Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2025/07/03 14:48
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,11 +1,10 @@ 1 -(% _mstvisible="2" style="text-align:center" %)2 -[[image:image-20220 523115324-1.jpeg||_mstalt="469677" _mstvisible="4"height="317" width="317"]]1 +(% style="text-align:center" %) 2 +[[image:image-20220613162008-1.png||height="579" width="379"]] 3 3 4 4 5 5 6 6 7 7 8 - 9 9 (% _mstvisible="1" %) 10 10 (% _msthash="315238" _msttexthash="18964465" _mstvisible="3" %)**Table of Contents:** 11 11 ... ... @@ -595,6 +595,9 @@ 595 595 * Sync time OK: 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 596 596 * Unix Time Request:1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 597 597 597 + 598 + 599 + 598 598 (% _mstvisible="1" %) 599 599 == (% _msthash="487097" _msttexthash="454818" _mstvisible="3" %)2.5 Show data on Datacake(%%) == 600 600 ... ... @@ -657,6 +657,10 @@ 657 657 1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range. 658 658 1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover. 659 659 662 + 663 + 664 + 665 + 660 660 (% _mstvisible="1" %) 661 661 === (% _msthash="369915" _msttexthash="342797" _mstvisible="3" %)2.6.2 Unix TimeStamp(%%) === 662 662 ... ... @@ -1132,6 +1132,12 @@ 1132 1132 ((( 1133 1133 (% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %) 1134 1134 For each success downlink, the PURPLE LED will blink once 1141 + 1142 + 1143 + 1144 + 1145 +(% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %) 1146 + 1135 1135 ))) 1136 1136 1137 1137 (% _mstvisible="1" style="text-align: left;" %) ... ... @@ -1162,6 +1162,10 @@ 1162 1162 * -55°C to 125°C 1163 1163 * Working voltage 2.35v ~~ 5v 1164 1164 1177 + 1178 + 1179 + 1180 + 1165 1165 (% _mstvisible="1" style="text-align: left;" %) 1166 1166 = (% _msthash="1940107" _msttexthash="1714063" _mstvisible="3" %)4. Configure LHT65N via AT command or LoRaWAN downlink(%%) = 1167 1167 ... ... @@ -1242,6 +1242,7 @@ 1242 1242 (% _msthash="506254" _msttexthash="1501357" _mstvisible="2" style="text-align: left;" %) 1243 1243 These commands are only valid for LHT65N, as below: 1244 1244 1261 + 1245 1245 (% _msthash="506254" _msttexthash="1501357" _mstvisible="2" style="text-align: left;" %) 1246 1246 1247 1247 ))) ... ... @@ -1376,6 +1376,10 @@ 1376 1376 * 0xA800 **~-~->** AT+PID=0 1377 1377 * 0xA801 **~-~->** AT+PID=1 1378 1378 1396 + 1397 + 1398 + 1399 + 1379 1379 (% _mstvisible="1" style="text-align: left;" %) 1380 1380 == (% _msthash="266344" _msttexthash="242879" _mstvisible="3" %)4.4 Set Password(%%) == 1381 1381 ... ... @@ -1445,6 +1445,10 @@ 1445 1445 (% _mstvisible="1" %) 1446 1446 * There is no downlink command to set to Sleep mode. 1447 1447 1469 + 1470 + 1471 + 1472 + 1448 1448 (% _mstvisible="1" %) 1449 1449 == (% _msthash="336557" _msttexthash="309712" _mstvisible="3" %)4.7 Set system time(%%) == 1450 1450 ... ... @@ -1579,6 +1579,10 @@ 1579 1579 (% _mstvisible="1" %) 1580 1580 * Example: 0xA301 ~/~/Same as AT+CLRDTA 1581 1581 1607 + 1608 + 1609 + 1610 + 1582 1582 (% _mstvisible="1" %) 1583 1583 == (% _msthash="740532" _msttexthash="701363" _mstvisible="3" %)4.13 Auto Send None-ACK messages(%%) == 1584 1584 ... ... @@ -1602,6 +1602,10 @@ 1602 1602 (% _mstvisible="1" %) 1603 1603 * Example: 0x3401 ~/~/Same as AT+PNACKMD=1 1604 1604 1634 + 1635 + 1636 + 1637 + 1605 1605 (% _mstvisible="1" %) 1606 1606 = (% _msthash="568737" _msttexthash="502827" _mstvisible="3" %)5. Battery & How to replace(%%) = 1607 1607 ... ... @@ -1693,43 +1693,43 @@ 1693 1693 1694 1694 AT+<CMD>? : Help on <CMD> 1695 1695 1696 -AT+<CMD> : Run <CMD> 1729 +AT+<CMD> : Run <CMD> 1697 1697 1698 -AT+<CMD>=<value> : Set the value 1731 +AT+<CMD>=<value> : Set the value 1699 1699 1700 -AT+<CMD>=? : Get the value 1733 +AT+<CMD>=? : Get the value 1701 1701 1702 -AT+DEBUG:Set more info output 1735 +AT+DEBUG: Set more info output 1703 1703 1704 -ATZ: Trig a reset of the MCU 1737 +ATZ: Trig a reset of the MCU 1705 1705 1706 -AT+FDR: Reset Parameters to Factory Default, Keys Reserve 1739 +AT+FDR: Reset Parameters to Factory Default, Keys Reserve 1707 1707 1708 -AT+DEUI: Get or Set the Device EUI 1741 +AT+DEUI: Get or Set the Device EUI 1709 1709 1710 -AT+DADDR: Get or Set the Device Address 1743 +AT+DADDR: Get or Set the Device Address 1711 1711 1712 -AT+APPKEY: Get or Set the Application Key 1745 +AT+APPKEY: Get or Set the Application Key 1713 1713 1714 -AT+NWKSKEY: Get or Set the Network Session Key 1747 +AT+NWKSKEY: Get or Set the Network Session Key 1715 1715 1716 -AT+APPSKEY: Get or Set the Application Session Key 1749 +AT+APPSKEY: Get or Set the Application Session Key 1717 1717 1718 -AT+APPEUI: Get or Set the Application EUI 1751 +AT+APPEUI: Get or Set the Application EUI 1719 1719 1720 -AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 1753 +AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 1721 1721 1722 -AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 1755 +AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 1723 1723 1724 -AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1757 +AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1725 1725 1726 -AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 1759 +AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 1727 1727 1728 -AT+PNM: Get or Set the public network mode. (0: off, 1: on) 1761 +AT+PNM: Get or Set the public network mode. (0: off, 1: on) 1729 1729 1730 -AT+RX2FQ: Get or Set the Rx2 window frequency 1763 +AT+RX2FQ: Get or Set the Rx2 window frequency 1731 1731 1732 -AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 1765 +AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 1733 1733 1734 1734 AT+RX1DL: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 1735 1735