Last modified by Xiaoling on 2025/04/25 10:03
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. David1 +XWiki.Edwin - Content
-
... ... @@ -54,24 +54,6 @@ 54 54 [[image:image-20220530002453-3.png||height="262" width="493"]] 55 55 56 56 57 -= Connect LoRaWAN Network = 58 - 59 - 60 -== LED Indicator == 61 - 62 -The GroPoint Air has an internal LED which can show the status of different states. 63 - 64 -* The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. 65 -* Blink once when device transmits a packet. 66 - 67 -== Firmware and Changelog == 68 - 69 -Firmware Download Location: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/GroPoint_Air/firmware/>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/GroPoint_Air/firmware/]] 70 - 71 -Change Log: 72 - 73 - 74 - 75 75 = Configure GroPoint Air via AT Command or LoRaWAN Downlink = 76 76 77 77 Use can configure GroPoint Air via AT Command or LoRaWAN Downlink. ... ... @@ -87,8 +87,12 @@ 87 87 88 88 These commands are to configure: 89 89 90 -* General system settings like: uplink interval. 91 -* LoRaWAN protocol & radio-related command. 72 +* ((( 73 +General system settings like: uplink interval. 74 +))) 75 +* ((( 76 +LoRaWAN protocol & radio-related command. 77 +))) 92 92 93 93 They are the same for all Dragino Device that support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>url:http://8.211.40.43/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 94 94 ... ... @@ -113,11 +113,17 @@ 113 113 114 114 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 115 115 116 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 117 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 102 +* ((( 103 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 104 +))) 105 +* ((( 106 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 118 118 119 -== 3.2 Set Interrupt Mode == 108 + 109 +))) 120 120 111 +== 3.2 Set Interrupt Mode (是否存在) == 112 + 121 121 Feature, Set Interrupt mode for GPIO_EXIT. 122 122 123 123 **AT Command: AT+INTMOD** ... ... @@ -130,10 +130,14 @@ 130 130 131 131 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 132 132 133 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 134 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 125 +* ((( 126 +Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 127 +))) 128 +* ((( 129 +Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 130 +))) 135 135 136 -== 3.3 Get Firmware Version Info == 132 +== 3.3 Get Firmware Version Info ~-~--(是否存在) == 137 137 138 138 Feature: use downlink to get firmware version. 139 139 ... ... @@ -150,7 +150,7 @@ 150 150 151 151 |=((( 152 152 **Size(bytes)** 153 -)))|=**1**|=**1**|=**1**|=** 2**|=**1**|=4|=**1**149 +)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1** 154 154 |**Value**|Software Type|((( 155 155 Frequency 156 156 ... ... @@ -186,10 +186,8 @@ 186 186 187 187 *0x09: AS923-2 188 188 189 -*0x0 A: AS923-3185 +*0xa0: AS923-3 190 190 191 -*0x0B: AS923-4 192 - 193 193 **Sub-Band**: value 0x00 ~~ 0x08 194 194 195 195 **Firmware Version**: 0x0100, Means: v1.0.0 version ... ... @@ -208,9 +208,7 @@ 208 208 209 209 0x06: LSNPK01 210 210 211 -0x07: LDDS45 212 212 213 -0x08: LSLP01 214 214 215 215 = Use AT Command = 216 216