Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Xiaoling on 2025/02/10 11:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,13 +1,10 @@ 1 -(% _mstvisible="2" style="text-align:center" %)2 -[[image:image-20220 523115324-1.jpeg||_mstalt="469677" _mstvisible="4"height="317" width="317"]]1 +(% style="text-align:center" %) 2 +[[image:image-20220613162008-1.png||height="579" width="379"]] 3 3 4 4 5 -(% _mstvisible="1" %) 6 -(% _msthash="315237" _msttexthash="1697033" _mstvisible="3" %)**LHT65N LoRaWAN Temperature & Humidity Sensor Manual** 7 7 8 8 9 9 10 - 11 11 (% _mstvisible="1" %) 12 12 (% _msthash="315238" _msttexthash="18964465" _mstvisible="3" %)**Table of Contents:** 13 13 ... ... @@ -77,6 +77,7 @@ 77 77 * Tri-color LED to indicate working status 78 78 * Datalog feature 79 79 77 + 80 80 (% _mstvisible="1" %) 81 81 == (% _msthash="323570" _msttexthash="297635" _mstvisible="3" %)1.3 Specification(%%) == 82 82 ... ... @@ -275,6 +275,7 @@ 275 275 [[image:image-20220522233118-7.png||_mstalt="430430" _mstvisible="3"]] 276 276 277 277 276 + 278 278 (% _mstvisible="1" %) 279 279 === (% _msthash="3537456" _msttexthash="3448549" _mstvisible="3" %)2.3.2 Step 2: Activate LHT65N by pressing the ACT button for more than 5 seconds.(%%) === 280 280 ... ... @@ -285,6 +285,7 @@ 285 285 [[image:image-20220522233300-8.png||_mstalt="428389" _mstvisible="3" height="219" width="722"]] 286 286 287 287 287 + 288 288 (% _mstvisible="1" %) 289 289 == (% _msthash="320879" _msttexthash="294970" _mstvisible="3" %)2.4 Uplink Payload(%%) == 290 290 ... ... @@ -363,6 +363,7 @@ 363 363 * The 7th byte (EXT #): defines the external sensor model. 364 364 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won’t be these four bytes.) 365 365 366 + 366 366 (% _mstvisible="1" %) 367 367 === (% _msthash="360269" _msttexthash="333762" _mstvisible="3" %)2.4.1 Decoder in TTN V3(%%) === 368 368 ... ... @@ -399,6 +399,7 @@ 399 399 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 400 400 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 401 401 403 + 402 402 (% _mstvisible="1" %) 403 403 === (% _msthash="600769" _msttexthash="565838" _mstvisible="3" %)2.4.3 Built-in Temperature(%%) === 404 404 ... ... @@ -415,8 +415,6 @@ 415 415 * Temperature: (0xF5C6-65536)/100=-26.18℃ 416 416 417 417 418 - 419 - 420 420 (% _mstvisible="1" %) 421 421 === (% _msthash="475891" _msttexthash="445120" _mstvisible="3" %)2.4.4 Built-in Humidity(%%) === 422 422 ... ... @@ -427,8 +427,6 @@ 427 427 * Humidity: 0x025C/10=60.4% 428 428 429 429 430 - 431 - 432 432 (% _mstvisible="1" %) 433 433 === (% _msthash="116532" _msttexthash="87958" _mstvisible="3" %)2.4.5 Ext #(%%) === 434 434 ... ... @@ -555,7 +555,6 @@ 555 555 ))) 556 556 ))) 557 557 558 - 559 559 (% _mstvisible="1" %) 560 560 * (% _msthash="2539669" _msttexthash="857922" _mstvisible="3" %)**Battery status & **(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)**Built-in Humidity** 561 561 ... ... @@ -586,7 +586,6 @@ 586 586 587 587 ))) 588 588 589 - 590 590 (% _mstvisible="1" %) 591 591 * (% _msthash="504956" _msttexthash="245037" _mstvisible="4" %)**Status & Ext Byte** 592 592 ... ... @@ -600,6 +600,7 @@ 600 600 601 601 602 602 599 + 603 603 (% _mstvisible="1" %) 604 604 == (% _msthash="487097" _msttexthash="454818" _mstvisible="3" %)2.5 Show data on Datacake(%%) == 605 605 ... ... @@ -664,6 +664,8 @@ 664 664 665 665 666 666 664 + 665 + 667 667 (% _mstvisible="1" %) 668 668 === (% _msthash="369915" _msttexthash="342797" _mstvisible="3" %)2.6.2 Unix TimeStamp(%%) === 669 669 ... ... @@ -1139,9 +1139,14 @@ 1139 1139 ((( 1140 1140 (% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %) 1141 1141 For each success downlink, the PURPLE LED will blink once 1142 -))) 1143 1143 1144 1144 1143 + 1144 + 1145 +(% _msthash="903008" _msttexthash="1875640" _mstvisible="4" %) 1146 + 1147 +))) 1148 + 1145 1145 (% _mstvisible="1" style="text-align: left;" %) 1146 1146 == (% _msthash="112034" _msttexthash="277511" _mstvisible="3" %)2.9 