<
From version < 64.1 >
edited by David Huang
on 2022/06/21 14:25
To version < 56.1 >
edited by Edwin Chen
on 2022/06/19 08:13
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.David
1 +XWiki.Edwin
Content
... ... @@ -71,20 +71,10 @@
71 71  Change Log:
72 72  
73 73  
74 -= How to use? =
74 += Operation Mode =
75 75  
76 -== Connect to GroPoint Profile ==
76 +== How it works? ==
77 77  
78 -GroPoint Air must be used with [[GroPoint Profile>>https://www.gropoint.com/products/soil-sensors/gropoint-profile]]. There are different interface model from GroPoint, users need to choose the one:
79 -
80 -* Support RS485 Interface
81 -* with M12 5pin connector.
82 -
83 -Such model in GroPoint Profile is: **2625-N-T-x-M-M **(Where x is different depending on how many levels it detects).
84 -
85 -
86 -== Connect to LoRaWAN Network? ==
87 -
88 88  Each GroPoint Air is shipped with a worldwide unique set of OTAA keys. To use GroPoint Air in a LoRaWAN network, user needs to input the OTAA keys in the LoRaWAN network server. So GroPoint Air can join the LoRaWAN network and start to transmit sensor data
89 89  
90 90  
... ... @@ -135,50 +135,6 @@
135 135  [[https:~~/~~/www.dropbox.com/sh/4strg6w7kkekdc4/AAAUKdAV3XKhOi3t6YjA8j9za?dl=0>>https://www.dropbox.com/sh/4strg6w7kkekdc4/AAAUKdAV3XKhOi3t6YjA8j9za?dl=0]]
136 136  
137 137  
138 -== Uplink Payload Analyze ==
139 -
140 -Uplink payloads have two types:
141 -
142 -* (((
143 -Report temperature and humidity status normally: Use FPORT=2
144 -)))
145 -* (((
146 -Other control commands: Use other FPORT fields.
147 -)))
148 -
149 -The application server should parse the correct value based on FPORT settings.
150 -
151 -
152 -== temperature and humidity Value, Uplink FPORT~=2 ==
153 -
154 -
155 -GroPoint Air will send this uplink after Device Status once join the LoRaWAN network successfully. And GroPoint Air will:
156 -
157 -periodically send this uplink every 20 minutes, this interval can be changed.
158 -
159 -The drawing below shows the probe dimensions of the 2-8 segment probes, Temperature sen sor locations provided in table below:
160 -
161 -[[image:image-20220621093414-1.png||height="932" width="816"]]
162 -
163 -GroPoint Air's sensors come in six models:GPLP-2,GPLP-3,GPLP-4,GPLP-5,GPLP-6,GPLP-8.
164 -
165 -The amount of temperature and humidity is different for each model, so the payload of each model is different.
166 -
167 -Take GPLP-3 as an example:
168 -
169 -Uplink Payload totals 21 bytes.
170 -
171 -[[image:image-20220621100751-2.png||height="124" width="774"]]
172 -
173 -[[image:image-20220611174943-1.png||height="139" width="1008"]]
174 -
175 -
176 -For US915 frequency, when DR=0 and the payload length exceeds 11, the DR of this packet is switched to 1.
177 -
178 -For AU915 frequency, when DR=2,Dwelltime=1 and the payload length exceeds 11, the DR of this packet is switched to 3.
179 -
180 -For AS923 frequency, when DR=2,Dwelltime=1 and the payload length exceeds 11, the DR of this packet is switched to 3.
181 -
182 182  == Show data on Datacake ==
183 183  
184 184  Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
... ... @@ -268,8 +268,6 @@
268 268  
269 269  Feature: Change the sensor delay time.
270 270  
271 -There are six models of GroPoint Air, and each model returns a different number of temperature and humidity. The more bytes of the returned value, the longer the delay. The AT+SDELAY command can adjust the time that the sensor returns data to the node, and can adjust different delays according to different types of sensors.
272 -
273 273  The default delay is 1000ms.
274 274  
275 275  **AT Command: AT+SDELAY**
... ... @@ -285,15 +285,8 @@
285 285  * Example 1: Downlink Payload: A10003E8 ~/~/ Set the sensor delay time = 1000ms
286 286  * Example 2: Downlink Payload: A10007D0 ~/~/ Set the sensor delay time = 2000ms
287 287  
288 -== 3.4 Query sensor model function ==
232 +== 3.4 Get Firmware Version Info ==
289 289  
290 -Feature: Using this function will re-update the model.
291 -
292 -**Downlink Command: 0xFA00**
293 -
294 -
295 -== 3.5 Get Firmware Version Info ==
296 -
297 297  Feature: use downlink to get firmware version.
298 298  
299 299  **Downlink Command: 0x26**
... ... @@ -480,9 +480,7 @@
480 480  
481 481  In case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while pressing the send key, user need to add ENTER in their string.
482 482  
483 -== Why i see the payload is 7FFF? ==
484 484  
485 -The device will judge the length of the data received by the serial port. If the length of the received data is 0, it means that there is a problem with the sensor communication or the sensor is not connected properly, it is invalid data, and the uploaded data is 7FFF.
486 486  
487 487  = Order Info =
488 488  
image-20220621093414-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.David
Size
... ... @@ -1,1 +1,0 @@
1 -158.4 KB
Content
image-20220621100751-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.David
Size
... ... @@ -1,1 +1,0 @@
1 -6.7 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0