Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2025/07/03 14:48
From version 120.7
edited by Xiaoling
on 2022/06/09 18:29
on 2022/06/09 18:29
Change comment:
There is no comment for this version
To version 133.1
edited by Bei Jinggeng
on 2022/06/15 11:46
on 2022/06/15 11:46
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 8 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -1,13 +1,10 @@ 1 -(% _mstvisible="2" style="text-align:center" %)2 -[[image:image-20220 523115324-1.jpeg||_mstalt="469677" _mstvisible="4"height="317" width="317"]]1 +(% style="text-align:center" %) 2 +[[image:image-20220613162008-1.png||height="579" width="379"]] 3 3 4 4 5 -(% _mstvisible="1" %) 6 -(% _msthash="315237" _msttexthash="1697033" _mstvisible="3" %)**LHT65N LoRaWAN Temperature & Humidity Sensor Manual** 7 7 8 8 9 9 10 - 11 11 (% _mstvisible="1" %) 12 12 (% _msthash="315238" _msttexthash="18964465" _mstvisible="3" %)**Table of Contents:** 13 13 ... ... @@ -275,6 +275,7 @@ 275 275 [[image:image-20220522233118-7.png||_mstalt="430430" _mstvisible="3"]] 276 276 277 277 275 + 278 278 (% _mstvisible="1" %) 279 279 === (% _msthash="3537456" _msttexthash="3448549" _mstvisible="3" %)2.3.2 Step 2: Activate LHT65N by pressing the ACT button for more than 5 seconds.(%%) === 280 280 ... ... @@ -285,6 +285,7 @@ 285 285 [[image:image-20220522233300-8.png||_mstalt="428389" _mstvisible="3" height="219" width="722"]] 286 286 287 287 286 + 288 288 (% _mstvisible="1" %) 289 289 == (% _msthash="320879" _msttexthash="294970" _mstvisible="3" %)2.4 Uplink Payload(%%) == 290 290 ... ... @@ -590,6 +590,7 @@ 590 590 * Sync time OK: 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 591 591 * Unix Time Request:1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 592 592 592 + 593 593 (% _mstvisible="1" %) 594 594 == (% _msthash="487097" _msttexthash="454818" _mstvisible="3" %)2.5 Show data on Datacake(%%) == 595 595 ... ... @@ -652,6 +652,8 @@ 652 652 1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range. 653 653 1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover. 654 654 655 + 656 + 655 655 (% _mstvisible="1" %) 656 656 === (% _msthash="369915" _msttexthash="342797" _mstvisible="3" %)2.6.2 Unix TimeStamp(%%) === 657 657 ... ... @@ -1127,9 +1127,14 @@ 1127 1127 ((( 1128 1128 (% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %) 1129 1129 For each success downlink, the PURPLE LED will blink once 1130 -))) 1131 1131 1132 1132 1134 + 1135 + 1136 +(% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %) 1137 + 1138 +))) 1139 + 1133 1133 (% _mstvisible="1" style="text-align: left;" %) 1134 1134 == (% _msthash="112034" _msttexthash="277511" _mstvisible="3" %)2.9 installation(%%) == 1135 1135 ... ... @@ -1240,6 +1240,7 @@ 1240 1240 (% _msthash="506254" _msttexthash="1501357" _mstvisible="2" style="text-align: left;" %) 1241 1241 These commands are only valid for LHT65N, as below: 1242 1242 1250 + 1243 1243 (% _msthash="506254" _msttexthash="1501357" _mstvisible="2" style="text-align: left;" %) 1244 1244 1245 1245 ))) ... ... @@ -1697,135 +1697,164 @@ 1697 1697 1698 1698 AT Command List is as below: 1699 1699 1700 -AT+<CMD>? : Help on <CMD> 1708 +AT+<CMD>? : Help on <CMD> 1701 1701 1702 -AT+<CMD> : Run <CMD> 1710 +AT+<CMD> : Run <CMD> 1703 1703 1704 -AT+<CMD>=<value> : Set the value 1712 +AT+<CMD>=<value> : Set the value 1705 1705 1706 -AT+<CMD>=? : Get the value 1714 +AT+<CMD>=? : Get the value 1707 1707 1708 -AT+DEBUG:Set more info output 1716 +AT+DEBUG: Set more info output 1709 1709 1710 -ATZ: Trig a reset of the MCU 1718 +ATZ: Trig a reset of the MCU 1711 1711 1712 -AT+FDR: Reset Parameters to Factory Default, Keys Reserve 1720 +AT+FDR: Reset Parameters to Factory Default, Keys Reserve 1713 1713 1714 -AT+DEUI: Get or Set the Device EUI 1722 +AT+DEUI: Get or Set the Device EUI 1715 1715 1716 -AT+DADDR: Get or Set the Device Address 1724 +AT+DADDR: Get or Set the Device Address 1717 1717 1718 -AT+APPKEY: Get or Set the Application Key 1726 +AT+APPKEY: Get or Set the Application Key 1719 1719 1720 -AT+NWKSKEY: Get or Set the Network Session Key 1728 +AT+NWKSKEY: Get or Set the