From version < 38.1 >
edited by Edwin Chen
on 2022/06/09 00:00
To version < 32.1 >
edited by Edwin Chen
on 2022/06/08 23:52
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -54,31 +54,18 @@
54 54  [[image:image-20220530002453-3.png||height="262" width="493"]]
55 55  
56 56  
57 -== LED Indicator  ( 检查等状态是否对的) ==
58 -
59 -The GroPoint Air has an internal LED which can show the status of different states.
60 -
61 -* The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
62 -* Blink once when device transmits a packet.
63 -
64 -
65 -
66 -== Firmware and Changelog (Changelog标注现在 版本是什么版本) ==
67 -
68 -Firmware Download Location: [[https:~~/~~/www.dropbox.com/sh/4strg6w7kkekdc4/AAAUKdAV3XKhOi3t6YjA8j9za?dl=0>>https://www.dropbox.com/sh/4strg6w7kkekdc4/AAAUKdAV3XKhOi3t6YjA8j9za?dl=0]]
69 -
70 -Change Log:
71 -
72 -
73 -
74 74  = Configure GroPoint Air via AT Command or LoRaWAN Downlink =
75 75  
76 76  Use can configure GroPoint Air via AT Command or LoRaWAN Downlink.
77 77  
78 -* AT Command Connection: See [[FAQ>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H6.FAQ]].
79 -* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>url:http://8.211.40.43/xwiki/bin/view/Main/]]
61 +* (((
62 +AT Command Connection: See [[FAQ>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H6.FAQ]].
63 +)))
64 +* (((
65 +LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>url:http://8.211.40.43/xwiki/bin/view/Main/]]
66 +)))
80 80  
81 -There are two kinds of commands to configure GroPoint Air, they are:
68 +There are two kinds of commands to configure GroPoint, they are:
82 82  
83 83  * (((
84 84  **~ General Commands**.
... ... @@ -86,17 +86,21 @@
86 86  
87 87  These commands are to configure:
88 88  
89 -* General system settings like: uplink interval.
90 -* LoRaWAN protocol & radio-related command.
76 +* (((
77 +General system settings like: uplink interval.
78 +)))
79 +* (((
80 +LoRaWAN protocol & radio-related command.
81 +)))
91 91  
92 92  They are the same for all Dragino Device that support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>url:http://8.211.40.43/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
93 93  
94 94  
95 95  * (((
96 -**~ Commands special design for GroPoint Air**
87 +**~ Commands special design for LLMS01**
97 97  )))
98 98  
99 -These commands only valid for GroPoint Air, as below:
90 +These commands only valid for LLMS01, as below:
100 100  
101 101  == 3.1 Set Transmit Interval Time ==
102 102  
... ... @@ -112,9 +112,15 @@
112 112  
113 113  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
114 114  
115 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
116 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
106 +* (((
107 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
108 +)))
109 +* (((
110 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
117 117  
112 +
113 +)))
114 +
118 118  == 3.2 Set Interrupt Mode  (是否存在) ==
119 119  
120 120  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -129,9 +129,14 @@
129 129  
130 130  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
131 131  
132 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
133 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
129 +* (((
130 +Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
131 +)))
132 +* (((
133 +Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
134 +)))
134 134  
136 +
135 135  == 3.3 Get Firmware Version Info ~-~--(是否存在) ==
136 136  
137 137  Feature: use downlink to get firmware version.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0