Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1665,27 +1665,24 @@ 1665 1665 [[image:image-20220530085651-1.png]] 1666 1666 1667 1667 1668 -Connection: 1668 +**Connection:** 1669 1669 1670 -✓ USB to TTL GND <~-~->GND 1670 +✓** USB to TTL GND <~-~->GND** 1671 1671 1672 -✓ USB to TTL RXD <~-~-> D+ 1672 +**✓ USB to TTL RXD <~-~-> D+** 1673 1673 1674 -✓ USB to TTL TXD <~-~-> A11 1674 +**✓ USB to TTL TXD <~-~-> A11** 1675 1675 1676 -✓ USB to TTL 3.3V <~-~-> D- 1676 +**✓ USB to TTL 3.3V <~-~-> D-** 1677 1677 1678 -In PC, User needs to set serial tool(such as **putty**, SecureCRT) baud rate to **9600** to access to 1679 1679 1680 -access serial console for LHT65N. The AT commands are disable by default and need to enter 1679 +((( 1680 +In PC, User needs to set serial tool(such as **putty**, SecureCRT) baud rate to **9600** to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:**123456**) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 1681 +))) 1681 1681 1682 -password (default:**123456**) to active it. Timeout to input AT Command is 5 min, after 5-minute, 1683 - 1684 -user need to input password again. User can use AT+DISAT command to disable AT command 1685 - 1686 -before timeout. 1687 - 1683 +((( 1688 1688 Input password and ATZ to activate LHT65N,As shown below: 1685 +))) 1689 1689 1690 1690 [[image:image-20220530095701-4.png]] 1691 1691 ... ... @@ -1736,14 +1736,10 @@ 1736 1736 1737 1737 AT+RX2DL: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 1738 1738 1739 -AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 1736 +AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 1740 1740 1741 -in ms 1738 +AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 1742 1742 1743 -AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 1744 - 1745 -in ms 1746 - 1747 1747 AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 1748 1748 1749 1749 AT+NWKID: Get or Set the Network ID ... ... @@ -1953,6 +1953,10 @@ 1953 1953 ((( 1954 1954 (% _msthash="903342" _msttexthash="227084" _mstvisible="4" %) 1955 1955 Weight / pcs : 170g 1949 + 1950 + 1951 +(% _msthash="903342" _msttexthash="227084" _mstvisible="4" %) 1952 + 1956 1956 ))) 1957 1957 1958 1958 = 9. Reference = ... ... @@ -1959,6 +1959,8 @@ 1959 1959 1960 1960 * [[Datasheet, Photos, Decoder, Firmware>>https://www.dropbox.com/home/Products_Public_Document/LoRaWAN%20End%20Node/LHT65N%20Temperature%20%26%20Humidity%20Sensor]] 1961 1961 1959 + 1960 + 1962 1962 = 10. FCC Warning = 1963 1963 1964 1964 (% _mstvisible="1" %)