Last modified by Xiaoling on 2025/04/25 10:03
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -173,6 +173,10 @@ 173 173 [[image:image-20220611174943-1.png||height="139" width="1008"]] 174 174 175 175 176 +For US915 frequency, when DR=0 and the payload length exceeds 11, the DR of this packet is switched to 1. 177 + 178 +For AU915 frequency, when DR=0 and the payload length exceeds 11, the DR of this packet is switched to 3. 179 + 176 176 == Show data on Datacake == 177 177 178 178 Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: ... ... @@ -262,6 +262,8 @@ 262 262 263 263 Feature: Change the sensor delay time. 264 264 269 +There are six models of GroPoint Air, and each model returns a different number of temperature and humidity. The more bytes of the returned value, the longer the delay. The AT+SDELAY command can adjust the time that the sensor returns data to the node, and can adjust different delays according to different types of sensors. 270 + 265 265 The default delay is 1000ms. 266 266 267 267 **AT Command: AT+SDELAY** ... ... @@ -277,8 +277,15 @@ 277 277 * Example 1: Downlink Payload: A10003E8 ~/~/ Set the sensor delay time = 1000ms 278 278 * Example 2: Downlink Payload: A10007D0 ~/~/ Set the sensor delay time = 2000ms 279 279 280 -== 3.4 GetFirmwareVersionInfo==286 +== 3.4 Query sensor model function == 281 281 288 +Feature: Using this function will re-update the model. 289 + 290 +**Downlink Command: 0xFA00** 291 + 292 + 293 +== 3.5 Get Firmware Version Info == 294 + 282 282 Feature: use downlink to get firmware version. 283 283 284 284 **Downlink Command: 0x26** ... ... @@ -465,7 +465,9 @@ 465 465 466 466 In case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while pressing the send key, user need to add ENTER in their string. 467 467 481 +== Why i see the payload is 7FFF? == 468 468 483 +The device will judge the length of the data received by the serial port. If the length of the received data is 0, it means that there is a problem with the sensor communication or the sensor is not connected properly, it is invalid data, and the uploaded data is 7FFF. 469 469 470 470 = Order Info = 471 471