Changes for page LA66 USB LoRaWAN Adapter User Manual
Last modified by Xiaoling on 2025/02/07 16:37
From version 174.1
edited by Bei Jinggeng
on 2024/03/19 09:45
on 2024/03/19 09:45
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -84,7 +84,7 @@ 84 84 Assume user already input the LA66 USB LoRaWAN Adapter OTAA Keys in TTN and there is already TTN network coverage. 85 85 ))) 86 86 87 -(% style="color:blue" %)**1. 87 +(% style="color:blue" %)**1. Connect the LA66 USB LoRaWAN adapter to PC** 88 88 89 89 [[image:image-20220723100027-1.png]] 90 90 ... ... @@ -97,7 +97,7 @@ 97 97 [[image:image-20220602161718-9.png||height="457" width="800"]] 98 98 99 99 100 -(% style="color:blue" %)**2. 100 +(% style="color:blue" %)**2. Press the reset switch RST on the LA66_V1 USB LoRaWAN Adapter to reset it.(You do not need to reset the LA66 V2 USB LoRaWAN Adapter.)** 101 101 102 102 The following picture appears to prove that the LA66 USB LoRaWAN Adapter successfully Join the LoRaWAN network 103 103 ... ... @@ -104,7 +104,7 @@ 104 104 [[image:image-20220602161935-10.png||height="498" width="800"]] 105 105 106 106 107 -(% style="color:blue" %)**3. 107 +(% style="color:blue" %)**3. See Uplink Command** 108 108 109 109 Command format: (% style="color:#4472c4" %)** AT+SENDB=<confirn_status>,<Fport>,<data_len>,<data>** 110 110 ... ... @@ -113,7 +113,7 @@ 113 113 [[image:image-20220602162157-11.png||height="497" width="800"]] 114 114 115 115 116 -(% style="color:blue" %)** 4. Check to see if TTN received the message**116 +(% style="color:blue" %)**5. Check to see if TTN received the message** 117 117 118 118 [[image:image-20220817093644-1.png]] 119 119 ... ... @@ -256,7 +256,7 @@ 256 256 257 257 A USB to Type-C adapter is needed to connect to a Mobile phone. 258 258 259 -Note: The package of LA66 USB adapter already includes this USB Type-C adapter. 259 +(% style="color:red" %)**Note: The package of LA66 USB adapter already includes this USB Type-C adapter.** 260 260 261 261 [[image:image-20220813174353-2.png||height="360" width="313"]] 262 262 ... ... @@ -274,7 +274,7 @@ 274 274 275 275 Function and page introduction: 276 276 277 -[[image:image-20220723113448-7.png||height="9 95" width="450"]]277 +[[image:image-20220723113448-7.png||height="911" width="412"]] 278 278 279 279 280 280 (% style="color:blue" %)**Block Explain:** ... ... @@ -321,11 +321,9 @@ 321 321 322 322 (% style="color:blue" %)**1. Register LA66 USB LoRaWAN Module to TTNV3** 323 323 324 - 325 325 [[image:image-20220723134549-8.png]] 326 326 327 327 328 - 329 329 (% style="color:blue" %)**2. Open Node-RED,And import the JSON file to generate the flow** 330 330 331 331 ... ... @@ -345,21 +345,66 @@ 345 345 346 346 == 1.10 Upgrade Firmware of LA66 USB LoRaWAN Adapter == 347 347 348 -=== 1.10.1 LA66V1Update method ===346 +=== 1.10.1 Update method: For LA66 with bootloader === 349 349 350 -The LA66 USB LoRaWAN Adapter is the same as the LA66 LoRaWAN Shield update method. 351 351 352 - Justuse theyellowjumpercaptoshorttheBOOTcornerand theRXcorner,and thenpresstheRESETbutton (withoutthejumpercap,youcandirectlyshortthe BOOT cornerandtheX cornerithawireto achievethesameeffect).349 +* We ship the LA66 USB LoRaWAN Adapter with a boot loader by default, and the latest boot loader is V1.4. Users can download the new version of the boot loader by clicking on this [[link>>https://www.dropbox.com/scl/fo/ztlw35a9xbkomu71u31im/AFhmjtEOaipfBAFrpMCoWrI/LoRaWAN%20End%20Node/LA66%20LoRaWAN%20module/Firmware/OTA_Firmware?dl=0&rlkey=ojjcsw927eaow01dgooldq3nu&subfolder_nav_tracking=1]]. 353 353 354 - **Firmwaredownload:**351 +[[image:image-20250122110039-1.png||height="335" width="816"]] 355 355 353 +(% style="color:red" %)**Note: Upgrading the boot loader requires using the upgrade method described in section 1.10.2.** 354 + 355 + 356 +* For the bootloader V1.4, compared to V1.3, his role is to support OTA configuration for T68DL (D let Gino product model). 