Network Session Key 1721 1721 1722 -AT+APPSKEY: Get or Set the Application Session Key 1730 +AT+APPSKEY: Get or Set the Application Session Key 1723 1723 1724 -AT+APPEUI: Get or Set the Application EUI 1732 +AT+APPEUI: Get or Set the Application EUI 1725 1725 1726 -AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 1734 +AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 1727 1727 1728 -AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 1736 +AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 1729 1729 1730 -AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1738 +AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1731 1731 1732 -AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 1740 +AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 1733 1733 1734 -AT+PNM: Get or Set the public network mode. (0: off, 1: on) 1742 +AT+PNM: Get or Set the public network mode. (0: off, 1: on) 1735 1735 1736 -AT+RX2FQ: Get or Set the Rx2 window frequency 1744 +AT+RX2FQ: Get or Set the Rx2 window frequency 1737 1737 1738 -AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 1746 +AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 1739 1739 1740 -AT+RX1DL: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 1748 +AT+RX1DL: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 1741 1741 1742 -AT+RX2DL: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 1750 +AT+RX2DL: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 1743 1743 1744 -AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 1752 +AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 1745 1745 1746 -AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 1754 +AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 1747 1747 1748 -AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 1756 +AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 1749 1749 1750 -AT+NWKID: Get or Set the Network ID 1758 +AT+NWKID: Get or Set the Network ID 1751 1751 1752 -AT+FCU: Get or Set the Frame Counter Uplink 1760 +AT+FCU: Get or Set the Frame Counter Uplink 1753 1753 1754 -AT+FCD: Get or Set the Frame Counter Downlink 1762 +AT+FCD: Get or Set the Frame Counter Downlink 1755 1755 1756 -AT+CLASS: Get or Set the Device Class 1764 +AT+CLASS: Get or Set the Device Class 1757 1757 1758 -AT+JOIN: Join network 1766 +AT+JOIN: Join network 1759 1759 1760 -AT+NJS: Get the join status 1768 +AT+NJS: Get the join status 1761 1761 1762 -AT+SENDB: Send hexadecimal data along with the application port 1770 +AT+SENDB: Send hexadecimal data along with the application port 1763 1763 1764 -AT+SEND: Send text data along with the application port 1772 +AT+SEND: Send text data along with the application port 1765 1765 1766 -AT+RECVB: Print last received data in binary format (with hexadecimal values) 1774 +AT+RECVB: Print last received data in binary format (with hexadecimal values) 1767 1767 1768 -AT+RECV: Print last received data in raw format 1776 +AT+RECV: Print last received data in raw format 1769 1769 1770 -AT+VER: Get current image version and Frequency Band 1778 +AT+VER: Get current image version and Frequency Band 1771 1771 1772 -AT+CFM: Get or Set the confirmation mode (0-1) 1780 +AT+CFM: Get or Set the confirmation mode (0-1) 1773 1773 1774 -AT+CFS: Get confirmation status of the last AT+SEND (0-1) 1782 +AT+CFS: Get confirmation status of the last AT+SEND (0-1) 1775 1775 1776 -AT+SNR: Get the SNR of the last received packet 1784 +AT+SNR: Get the SNR of the last received packet 1777 1777 1778 -AT+RSSI: Get the RSSI of the last received packet 1786 +AT+RSSI: Get the RSSI of the last received packet 1779 1779 1780 -AT+TDC: Get or set the application data transmission interval in ms 1788 +AT+TDC: Get or set the application data transmission interval in ms 1781 1781 1782 -AT+PORT: Get or set the application port 1790 +AT+PORT: Get or set the application port 1783 1783 1784 -AT+DISAT: Disable AT commands 1792 +AT+DISAT: Disable AT commands 1785 1785 1786 -AT+PWORD: Set password, max 9 digits 1794 +AT+PWORD: Set password, max 9 digits 1787 1787 1788 -AT+CHS: Get or Set Frequency (Unit: Hz) for Single Channel Mode 