... ... @@ -210,8 +210,27 @@
210 210  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
211 211  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
212 212  
213 -== 3.3 Get Firmware Version Info ==
213 +== (% id="cke_bm_55968S" style="display:none" %) (%%)3.3 Set the sensor delay time ==
214 214  
215 +Feature: Change the sensor delay time.
216 +
217 +The default delay is 1000ms.
218 +
219 +**AT Command: AT+SDELAY**
220 +
221 +[[image:image-20220613175511-8.png]]
222 +
223 +**Downlink Command: 0xA1**
224 +
225 +Format: Command Code (0xA1) followed by 3 bytes time value.
226 +
227 +If the downlink payload=A10007D0, it means set the sensor delay time to 0x0007D0=2000ms, while type code is A1.
228 +
229 +* Example 1: Downlink Payload: A10003E8 ~/~/ Set the sensor delay time = 1000ms
230 +* Example 2: Downlink Payload: A10007D0 ~/~/ Set the sensor delay time = 2000ms
231 +
232 +== 3.4 Get Firmware Version Info ==
233 +
215 215  Feature: use downlink to get firmware version.
216 216  
217 217  **Downlink Command: 0x26**
... ... @@ -427,4 +427,3 @@
427 427  * Device Weight: g
428 428  * Package Size / pcs : cm
429 429  * Weight / pcs : g