installation(%%) == 1147 1147 ... ... @@ -1172,6 +1172,8 @@ 1172 1172 1173 1173 1174 1174 1179 + 1180 + 1175 1175 (% _mstvisible="1" style="text-align: left;" %) 1176 1176 = (% _msthash="1940107" _msttexthash="1714063" _mstvisible="3" %)4. Configure LHT65N via AT command or LoRaWAN downlink(%%) = 1177 1177 ... ... @@ -1252,6 +1252,7 @@ 1252 1252 (% _msthash="506254" _msttexthash="1501357" _mstvisible="2" style="text-align: left;" %) 1253 1253 These commands are only valid for LHT65N, as below: 1254 1254 1261 + 1255 1255 (% _msthash="506254" _msttexthash="1501357" _mstvisible="2" style="text-align: left;" %) 1256 1256 1257 1257 ))) ... ... @@ -1388,6 +1388,8 @@ 1388 1388 1389 1389 1390 1390 1398 + 1399 + 1391 1391 (% _mstvisible="1" style="text-align: left;" %) 1392 1392 == (% _msthash="266344" _msttexthash="242879" _mstvisible="3" %)4.4 Set Password(%%) == 1393 1393 ... ... @@ -1459,6 +1459,8 @@ 1459 1459 1460 1460 1461 1461 1471 + 1472 + 1462 1462 (% _mstvisible="1" %) 1463 1463 == (% _msthash="336557" _msttexthash="309712" _mstvisible="3" %)4.7 Set system time(%%) == 1464 1464 ... ... @@ -1595,6 +1595,8 @@ 1595 1595 1596 1596 1597 1597 1609 + 1610 + 1598 1598 (% _mstvisible="1" %) 1599 1599 == (% _msthash="740532" _msttexthash="701363" _mstvisible="3" %)4.13 Auto Send None-ACK messages(%%) == 1600 1600 ... ... @@ -1620,6 +1620,8 @@ 1620 1620 1621 1621 1622 1622 1636 + 1637 + 1623 1623 (% _mstvisible="1" %) 1624 1624 = (% _msthash="568737" _msttexthash="502827" _mstvisible="3" %)5. Battery & How to replace(%%) = 1625 1625 ... ... @@ -1711,105 +1711,105 @@ 1711 1711 1712 1712 AT+<CMD>? : Help on <CMD> 1713 1713 1714 -AT+<CMD> : Run <CMD> 1729 +AT+<CMD> : Run <CMD> 1715 1715 1716 -AT+<CMD>=<value> : Set the value 1731 +AT+<CMD>=<value> : Set the value 1717 1717 1718 -AT+<CMD>=? : Get the value 1733 +AT+<CMD>=? : Get the value 1719 1719 1720 -AT+DEBUG:Set more info output 1735 +AT+DEBUG: Set more info output 1721 1721 1722 -ATZ: Trig a reset of the MCU 1737 +ATZ: Trig a reset of the MCU 1723 1723 1724 -AT+FDR: Reset Parameters to Factory Default, Keys Reserve 1739 +AT+FDR: Reset Parameters to Factory Default, Keys Reserve 1725 1725 1726 -AT+DEUI: Get or Set the Device EUI 1741 +AT+DEUI: Get or Set the Device EUI 1727 1727 1728 -AT+DADDR: Get or Set the Device Address 1743 +AT+DADDR: Get or Set the Device Address 1729 1729 1730 -AT+APPKEY: Get or Set the Application Key 1745 +AT+APPKEY: Get or Set the Application Key 1731 1731 1732 -AT+NWKSKEY: Get or Set the Network Session Key 1747 +AT+NWKSKEY: Get or Set the Network Session Key 1733 1733 1734 -AT+APPSKEY: Get or Set the Application Session Key 1749 +AT+APPSKEY: Get or Set the Application Session Key 1735 1735 1736 -AT+APPEUI: Get or Set the Application EUI 1751 +AT+APPEUI: Get or Set the Application EUI 1737 1737 1738 -AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 1753 +AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 1739 1739 1740 -AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 1755 +AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 1741 1741 1742 -AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1757 +AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1743 1743 1744 -AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 1759 +AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 1745 1745 1746 -AT+PNM: Get or Set the public network mode. (0: off, 1: on) 1761 +AT+PNM: Get or Set the public network mode. (0: off, 1: on) 1747 1747 1748 -AT+RX2FQ: Get or Set the Rx2 window frequency 1763 +AT+RX2FQ: Get or Set the Rx2 window frequency 1749 1749 1750 -AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 1765 +AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 1751 1751 1752 -AT+RX1DL: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 1767 +AT+RX1DL: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 1753 1753 1754 -AT+RX2DL: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 1769 +AT+RX2DL: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 1755 1755 1756 -AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 1771 +AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 1757 1757 1758 -AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 1773 +AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 1759 1759 1760 -AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 1775 +AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 1761 1761 1762 -AT+NWKID: Get or Set the Network ID 1777 +AT+NWKID: Get or Set the Network ID 1763 1763 1764 -AT+FCU: Get or Set the Frame Counter Uplink 1779 +AT+FCU: Get or Set the Frame Counter Uplink 1765 1765 1766 -AT+FCD: Get or Set the Frame Counter Downlink 1781 +AT+FCD: Get or Set the Frame Counter Downlink 1767 1767 1768 -AT+CLASS: Get or Set the Device Class 1783 +AT+CLASS: Get or Set the Device Class 1769 1769 1770 -AT+JOIN: Join network 1785 +AT+JOIN: Join network 1771 1771 1772 -AT+NJS: Get the join status 1787 +AT+NJS: Get the join status 1773 1773 1774 -AT+SENDB: Send hexadecimal data along with the application port 1789 +AT+SENDB: Send hexadecimal data along with the application port 1775 1775 1776 -AT+SEND: Send text data along with the application port 1791 +AT+SEND: Send text data along with the application port 1777 1777 1778 -AT+RECVB: Print last received data in binary format (with hexadecimal values) 1793 +AT+RECVB: Print last received data in binary format (with hexadecimal values) 1779 1779 1780 -AT+RECV: Print last received data in raw format 1795 +AT+RECV: Print last received data in raw format 1781 1781 1782 -AT+VER: Get current image version and Frequency Band 1797 +AT+VER: Get current image version and Frequency Band 1783 1783 1784 -AT+CFM: Get or Set the confirmation mode (0-1) 1799 +AT+CFM: Get or Set the confirmation mode (0-1) 1785 1785 1786 -AT+CFS: Get confirmation status of the last AT+SEND (0-1) 1801 +AT+CFS: Get confirmation status of the last AT+SEND (0-1) 1787 1787 1788 -AT+SNR: Get the SNR of the last received packet 1803 +AT+SNR: Get the SNR of the last received packet 1789 1789 1790 -AT+RSSI: Get the RSSI of the last received packet 1805 +AT+RSSI: Get the RSSI of the last received packet 1791 1791 1792 -AT+TDC: Get or set the application data transmission interval in ms 1807 +AT+TDC: Get or set the application data transmission interval in ms 1793 1793 1794 -AT+PORT: Get or set the application port 1809 +AT+PORT: Get or set the application port 1795 1795 1796 -AT+DISAT: Disable AT commands 1811 +AT+DISAT: Disable AT commands 1797 1797 1798 -AT+PWORD: Set password, max 9 digits 1813 +AT+PWORD: Set password, max 9 digits 1799 1799 1800 -AT+CHS: Get or Set Frequency (Unit: Hz) for Single Channel Mode 1815 +AT+CHS: Get or Set Frequency (Unit: Hz) for Single Channel Mode 1801 1801 1802 -AT+CHE: Get or Set eight channels mode,Only for US915,AU915,CN470 1817 +AT+CHE: Get or Set eight channels mode,Only for US915,AU915,CN470 1803 1803 1804 -AT+PDTA: Print the sector data from start page to stop page 1819 +AT+PDTA: Print the sector data from start page to stop page 1805 1805 1806 -AT+PLDTA: Print the last few sets of data 1821 +AT+PLDTA: Print the last few sets of data 1807 1807 1808 -AT+CLRDTA: Clear the storage, record position back to 1st 1823 +AT+CLRDTA: Clear the storage, record position back to 1st 1809 1809 1810 -AT+SLEEP: Set sleep mode 1825 +AT+SLEEP: Set sleep mode 1811 1811 1812 -AT+EXT: Get or Set external sensor model 1827 +AT+EXT: Get or Set external sensor model 1813 1813 1814 1814 AT+BAT: Get the current battery voltage in mV 1815 1815 ... ... @@ -1980,6 +1980,7 @@ 1980 1980 * [[Datasheet, Photos, Decoder, Firmware>>https://www.dropbox.com/home/Products_Public_Document/LoRaWAN%20End%20Node/LHT65N%20Temperature%20%26%20Humidity%20Sensor]] 1981 1981 1982 1982 1998 + 1983 1983 = 10. FCC Warning = 1984 1984 1985 1985 (% _mstvisible="1" %)
- image-20220613162008-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +182.8 KB - Content