Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2025/07/03 14:48
From version 123.2
edited by Xiaoling
on 2022/06/13 16:20
on 2022/06/13 16:20
Change comment:
There is no comment for this version
To version 133.1
edited by Bei Jinggeng
on 2022/06/15 11:46
on 2022/06/15 11:46
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -74,7 +74,6 @@ 74 74 * Tri-color LED to indicate working status 75 75 * Datalog feature 76 76 77 - 78 78 (% _mstvisible="1" %) 79 79 == (% _msthash="323570" _msttexthash="297635" _mstvisible="3" %)1.3 Specification(%%) == 80 80 ... ... @@ -363,7 +363,6 @@ 363 363 * The 7th byte (EXT #): defines the external sensor model. 364 364 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won’t be these four bytes.) 365 365 366 - 367 367 (% _mstvisible="1" %) 368 368 === (% _msthash="360269" _msttexthash="333762" _mstvisible="3" %)2.4.1 Decoder in TTN V3(%%) === 369 369 ... ... @@ -400,7 +400,6 @@ 400 400 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 401 401 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 402 402 403 - 404 404 (% _mstvisible="1" %) 405 405 === (% _msthash="600769" _msttexthash="565838" _mstvisible="3" %)2.4.3 Built-in Temperature(%%) === 406 406 ... ... @@ -416,7 +416,6 @@ 416 416 (% _mstvisible="1" %) 417 417 * Temperature: (0xF5C6-65536)/100=-26.18℃ 418 418 419 - 420 420 (% _mstvisible="1" %) 421 421 === (% _msthash="475891" _msttexthash="445120" _mstvisible="3" %)2.4.4 Built-in Humidity(%%) === 422 422 ... ... @@ -426,7 +426,6 @@ 426 426 (% _mstvisible="1" %) 427 427 * Humidity: 0x025C/10=60.4% 428 428 429 - 430 430 (% _mstvisible="1" %) 431 431 === (% _msthash="116532" _msttexthash="87958" _mstvisible="3" %)2.4.5 Ext #(%%) === 432 432 ... ... @@ -594,6 +594,7 @@ 594 594 * Sync time OK: 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 595 595 * Unix Time Request:1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 596 596 592 + 597 597 (% _mstvisible="1" %) 598 598 == (% _msthash="487097" _msttexthash="454818" _mstvisible="3" %)2.5 Show data on Datacake(%%) == 599 599 ... ... @@ -656,6 +656,8 @@ 656 656 1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range. 657 657 1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover. 658 658 655 + 656 + 659 659 (% _mstvisible="1" %) 660 660 === (% _msthash="369915" _msttexthash="342797" _mstvisible="3" %)2.6.2 Unix TimeStamp(%%) === 661 661 ... ... @@ -1131,6 +1131,12 @@ 1131 1131 ((( 1132 1132 (% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %) 1133 1133 For each success downlink, the PURPLE LED will blink once 1132 + 1133 + 1134 + 1135 + 1136 +(% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %) 1137 + 1134 1134 ))) 1135 1135 1136 1136 (% _mstvisible="1" style="text-align: left;" %) ... ... @@ -1161,6 +1161,8 @@ 1161 1161 * -55°C to 125°C 1162 1162 * Working voltage 2.35v ~~ 5v 1163 1163 1168 + 1169 + 1164 1164 (% _mstvisible="1" style="text-align: left;" %) 1165 1165 = (% _msthash="1940107" _msttexthash="1714063" _mstvisible="3" %)4. Configure LHT65N via AT command or LoRaWAN downlink(%%) = 1166 1166 ... ... @@ -1241,6 +1241,7 @@ 1241 1241 (% _msthash="506254" _msttexthash="1501357" _mstvisible="2" style="text-align: left;" %) 1242 1242 These commands are only valid for LHT65N, as below: 1243 1243 1250 + 1244 1244 (% _msthash="506254" _msttexthash="1501357" _mstvisible="2" style="text-align: left;" %) 1245 1245 1246 1246 ))) ... ... @@ -1375,6 +1375,8 @@ 1375 1375 * 0xA800 **~-~->** AT+PID=0 1376 1376 * 0xA801 **~-~->** AT+PID=1 1377 1377 1385 + 1386 + 1378 1378 (% _mstvisible="1" style="text-align: left;" %) 1379 1379 == (% _msthash="266344" _msttexthash="242879" _mstvisible="3" %)4.4 Set Password(%%) == 1380 1380 ... ... @@ -1444,6 +1444,8 @@ 1444 1444 (% _mstvisible="1" %) 1445 1445 * There is no downlink command to set to Sleep mode. 1446 1446 1456 + 1457 + 1447 1447 (% _mstvisible="1" %) 1448 1448 == (% _msthash="336557" _msttexthash="309712" _mstvisible="3" %)4.7 Set system time(%%) == 1449 1449 ... ... @@ -1578,6 +1578,8 @@ 1578 1578 (% _mstvisible="1" %) 1579 1579 * Example: 0xA301 ~/~/Same as AT+CLRDTA 1580 1580 1592 + 1593 + 1581 1581 (% _mstvisible="1" %) 1582 1582 == (% _msthash="740532" _msttexthash="701363" _mstvisible="3" %)4.13 Auto Send None-ACK messages(%%) == 1583 1583 ... ... @@ -1601,6 +1601,8 @@ 1601 1601 (% _mstvisible="1" %) 1602 1602 * Example: 0x3401 ~/~/Same as AT+PNACKMD=1 1603 1603 1617 + 1618 + 1604 1604 (% _mstvisible="1" %) 1605 1605 = (% _msthash="568737" _msttexthash="502827" _mstvisible="3" %)5. Battery & How to replace(%%) = 1606 1606 ... ... @@ -1690,135 +1690,164 @@ 1690 1690 1691 1691 AT Command List is as below: 1692 1692 1693 -AT+<CMD>? : Help on <CMD> 1708 +AT+<CMD>? : Help on <CMD> 1694 1694 1695 -AT+<CMD> : Run <CMD> 1710 +AT+<CMD> : Run <CMD> 1696 1696 1697 -AT+<CMD>=<value> : Set the value 1712 +AT+<CMD>=<value> : Set the value 1698 1698 1699 -AT+<CMD>=? : Get the value 1714 +AT+<CMD>=? : Get the value 1700 1700 1701 -AT+DEBUG:Set more info output 1716 +AT+DEBUG: Set more info output 1702 1702 1703 -ATZ: Trig a reset of the MCU 1718 +ATZ: Trig a reset of the MCU 1704 1704 1705 -AT+FDR: Reset Parameters to Factory Default, Keys Reserve 1720 +AT+FDR: Reset Parameters to Factory Default, Keys Reserve 1706 1706 1707 -AT+DEUI: Get or Set the Device EUI 1722 +AT+DEUI: Get or Set the Device EUI 1708 1708 1709 -AT+DADDR: Get or Set the Device Address 1724 +AT+DADDR: Get or Set the Device Address 1710 1710 1711 -AT+APPKEY: Get or Set the Application Key 1726 +AT+APPKEY: Get or Set the Application Key 1712 1712 1713 -AT+NWKSKEY: Get or Set the Network Session Key 1728 +AT+NWKSKEY: Get or Set the Network Session Key 1714 1714 1715 -AT+APPSKEY: Get or Set the Application Session Key 1730 +AT+APPSKEY: Get or Set the Application Session Key 1716 1716 1717 -AT+APPEUI: Get or Set the Application EUI 1732 +AT+APPEUI: Get or Set the Application EUI 1718 1718 1719 -AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 1734 +AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 1720 1720 1721 -AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 1736 +AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 1722 1722 1723 -AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1738 +AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1724 1724 1725 -AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 1740 +AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 1726 1726 1727 -AT+PNM: Get or Set the public network mode. (0: off, 1: on) 1742 +AT+PNM: Get or Set the public network mode. (0: off, 1: on) 1728 1728 1729 -AT+RX2FQ: Get or Set the Rx2 window frequency 1744 +AT+RX2FQ: Get or Set the Rx2 window frequency 1730 1730 1731 -AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 1746 +AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 1732 1732 1733 -AT+RX1DL: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 1748 +AT+RX1DL: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 1734 1734 1735 -AT+RX2DL: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 1750 +AT+RX2DL: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 1736 1736 1737 -AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 1752 +AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 1738 1738 1739 -AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 1754 +AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 1740 1740 1741 -AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 1756 +AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 1742 1742 1743 -AT+NWKID: Get or Set the Network ID 1758 +AT+NWKID: Get or Set the Network ID 1744 1744 1745 -AT+FCU: Get or Set the Frame Counter Uplink 1760 +AT+FCU: Get or Set the Frame Counter Uplink 1746 1746 1747 -AT+FCD: Get or Set the Frame Counter Downlink 1762 +AT+FCD: Get or Set the Frame Counter Downlink 1748 1748 1749 -AT+CLASS: Get or Set the Device Class 1764 +AT+CLASS: Get or Set the Device Class 1750 1750 1751 -AT+JOIN: Join network 1766 +AT+JOIN: Join network 1752 1752 1753 -AT+NJS: Get the join status 1768 +AT+NJS: Get the join status 1754 1754 1755 -AT+SENDB: Send hexadecimal data along with the application port 1770 +AT+SENDB: Send hexadecimal data along with the application port 1756 1756 1757 -AT+SEND: Send text data along with the application port 1772 +AT+SEND: Send text data along with the application port 1758 1758 1759 -AT+RECVB: Print last received data in binary format (with hexadecimal values) 1774 +AT+RECVB: Print last received data in binary format (with hexadecimal values) 1760 1760 1761 -AT+RECV: Print last received data in raw format 1776 +AT+RECV: Print last received data in raw format 1762 1762 1763 -AT+VER: Get current image version and Frequency Band 1778 +AT+VER: Get current image version and Frequency Band 1764 1764 1765 -AT+CFM: Get or Set the confirmation mode (0-1) 1780 +AT+CFM: Get or Set the confirmation mode (0-1) 1766 1766 1767 -AT+CFS: Get confirmation status of the last AT+SEND (0-1) 1782 +AT+CFS: Get confirmation status of the last AT+SEND (0-1) 1768 1768 1769 -AT+SNR: Get the SNR of the last received packet 1784 +AT+SNR: Get the SNR of the last received packet 1770 1770 1771 -AT+RSSI: Get the RSSI of the last received packet 1786 +AT+RSSI: Get the RSSI of the last received packet 1772 1772 1773 -AT+TDC: Get or set the application data transmission interval in ms 1788 +AT+TDC: Get or set the application data transmission interval in ms 1774 1774 1775 -AT+PORT: Get or set the application port 1790 +AT+PORT: Get or set the application port 1776 1776 1777 -AT+DISAT: Disable AT commands 1792 +AT+DISAT: Disable AT commands 1778 1778 1779 -AT+PWORD: Set password, max 9 digits 1794 +AT+PWORD: Set password, max 9 digits 1780 1780 1781 -AT+CHS: Get or Set Frequency (Unit: Hz) for Single Channel Mode 1796 +AT+CHS: Get or Set Frequency (Unit: Hz) for Single Channel Mode 1782 1782 1783 -AT+CHE: Get or Set eight channels mode,Only for US915,AU915,CN470 1798 +AT+CHE: Get or Set eight channels mode,Only for US915,AU915,CN470 1784 1784 1785 -AT+PDTA: Print the sector data from start page to stop page 1800 +AT+PDTA: Print the sector data from start page to stop page 1786 1786 1787 -AT+PLDTA: Print the last few sets of data 1802 +AT+PLDTA: Print the last few sets of data 1788 1788 1789 -AT+CLRDTA: Clear the storage, record position back to 1st 1804 +AT+CLRDTA: Clear the storage, record