357 + 358 +So if your LA66 doesn't need this feature, you can also just follow the below to upgrade the firmware instead of the bootloader: 359 + 360 +**Firmware download (Please select withbootloader version):** 361 + 356 356 [[Firmware - Dropbox>>url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AABJQUWNgt61Z567OcUf-sIya/LA66%20LoRaWAN%20module/Firmware?dl=0&subfolder_nav_tracking=1]] 357 357 364 + 365 +**Firmware update method:** 366 + 367 +Please refer to this link 368 + 369 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H3.2.1UpdateafirmwareviaDraginoSensorManagerUtility.exe>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H3.2.1UpdateafirmwareviaDraginoSensorManagerUtility.exe]] 370 + 371 + 372 +=== 1.10.2 Update method: For LA66 without bootloader === 373 + 374 + 375 +* Explanation: 376 + 377 +For LA66 without a bootloader, we can only burn a bootloader for it in the following way. Because using OTA_Tool to upgrade the firmware of LA66 this address is (% style="color:blue" %)**0x0800D000**(%%) by default, but our bootloader needs to be burned at address . 378 + 379 +Therefore, you can use this method to download the firmware with the boot loader directly or upgrade your boot loader (address from (% style="color:blue" %)**0x08000000**(%%)). 380 + 381 +**Firmware download(Download firmware with bootloader):** 382 + 383 +[[Firmware - Dropbox>>url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AABJQUWNgt61Z567OcUf-sIya/LA66%20LoRaWAN%20module/Firmware?dl=0&subfolder_nav_tracking=1]] 384 + 385 +[[image:image-20250122111651-2.png||height="243" width="682"]] 386 + 387 + 388 +* Upgrade Details: 389 + 390 +The LA66 USB LoRaWAN Adapter is the same as the LA66 LoRaWAN Shield update method. 391 + 392 +Just use the yellow jumper cap to short the BOOT corner and the RX corner, and then press the RESET button (without the jumper cap, you can directly short the BOOT corner and the RX corner with a wire to achieve the same effect). 393 + 358 358 (% style="color:red" %)**Notice: If upgrade via USB hub is not sucessful. try to connect to PC directly.** 359 359 360 360 [[image:image-20220723150132-2.png||height="514" width="506"]] 361 361 362 362 399 +(% style="color:blue" %)**For the LA66 USB LoRaWAN Adapter v1.2, the hardware design has eliminated the reset button, so the first step we need to use the DuPont wire to connect the BOOT pin to the RX pin. Second, connect the LA66 USB LoRaWAN Adapter v1.2 to a USB hub or computer USB port so that it will enter burn mode. Then follow the steps below to burn the firmware.** 400 + 401 +(% style="color:red" %)**Note: After the successful burning need to unplug the LA66 USB LoRaWAN Adapter v1.2, and then reconnect the computer interface, so that it will exit the burning mode.** 402 + 403 +[[image:image-20240401171313-1.jpeg||height="521" width="792"]] 404 + 405 + 363 363 (% class="wikigeneratedid" id="HOpentheUpgradetool28TremoProgrammer29inPCandUpgrade" %) 364 364 (% style="color:blue" %)**Open the Upgrade tool (Tremo Programmer) in PC and Upgrade** 365 365 ... ... @@ -398,21 +398,7 @@ 398 398 399 399 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20LoRaWAN%20Shield%20User%20Manual/WebHome/image-20220602105251-15.png?rev=1.1||alt="image-20220602105251-15.png" height="513" width="406"]] 400 400 401 -=== 1.10.2 LA66V2 Update method === 402 402 403 - 404 -**Firmware download(Please select withbootloader version):** 405 - 406 -[[Firmware - Dropbox>>url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AABJQUWNgt61Z567OcUf-sIya/LA66%20LoRaWAN%20module/Firmware?dl=0&subfolder_nav_tracking=1]] 407 - 408 - 409 -**Firmware update method:** 410 - 411 -Please refer to this link 412 - 413 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H3.2.1UpdateafirmwareviaDraginoSensorManagerUtility.exe>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H3.2.1UpdateafirmwareviaDraginoSensorManagerUtility.exe]] 414 - 415 - 416 416 = 2. FAQ = 417 417 418 418 == 2.1 How to Compile Source Code for LA66? == ... ... @@ -447,7 +447,6 @@ 447 447 448 448 **Part Number:** (% style="color:blue" %)**LA66-USB-LoRaWAN-Adapter-XXX** 449 449 450 - 451 451 (% style="color:blue" %)**XXX**(%%): The default frequency band 452 452 453 453 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
- image-20240401171313-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +108.5 KB - Content
- image-20250122110039-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.7 KB - Content
- image-20250122111651-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.4 KB - Content