1796 +AT+CHS: Get or Set Frequency (Unit: Hz) for Single Channel Mode 1789 1789 1790 -AT+CHE: Get or Set eight channels mode,Only for US915,AU915,CN470 1798 +AT+CHE: Get or Set eight channels mode,Only for US915,AU915,CN470 1791 1791 1792 -AT+PDTA: Print the sector data from start page to stop page 1800 +AT+PDTA: Print the sector data from start page to stop page 1793 1793 1794 -AT+PLDTA: Print the last few sets of data 1802 +AT+PLDTA: Print the last few sets of data 1795 1795 1796 -AT+CLRDTA: Clear the storage, record position back to 1st 1804 +AT+CLRDTA: Clear the storage, record position back to 1st 1797 1797 1798 -AT+SLEEP: Set sleep mode 1806 +AT+SLEEP: Set sleep mode 1799 1799 1800 -AT+EXT: Get or Set external sensor model 1808 +AT+EXT: Get or Set external sensor model 1801 1801 1802 -AT+BAT: Get the current battery voltage in mV 1810 +AT+BAT: Get the current battery voltage in mV 1803 1803 1804 -AT+CFG: Print all configurations 1812 +AT+CFG: Print all configurations 1805 1805 1806 -AT+WMOD: Get or Set Work Mode 1814 +AT+WMOD: Get or Set Work Mode 1807 1807 1808 -AT+ARTEMP: Get or set the internal Temperature sensor alarm range 1816 +AT+ARTEMP: Get or set the internal Temperature sensor alarm range 1809 1809 1810 -AT+CITEMP: Get or set the internal Temperature sensor collection interval in min 1818 +AT+CITEMP: Get or set the internal Temperature sensor collection interval in min 1811 1811 1812 -AT+SETCNT:Set the count at present 1820 +AT+SETCNT: Set the count at present 1813 1813 1814 -AT+RJTDC: Get or set the ReJoin data transmission interval in min 1822 +AT+RJTDC: Get or set the ReJoin data transmission interval in min 1815 1815 1816 -AT+RPL: Get or set response level 1824 +AT+RPL: Get or set response level 1817 1817 1818 -AT+TIMESTAMP: Get or Set UNIX timestamp in second 1826 +AT+TIMESTAMP: Get or Set UNIX timestamp in second 1819 1819 1820 -AT+LEAPSEC: Get or Set Leap Second 1828 +AT+LEAPSEC: Get or Set Leap Second 1821 1821 1822 -AT+SYNCMOD: Get or Set time synchronization method 1830 +AT+SYNCMOD: Get or Set time synchronization method 1823 1823 1824 -AT+SYNCTDC: Get or set time synchronization interval in day 1832 +AT+SYNCTDC: Get or set time synchronization interval in day 1825 1825 1826 -AT+PID: Get or set the PID 1834 +AT+PID: Get or set the PID 1827 1827 1828 - 1836 + 1837 +== 6.2 Where to use AT commands and Downlink commands == 1838 + 1839 +AT commands: 1840 + 1841 +[[image:image-20220615092034-1.png]] 1842 + 1843 +Downlink commands: 1844 + 1845 +TTN: 1846 + 1847 +[[image:image-20220615092124-2.png]] 1848 + 1849 +Helium: 1850 + 1851 +[[image:image-20220615092551-3.png]] 1852 + 1853 +Chirpstack:The downlink window will not be displayed until the network is accessed 1854 + 1855 +[[image:image-20220615094850-6.png]] 1856 + 1857 +[[image:image-20220615094904-7.png]] 1858 + 1859 +Aws: 1860 + 1861 +[[image:image-20220615092939-4.png]] 1862 + 1863 +== 6.3 How to change the uplink interval? == 1864 + 1865 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]] 1829 1829 ))) 1830 1830 1831 1831 (% _mstvisible="1" %) ... ... @@ -1967,7 +1967,6 @@ 1967 1967 1968 1968 * [[Datasheet, Photos, Decoder, Firmware>>https://www.dropbox.com/home/Products_Public_Document/LoRaWAN%20End%20Node/LHT65N%20Temperature%20%26%20Humidity%20Sensor]] 1969 1969 1970 - 1971 1971 = 10. FCC Warning = 1972 1972 1973 1973 (% _mstvisible="1" %)
- image-20220613162008-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +182.8 KB - Content
- image-20220615092034-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +70.9 KB - Content
- image-20220615092124-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.0 KB - Content
- image-20220615092551-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +75.2 KB - Content
- image-20220615092939-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +150.5 KB - Content
- image-20220615094747-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.4 KB - Content
- image-20220615094850-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.3 KB - Content
- image-20220615094904-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.1 KB - Content