Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1604,6 +1604,10 @@ 1604 1604 (% _mstvisible="1" %) 1605 1605 * Example: 0xA301 ~/~/Same as AT+CLRDTA 1606 1606 1607 + 1608 + 1609 + 1610 + 1607 1607 (% _mstvisible="1" %) 1608 1608 == (% _msthash="740532" _msttexthash="701363" _mstvisible="3" %)4.13 Auto Send None-ACK messages(%%) == 1609 1609 ... ... @@ -1627,6 +1627,10 @@ 1627 1627 (% _mstvisible="1" %) 1628 1628 * Example: 0x3401 ~/~/Same as AT+PNACKMD=1 1629 1629 1634 + 1635 + 1636 + 1637 + 1630 1630 (% _mstvisible="1" %) 1631 1631 = (% _msthash="568737" _msttexthash="502827" _mstvisible="3" %)5. Battery & How to replace(%%) = 1632 1632 ... ... @@ -1718,43 +1718,43 @@ 1718 1718 1719 1719 AT+<CMD>? : Help on <CMD> 1720 1720 1721 -AT+<CMD> : Run <CMD> 1729 +AT+<CMD> : Run <CMD> 1722 1722 1723 -AT+<CMD>=<value> : Set the value 1731 +AT+<CMD>=<value> : Set the value 1724 1724 1725 -AT+<CMD>=? : Get the value 1733 +AT+<CMD>=? : Get the value 1726 1726 1727 -AT+DEBUG:Set more info output 1735 +AT+DEBUG: Set more info output 1728 1728 1729 -ATZ: Trig a reset of the MCU 1737 +ATZ: Trig a reset of the MCU 1730 1730 1731 -AT+FDR: Reset Parameters to Factory Default, Keys Reserve 1739 +AT+FDR: Reset Parameters to Factory Default, Keys Reserve 1732 1732 1733 -AT+DEUI: Get or Set the Device EUI 1741 +AT+DEUI: Get or Set the Device EUI 1734 1734 1735 -AT+DADDR: Get or Set the Device Address 1743 +AT+DADDR: Get or Set the Device Address 1736 1736 1737 -AT+APPKEY: Get or Set the Application Key 1745 +AT+APPKEY: Get or Set the Application Key 1738 1738 1739 -AT+NWKSKEY: Get or Set the Network Session Key 1747 +AT+NWKSKEY: Get or Set the Network Session Key 1740 1740 1741 -AT+APPSKEY: Get or Set the Application Session Key 1749 +AT+APPSKEY: Get or Set the Application Session Key 1742 1742 1743 -AT+APPEUI: Get or Set the Application EUI 1751 +AT+APPEUI: Get or Set the Application EUI 1744 1744 1745 -AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 1753 +AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 1746 1746 1747 -AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 1755 +AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 1748 1748 1749 -AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1757 +AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1750 1750 1751 -AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 1759 +AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 1752 1752 1753 -AT+PNM: Get or Set the public network mode. (0: off, 1: on) 1761 +AT+PNM: Get or Set the public network mode. (0: off, 1: on) 1754 1754 1755 -AT+RX2FQ: Get or Set the Rx2 window frequency 1763 +AT+RX2FQ: Get or Set the Rx2 window frequency 1756 1756 1757 -AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 1765 +AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 1758 1758 1759 1759 AT+RX1DL: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 1760 1760