<
From version < 119.29 >
edited by Xiaoling
on 2022/06/09 18:28
To version < 120.8 >
edited by Xiaoling
on 2022/06/09 18:29
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -363,7 +363,6 @@
363 363  * The 7th byte (EXT #): defines the external sensor model.
364 364  * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won’t be these four bytes.)
365 365  
366 -
367 367  (% _mstvisible="1" %)
368 368  === (% _msthash="360269" _msttexthash="333762" _mstvisible="3" %)2.4.1 Decoder in TTN V3(%%) ===
369 369  
... ... @@ -400,7 +400,6 @@
400 400  * BAT status=(0Xcba4>>14)&0xFF=11(B),very good
401 401  * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV
402 402  
403 -
404 404  (% _mstvisible="1" %)
405 405  === (% _msthash="600769" _msttexthash="565838" _mstvisible="3" %)2.4.3 Built-in Temperature(%%) ===
406 406  
... ... @@ -416,7 +416,6 @@
416 416  (% _mstvisible="1" %)
417 417  * Temperature:  (0xF5C6-65536)/100=-26.18℃
418 418  
419 -
420 420  (% _mstvisible="1" %)
421 421  === (% _msthash="475891" _msttexthash="445120" _mstvisible="3" %)2.4.4 Built-in Humidity(%%) ===
422 422  
... ... @@ -655,6 +655,8 @@
655 655  1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range.
656 656  1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover.
657 657  
655 +
656 +
658 658  (% _mstvisible="1" %)
659 659  === (% _msthash="369915" _msttexthash="342797" _mstvisible="3" %)2.6.2 Unix TimeStamp(%%) ===
660 660  
... ... @@ -1133,7 +1133,6 @@
1133 1133  )))
1134 1134  
1135 1135  
1136 -
1137 1137  (% _mstvisible="1" style="text-align: left;" %)
1138 1138  == (% _msthash="112034" _msttexthash="277511" _mstvisible="3" %)2.9 installation(%%) ==
1139 1139  
... ... @@ -1163,6 +1163,7 @@
1163 1163  * Working voltage 2.35v ~~ 5v
1164 1164  
1165 1165  
1164 +
1166 1166  (% _mstvisible="1" style="text-align: left;" %)
1167 1167  = (% _msthash="1940107" _msttexthash="1714063" _mstvisible="3" %)4. Configure LHT65N via AT command or LoRaWAN downlink(%%) =
1168 1168  
... ... @@ -1369,6 +1369,7 @@
1369 1369  (% _mstvisible="1" %)
1370 1370  [[image:image-20220523150928-4.png||_mstalt="431821" _mstvisible="3"]]
1371 1371  
1371 +
1372 1372  (% _mstvisible="1" style="text-align: left;" %)
1373 1373  (% style="color:#4f81bd" %)**Downlink Command:**
1374 1374  
... ... @@ -1377,6 +1377,7 @@
1377 1377  * 0xA801     **~-~->** AT+PID=1
1378 1378  
1379 1379  
1380 +
1380 1380  (% _mstvisible="1" style="text-align: left;" %)
1381 1381  == (% _msthash="266344" _msttexthash="242879" _mstvisible="3" %)4.4 Set Password(%%) ==
1382 1382  
... ... @@ -1447,6 +1447,7 @@
1447 1447  * There is no downlink command to set to Sleep mode.
1448 1448  
1449 1449  
1451 +
1450 1450  (% _mstvisible="1" %)
1451 1451  == (% _msthash="336557" _msttexthash="309712" _mstvisible="3" %)4.7 Set system time(%%) ==
1452 1452  
... ... @@ -1582,6 +1582,7 @@
1582 1582  * Example: 0xA301 ~/~/Same as AT+CLRDTA
1583 1583  
1584 1584  
1587 +
1585 1585  (% _mstvisible="1" %)
1586 1586  == (% _msthash="740532" _msttexthash="701363" _mstvisible="3" %)4.13 Auto Send None-ACK messages(%%) ==
1587 1587  
... ... @@ -1599,7 +1599,6 @@
1599 1599  (% _mstvisible="3" %)|=(% _mstvisible="4" style="width: 171px;" %)(% _msthash="1231737" _msttexthash="251862" _mstvisible="6" %)**Command Example**|=(% _mstvisible="4" style="width: 219px;" %)(% _msthash="1231738" _msttexthash="116025" _mstvisible="6" %)**Function**|=(% _mstvisible="4" style="width: 119px;" %)(% _msthash="1231739" _msttexthash="116831" _mstvisible="6" %)**Response**
1600 1600  (% _mstvisible="3" %)|(% _msthash="1231321" _msttexthash="130455" _mstvisible="4" style="width:171px" %)AT+PNACKMD=1|(% _msthash="1231322" _msttexthash="377026" _mstvisible="4" style="width:219px" %)Poll None-ACK message|(% _msthash="1231323" _msttexthash="14989" _mstvisible="4" style="width:119px" %)OK
1601 1601  
1602 -
1603 1603  (% _mstvisible="1" %)
1604 1604  (% style="color:#4f81bd" %)**Downlink Command: 0x34**
1605 1605  
... ... @@ -1607,6 +1607,7 @@
1607 1607  * Example: 0x3401 ~/~/Same as AT+PNACKMD=1
1608 1608  
1609 1609  
1612 +
1610 1610  (% _mstvisible="1" %)
1611 1611  = (% _msthash="568737" _msttexthash="502827" _mstvisible="3" %)5. Battery & How to replace(%%) =
1612 1612  
... ... @@ -1674,7 +1674,7 @@
1674 1674  
1675 1675  **Connection:**
1676 1676  
1677 -✓** USB to TTL GND <~-~->GND**
1680 +✓** USB to TTL GND <~-~->GND**
1678 1678  
1679 1679  **✓ USB to TTL RXD <~-~-> D+**
1680 1680  
... ... @@ -1967,7 +1967,6 @@
1967 1967  * [[Datasheet, Photos, Decoder, Firmware>>https://www.dropbox.com/home/Products_Public_Document/LoRaWAN%20End%20Node/LHT65N%20Temperature%20%26%20Humidity%20Sensor]]
1968 1968  
1969 1969  
1970 -
1971 1971  = 10. FCC Warning =
1972 1972  
1973 1973  (% _mstvisible="1" %)
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0