From version < 61.1 >
edited by David Huang
on 2022/06/21 10:26
To version < 64.1 >
edited by David Huang
on 2022/06/21 14:25
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -173,6 +173,12 @@
173 173  [[image:image-20220611174943-1.png||height="139" width="1008"]]
174 174  
175 175  
176 +For US915 frequency, when DR=0 and the payload length exceeds 11, the DR of this packet is switched to 1.
177 +
178 +For AU915 frequency, when DR=2,Dwelltime=1 and the payload length exceeds 11, the DR of this packet is switched to 3.
179 +
180 +For AS923 frequency, when DR=2,Dwelltime=1 and the payload length exceeds 11, the DR of this packet is switched to 3.
181 +
176 176  == Show data on Datacake ==
177 177  
178 178  Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
... ... @@ -262,6 +262,8 @@
262 262  
263 263  Feature: Change the sensor delay time.
264 264  
271 +There are six models of GroPoint Air, and each model returns a different number of temperature and humidity. The more bytes of the returned value, the longer the delay. The AT+SDELAY command can adjust the time that the sensor returns data to the node, and can adjust different delays according to different types of sensors.
272 +
265 265  The default delay is 1000ms.
266 266  
267 267  **AT Command: AT+SDELAY**
... ... @@ -277,8 +277,15 @@
277 277  * Example 1: Downlink Payload: A10003E8 ~/~/ Set the sensor delay time = 1000ms
278 278  * Example 2: Downlink Payload: A10007D0 ~/~/ Set the sensor delay time = 2000ms
279 279  
280 -== 3.4 Get Firmware Version Info ==
288 +== 3.4 Query sensor model function ==
281 281  
290 +Feature: Using this function will re-update the model.
291 +
292 +**Downlink Command: 0xFA00**
293 +
294 +
295 +== 3.5 Get Firmware Version Info ==
296 +
282 282  Feature: use downlink to get firmware version.
283 283  
284 284  **Downlink Command: 0x26**
... ... @@ -465,7 +465,9 @@
465 465  
466 466  In case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while pressing the send key, user need to add ENTER in their string.
467 467  
483 +== Why i see the payload is 7FFF? ==
468 468  
485 +The device will judge the length of the data received by the serial port. If the length of the received data is 0, it means that there is a problem with the sensor communication or the sensor is not connected properly, it is invalid data, and the uploaded data is 7FFF.
469 469  
470 470  = Order Info =
471 471  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0