<
From version < 105.1 >
edited by Bei Jinggeng
on 2022/05/25 16:30
To version < 101.1 >
edited by Edwin Chen
on 2022/05/25 11:50
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Edwin
Content
... ... @@ -554,7 +554,7 @@
554 554  )))
555 555  )))|(% style="width:86px" %)(((
556 556  (((
557 -Poll message flag & Ext
557 +[[Poll message flag & Ext>>||anchor="H2.6.4DatalogUplinkpayload"]]
558 558  )))
559 559  )))|(% style="width:48px" %)(((
560 560  (((
... ... @@ -672,32 +672,32 @@
672 672  
673 673  Unix time is 0x60065F97=1611030423s=21/1/19 04:27:03
674 674  
675 -
676 676  == 2.7 Alarm Mode ==
677 677  
678 -Alarm mode feature is added since firmware v1.5. When device is in Alarm mode, it will check the built-in sensor temperature in a short interval. If the temperature exceeds the pre-configure range, it will send an uplink immediately.
677 +When device is in Alarm mode, it will check the built-in sensor temperature in a short interval. If the temperature exceeds the pre-configure range, it will send an uplink immediately.
679 679  
680 680  (((
681 681  (% style="color:red" %)Note: Alarm mode will increase a little big the power consumption, we recommend extending the normal reading time when enabling this feature.
682 682  )))
683 683  
683 +(((
684 684  **AT Commands for Alarm mode:**
685 +)))
685 685  
686 686  (% class="box infomessage" %)
687 687  (((
688 -**~ AT+WMOD=1**: Enable/Disable Alarm Mode. (0:Disable, 1: Enable)
689 +(((
690 +**AT+WMOD=1**: Enable/Disable Alarm Mode. (0:Disable, 1: Enable)
691 +)))
692 +)))
689 689  
690 -(% class="box infomessage" %)**AT**(%%)**+CITEMP=1**: The interval to check the temperature for Alarm. (Unit: minute)
691 -
692 -(% class="box infomessage" %)**AT+ARTEMP:**(%%) Get or set the internal Temperature sensor alarm range
693 -
694 -(% class="box infomessage" %)**AT+ARTEMP=?**(%%):Get the internal Temperatuere sensor alarm range
695 -
696 -(% class="box infomessage" %)**AT+**(% class="box infomessage box infomessage" %)**ARTEMP=45,105**(%%) :Set the internal Temperatuere sensor alarm range 45 to 105.
694 +(% class="box infomessage" %)
695 +(((
696 +(((
697 +**AT+CITEMP=1**: The interval to check the temperature for Alarm. (Unit: minute)
697 697  )))
699 +)))
698 698  
699 -== ==
700 -
701 701  == 2.8 LED Indicator ==
702 702  
703 703  (((
... ... @@ -916,7 +916,7 @@
916 916  
917 917  == 4.7 Set system time ==
918 918  
919 -Feature: Set system time, unix format. [[See here for format detail.>>||anchor="H2.6.2UnixTimeStamp"]]
919 +Feature: Set system time, unix format. [[See here for format detail.>>path:#TimeStamp]]
920 920  
921 921  **AT Command:**
922 922  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0