position back to 1st 1790 1790 1791 -AT+SLEEP: Set sleep mode 1806 +AT+SLEEP: Set sleep mode 1792 1792 1793 -AT+EXT: Get or Set external sensor model 1808 +AT+EXT: Get or Set external sensor model 1794 1794 1795 -AT+BAT: Get the current battery voltage in mV 1810 +AT+BAT: Get the current battery voltage in mV 1796 1796 1797 -AT+CFG: Print all configurations 1812 +AT+CFG: Print all configurations 1798 1798 1799 -AT+WMOD: Get or Set Work Mode 1814 +AT+WMOD: Get or Set Work Mode 1800 1800 1801 -AT+ARTEMP: Get or set the internal Temperature sensor alarm range 1816 +AT+ARTEMP: Get or set the internal Temperature sensor alarm range 1802 1802 1803 -AT+CITEMP: Get or set the internal Temperature sensor collection interval in min 1818 +AT+CITEMP: Get or set the internal Temperature sensor collection interval in min 1804 1804 1805 -AT+SETCNT:Set the count at present 1820 +AT+SETCNT: Set the count at present 1806 1806 1807 -AT+RJTDC: Get or set the ReJoin data transmission interval in min 1822 +AT+RJTDC: Get or set the ReJoin data transmission interval in min 1808 1808 1809 -AT+RPL: Get or set response level 1824 +AT+RPL: Get or set response level 1810 1810 1811 -AT+TIMESTAMP: Get or Set UNIX timestamp in second 1826 +AT+TIMESTAMP: Get or Set UNIX timestamp in second 1812 1812 1813 -AT+LEAPSEC: Get or Set Leap Second 1828 +AT+LEAPSEC: Get or Set Leap Second 1814 1814 1815 -AT+SYNCMOD: Get or Set time synchronization method 1830 +AT+SYNCMOD: Get or Set time synchronization method 1816 1816 1817 -AT+SYNCTDC: Get or set time synchronization interval in day 1832 +AT+SYNCTDC: Get or set time synchronization interval in day 1818 1818 1819 -AT+PID: Get or set the PID 1834 +AT+PID: Get or set the PID 1820 1820 1821 - 1836 + 1837 +== 6.2 Where to use AT commands and Downlink commands == 1838 + 1839 +AT commands: 1840 + 1841 +[[image:image-20220615092034-1.png]] 1842 + 1843 +Downlink commands: 1844 + 1845 +TTN: 1846 + 1847 +[[image:image-20220615092124-2.png]] 1848 + 1849 +Helium: 1850 + 1851 +[[image:image-20220615092551-3.png]] 1852 + 1853 +Chirpstack:The downlink window will not be displayed until the network is accessed 1854 + 1855 +[[image:image-20220615094850-6.png]] 1856 + 1857 +[[image:image-20220615094904-7.png]] 1858 + 1859 +Aws: 1860 + 1861 +[[image:image-20220615092939-4.png]] 1862 + 1863 +== 6.3 How to change the uplink interval? == 1864 + 1865 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]] 1822 1822 ))) 1823 1823 1824 1824 (% _mstvisible="1" %) ... ... @@ -1960,8 +1960,6 @@ 1960 1960 1961 1961 * [[Datasheet, Photos, Decoder, Firmware>>https://www.dropbox.com/home/Products_Public_Document/LoRaWAN%20End%20Node/LHT65N%20Temperature%20%26%20Humidity%20Sensor]] 1962 1962 1963 - 1964 - 1965 1965 = 10. FCC Warning = 1966 1966 1967 1967 (% _mstvisible="1" %)
- image-20220615092034-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +70.9 KB - Content
- image-20220615092124-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.0 KB - Content
- image-20220615092551-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +75.2 KB - Content
- image-20220615092939-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +150.5 KB - Content
- image-20220615094747-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.4 KB - Content
- image-20220615094850-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.3 KB - Content
- image-20220615094904-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.1 KB - Content