<
From version < 119.29 >
edited by Xiaoling
on 2022/06/09 18:28
To version < 119.23 >
edited by Xiaoling
on 2022/06/09 18:23
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1645,18 +1645,11 @@
1645 1645  (% _mstvisible="1" %)
1646 1646  (((
1647 1647  (% _msthash="506266" _msttexthash="35479028" _mstvisible="2" %)
1648 -(((
1649 1649  Dragino battery-powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimated battery life:
1650 1650  [[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]]
1651 -)))
1652 1652  
1653 -(((
1654 -
1655 -)))
1656 1656  
1657 -(((
1658 1658  A full detail test report for LHT65N on different frequency can be found at : [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]]
1659 -)))
1660 1660  
1661 1661  
1662 1662  (% _msthash="506266" _msttexthash="35479028" _mstvisible="2" %)
... ... @@ -1665,31 +1665,34 @@
1665 1665  (% _msthash="506266" _msttexthash="35479028" _mstvisible="2" %)
1666 1666  == 6.1 How to use AT Command? ==
1667 1667  
1668 -(((
1669 -LHT65N supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below.
1670 -)))
1661 +LHT65N supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to
1671 1671  
1663 +connect to LHT65 for using AT command, as below.
1664 +
1672 1672  [[image:image-20220530085651-1.png]]
1673 1673  
1674 1674  
1675 -**Connection:**
1668 +Connection:
1676 1676  
1677 -✓** USB to TTL GND <~-~->GND**
1670 +✓ USB to TTL GND <~-~->GND
1678 1678  
1679 -**✓ USB to TTL RXD <~-~-> D+**
1672 +✓ USB to TTL RXD <~-~-> D+
1680 1680  
1681 -**✓ USB to TTL TXD <~-~-> A11**
1674 +✓ USB to TTL TXD <~-~-> A11
1682 1682  
1683 -**✓ USB to TTL 3.3V <~-~-> D-**
1676 +✓ USB to TTL 3.3V <~-~-> D-
1684 1684  
1678 +In PC, User needs to set serial tool(such as **putty**, SecureCRT) baud rate to **9600** to access to
1685 1685  
1686 -(((
1687 -In PC, User needs to set serial tool(such as **putty**, SecureCRT) baud rate to **9600** to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:**123456**) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
1688 -)))
1680 +access serial console for LHT65N. The AT commands are disable by default and need to enter
1689 1689  
1690 -(((
1682 +password (default:**123456**) to active it. Timeout to input AT Command is 5 min, after 5-minute,
1683 +
1684 +user need to input password again. User can use AT+DISAT command to disable AT command
1685 +
1686 +before timeout.
1687 +
1691 1691  Input password and ATZ to activate LHT65N,As shown below:
1692 -)))
1693 1693  
1694 1694  [[image:image-20220530095701-4.png]]
1695 1695  
... ... @@ -1740,10 +1740,14 @@
1740 1740  
1741 1741  AT+RX2DL: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms
1742 1742  
1743 -AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms
1739 +AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1
1744 1744  
1745 -AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms
1741 +in ms
1746 1746  
1743 +AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2
1744 +
1745 +in ms
1746 +
1747 1747  AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA)
1748 1748  
1749 1749  AT+NWKID: Get or Set the Network ID
... ... @@ -1907,9 +1907,6 @@
1907 1907  (% _mstvisible="1" %)
1908 1908  (((
1909 1909  (% _msthash="506270" _msttexthash="295386" _mstvisible="2" %)
1910 -
1911 -
1912 -(% _msthash="506270" _msttexthash="295386" _mstvisible="2" %)
1913 1913  (% _mstvisible="3" %)**Package Includes**(%%):
1914 1914  )))
1915 1915  
... ... @@ -1956,10 +1956,6 @@
1956 1956  (((
1957 1957  (% _msthash="903342" _msttexthash="227084" _mstvisible="4" %)
1958 1958  Weight / pcs : 170g
1959 -
1960 -
1961 -(% _msthash="903342" _msttexthash="227084" _mstvisible="4" %)
1962 -
1963 1963  )))
1964 1964  
1965 1965  = 9. Reference =
... ... @@ -1966,8 +1966,6 @@
1966 1966  
1967 1967  * [[Datasheet, Photos, Decoder, Firmware>>https://www.dropbox.com/home/Products_Public_Document/LoRaWAN%20End%20Node/LHT65N%20Temperature%20%26%20Humidity%20Sensor]]
1968 1968  
1969 -
1970 -
1971 1971  = 10. FCC Warning =
1972 1972  
1973 1973  (% _mstvisible="1" %)
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0