Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,6 +77,8 @@ 77 77 * Tri-color LED to indicate working status 78 78 * Datalog feature 79 79 80 + 81 + 80 80 (% _mstvisible="1" %) 81 81 == (% _msthash="323570" _msttexthash="297635" _mstvisible="3" %)1.3 Specification(%%) == 82 82 ... ... @@ -275,6 +275,7 @@ 275 275 [[image:image-20220522233118-7.png||_mstalt="430430" _mstvisible="3"]] 276 276 277 277 280 + 278 278 (% _mstvisible="1" %) 279 279 === (% _msthash="3537456" _msttexthash="3448549" _mstvisible="3" %)2.3.2 Step 2: Activate LHT65N by pressing the ACT button for more than 5 seconds.(%%) === 280 280 ... ... @@ -285,6 +285,7 @@ 285 285 [[image:image-20220522233300-8.png||_mstalt="428389" _mstvisible="3" height="219" width="722"]] 286 286 287 287 291 + 288 288 (% _mstvisible="1" %) 289 289 == (% _msthash="320879" _msttexthash="294970" _mstvisible="3" %)2.4 Uplink Payload(%%) == 290 290 ... ... @@ -364,6 +364,7 @@ 364 364 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won’t be these four bytes.) 365 365 366 366 371 + 367 367 (% _mstvisible="1" %) 368 368 === (% _msthash="360269" _msttexthash="333762" _mstvisible="3" %)2.4.1 Decoder in TTN V3(%%) === 369 369 ... ... @@ -401,6 +401,7 @@ 401 401 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 402 402 403 403 409 + 404 404 (% _mstvisible="1" %) 405 405 === (% _msthash="600769" _msttexthash="565838" _mstvisible="3" %)2.4.3 Built-in Temperature(%%) === 406 406 ... ... @@ -417,6 +417,7 @@ 417 417 * Temperature: (0xF5C6-65536)/100=-26.18℃ 418 418 419 419 426 + 420 420 (% _mstvisible="1" %) 421 421 === (% _msthash="475891" _msttexthash="445120" _mstvisible="3" %)2.4.4 Built-in Humidity(%%) === 422 422 ... ... @@ -426,6 +426,8 @@ 426 426 (% _mstvisible="1" %) 427 427 * Humidity: 0x025C/10=60.4% 428 428 436 + 437 + 429 429 (% _mstvisible="1" %) 430 430 === (% _msthash="116532" _msttexthash="87958" _mstvisible="3" %)2.4.5 Ext #(%%) === 431 431 ... ... @@ -593,6 +593,7 @@ 593 593 * Sync time OK: 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 594 594 * Unix Time Request:1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 595 595 605 + 596 596 (% _mstvisible="1" %) 597 597 == (% _msthash="487097" _msttexthash="454818" _mstvisible="3" %)2.5 Show data on Datacake(%%) == 598 598 ... ... @@ -655,6 +655,7 @@ 655 655 1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range. 656 656 1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover. 657 657 668 + 658 658 (% _mstvisible="1" %) 659 659 === (% _msthash="369915" _msttexthash="342797" _mstvisible="3" %)2.6.2 Unix TimeStamp(%%) === 660 660 ... ... @@ -1132,8 +1132,6 @@ 1132 1132 For each success downlink, the PURPLE LED will blink once 1133 1133 ))) 1134 1134 1135 - 1136 - 1137 1137 (% _mstvisible="1" style="text-align: left;" %) 1138 1138 == (% _msthash="112034" _msttexthash="277511" _mstvisible="3" %)2.9 installation(%%) == 1139 1139 ... ... @@ -1369,6 +1369,7 @@ 1369 1369 (% _mstvisible="1" %) 1370 1370 [[image:image-20220523150928-4.png||_mstalt="431821" _mstvisible="3"]] 1371 1371 1381 + 1372 1372 (% _mstvisible="1" style="text-align: left;" %) 1373 1373 (% style="color:#4f81bd" %)**Downlink Command:** 1374 1374 ... ... @@ -1599,7 +1599,6 @@ 1599 1599 (% _mstvisible="3" %)|=(% _mstvisible="4" style="width: 171px;" %)(% _msthash="1231737" _msttexthash="251862" _mstvisible="6" %)**Command Example**|=(% _mstvisible="4" style="width: 219px;" %)(% _msthash="1231738" _msttexthash="116025" _mstvisible="6" %)**Function**|=(% _mstvisible="4" style="width: 119px;" %)(% _msthash="1231739" _msttexthash="116831" _mstvisible="6" %)**Response** 1600 1600 (% _mstvisible="3" %)|(% _msthash="1231321" _msttexthash="130455" _mstvisible="4" style="width:171px" %)AT+PNACKMD=1|(% _msthash="1231322" _msttexthash="377026" _mstvisible="4" style="width:219px" %)Poll None-ACK message|(% _msthash="1231323" _msttexthash="14989" _mstvisible="4" style="width:119px" %)OK 