... ... @@ -554,7 +554,7 @@
554 554  )))
555 555  )))|(% style="width:86px" %)(((
556 556  (((
557 -[[Poll message flag & Ext>>||anchor="H2.6.4DatalogUplinkpayload"]]
557 +Poll message flag & Ext
558 558  )))
559 559  )))|(% style="width:48px" %)(((
560 560  (((
... ... @@ -672,32 +672,32 @@
672 672  
673 673  Unix time is 0x60065F97=1611030423s=21/1/19 04:27:03
674 674  
675 +
675 675  == 2.7 Alarm Mode ==
676 676  
677 -When device is in Alarm mode, it will check the built-in sensor temperature in a short interval. If the temperature exceeds the pre-configure range, it will send an uplink immediately.
678 +Alarm mode feature is added since firmware v1.5. When device is in Alarm mode, it will check the built-in sensor temperature in a short interval. If the temperature exceeds the pre-configure range, it will send an uplink immediately.
678 678  
679 679  (((
680 680  (% style="color:red" %)Note: Alarm mode will increase a little big the power consumption, we recommend extending the normal reading time when enabling this feature.
681 681  )))
682 682  
683 -(((
684 684  **AT Commands for Alarm mode:**
685 -)))
686 686  
687 687  (% class="box infomessage" %)
688 688  (((
689 -(((
690 -**AT+WMOD=1**: Enable/Disable Alarm Mode. (0:Disable, 1: Enable)
691 -)))
692 -)))
688 +**~ AT+WMOD=1**: Enable/Disable Alarm Mode. (0:Disable, 1: Enable)
693 693  
694 -(% class="box infomessage" %)
695 -(((
696 -(((
697 -**AT+CITEMP=1**: The interval to check the temperature for Alarm. (Unit: minute)
690 +(% class="box infomessage" %)**AT**(%%)**+CITEMP=1**: The interval to check the temperature for Alarm. (Unit: minute)
691 +
692 +(% class="box infomessage" %)**AT+ARTEMP** :(%%)Get or set the internal Temperature sensor alarm range
693 +
694 +(% class="box infomessage" %)**AT+ARTEMP=?**(%%):Get the internal Temperatuere sensor alarm range (% style="display:none" %)
695 +
696 +(% class="box infomessage" %)**AT+**(% class="box box infomessage infomessage" %)**ARTEMP=45,105**(%%) :Set the internal Temperatuere sensor alarm range 45 to 105.
698 698  )))
699 -)))
700 700  
699 +== ==
700 +
701 701  == 2.8 LED Indicator ==
702 702  
703 703  (((
... ... @@ -916,7 +916,7 @@
916 916  
917 917  == 4.7 Set system time ==
918 918  
919 -Feature: Set system time, unix format. [[See here for format detail.>>path:#TimeStamp]]
919 +Feature: Set system time, unix format. [[See here for format detail.>>||anchor="H2.6.2UnixTimeStamp"]]
920 920  
921 921  **AT Command:**
922 922  