set more info output 1735 +AT+DEBUG: Set more info output 1705 1705 1706 -ATZ: Trig a reset of the MCU 1737 +ATZ: Trig a reset of the MCU 1707 1707 1708 -AT+FDR: Reset Parameters to Factory Default, Keys Reserve 1739 +AT+FDR: Reset Parameters to Factory Default, Keys Reserve 1709 1709 1710 -AT+DEUI: Get or Set the Device EUI 1741 +AT+DEUI: Get or Set the Device EUI 1711 1711 1712 -AT+DADDR: Get or Set the Device Address 1743 +AT+DADDR: Get or Set the Device Address 1713 1713 1714 -AT+APPKEY: Get or Set the Application Key 1745 +AT+APPKEY: Get or Set the Application Key 1715 1715 1716 -AT+NWKSKEY: Get or Set the Network Session Key 1747 +AT+NWKSKEY: Get or Set the Network Session Key 1717 1717 1718 -AT+APPSKEY: Get or Set the Application Session Key 1749 +AT+APPSKEY: Get or Set the Application Session Key 1719 1719 1720 -AT+APPEUI: Get or Set the Application EUI 1751 +AT+APPEUI: Get or Set the Application EUI 1721 1721 1722 -AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 1753 +AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 1723 1723 1724 -AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 1755 +AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 1725 1725 1726 -AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1757 +AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1727 1727 1728 -AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 1759 +AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 1729 1729 1730 -AT+PNM: Get or Set the public network mode. (0: off, 1: on) 1761 +AT+PNM: Get or Set the public network mode. (0: off, 1: on) 1731 1731 1732 -AT+RX2FQ: Get or Set the Rx2 window frequency 1763 +AT+RX2FQ: Get or Set the Rx2 window frequency 1733 1733 1734 -AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 1765 +AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 1735 1735 1736 1736 AT+RX1DL: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 1737 1737