1601 1601 1602 - 1603 1603 (% _mstvisible="1" %) 1604 1604 (% style="color:#4f81bd" %)**Downlink Command: 0x34** 1605 1605 ... ... @@ -1645,11 +1645,18 @@ 1645 1645 (% _mstvisible="1" %) 1646 1646 ((( 1647 1647 (% _msthash="506266" _msttexthash="35479028" _mstvisible="2" %) 1657 +((( 1648 1648 Dragino battery-powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimated battery life: 1649 1649 [[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]] 1660 +))) 1650 1650 1662 +((( 1663 + 1664 +))) 1651 1651 1666 +((( 1652 1652 A full detail test report for LHT65N on different frequency can be found at : [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]] 1668 +))) 1653 1653 1654 1654 1655 1655 (% _msthash="506266" _msttexthash="35479028" _mstvisible="2" %) ... ... @@ -1658,34 +1658,31 @@ 1658 1658 (% _msthash="506266" _msttexthash="35479028" _mstvisible="2" %) 1659 1659 == 6.1 How to use AT Command? == 1660 1660 1661 -LHT65N supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to 1677 +((( 1678 +LHT65N supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below. 1679 +))) 1662 1662 1663 -connect to LHT65 for using AT command, as below. 1664 - 1665 1665 [[image:image-20220530085651-1.png]] 1666 1666 1667 1667 1668 -Connection: 1684 +**Connection:** 1669 1669 1670 -✓ 1686 +✓** USB to TTL GND <~-~->GND** 1671 1671 1672 -✓ USB to TTL RXD <~-~-> D+ 1688 +**✓ USB to TTL RXD <~-~-> D+** 1673 1673 1674 -✓ USB to TTL TXD <~-~-> A11 1690 +**✓ USB to TTL TXD <~-~-> A11** 1675 1675 1676 -✓ USB to TTL 3.3V <~-~-> D- 1692 +**✓ USB to TTL 3.3V <~-~-> D-** 1677 1677 1678 -In PC, User needs to set serial tool(such as **putty**, SecureCRT) baud rate to **9600** to access to 1679 1679 1680 -access serial console for LHT65N. The AT commands are disable by default and need to enter 1695 +((( 1696 +In PC, User needs to set serial tool(such as **putty**, SecureCRT) baud rate to **9600** to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:**123456**) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 1697 +))) 1681 1681 1682 -password (default:**123456**) to active it. Timeout to input AT Command is 5 min, after 5-minute, 1683 - 1684 -user need to input password again. User can use AT+DISAT command to disable AT command 1685 - 1686 -before timeout. 1687 - 1699 +((( 1688 1688 Input password and ATZ to activate LHT65N,As shown below: 1701 +))) 1689 1689 1690 1690 [[image:image-20220530095701-4.png]] 1691 1691 ... ... @@ -1736,14 +1736,10 @@ 1736 1736 1737 1737 AT+RX2DL: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 1738 1738 1739 -AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 1752 +AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 1740 1740 1741 -in ms 1754 +AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 1742 1742 1743 -AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 1744 - 1745 -in ms 1746 - 1747 1747 AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 1748 1748 1749 1749 AT+NWKID: Get or Set the Network ID ... ... @@ -1907,6 +1907,9 @@ 1907 1907 (% _mstvisible="1" %) 1908 1908 ((( 1909 1909 (% _msthash="506270" _msttexthash="295386" _mstvisible="2" %) 1919 + 1920 + 1921 +(% _msthash="506270" _msttexthash="295386" _mstvisible="2" %) 1910 1910 (% _mstvisible="3" %)**Package Includes**(%%): 1911 1911 ))) 1912 1912 ... ... @@ -1953,6 +1953,10 @@ 1953 1953 ((( 1954 1954 (% _msthash="903342" _msttexthash="227084" _mstvisible="4" %) 1955 1955 Weight / pcs : 170g 1968 + 1969 + 1970 +(% _msthash="903342" _msttexthash="227084" _mstvisible="4" %) 1971 + 1956 1956 ))) 1957 1957 1958 1958 = 9. Reference = ... ... @@ -1959,6 +1959,9 @@ 1959 1959 1960 1960 * [[Datasheet, Photos, Decoder, Firmware>>https://www.dropbox.com/home/Products_Public_Document/LoRaWAN%20End%20Node/LHT65N%20Temperature%20%26%20Humidity%20Sensor]] 1961 1961 1978 + 1979 + 1980 + 1962 1962 = 10. FCC Warning = 1963 1963 1964 1964 (% _mstvisible="1" %)