... ... @@ -54,144 +54,6 @@
54 54  [[image:image-20220530002453-3.png||height="262" width="493"]]
55 55  
56 56  
57 -= Configure GroPoint Air via AT Command or LoRaWAN Downlink =
58 -
59 -Use can configure GroPoint Air via AT Command or LoRaWAN Downlink.
60 -
61 -* AT Command Connection: See [[FAQ>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H6.FAQ]].
62 -* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>url:http://8.211.40.43/xwiki/bin/view/Main/]]
63 -
64 -There are two kinds of commands to configure GroPoint Air, they are:
65 -
66 -* (((
67 -**~ General Commands**.
68 -)))
69 -
70 -These commands are to configure:
71 -
72 -* General system settings like: uplink interval.
73 -* LoRaWAN protocol & radio-related command.
74 -
75 -They are the same for all Dragino Device that support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>url:http://8.211.40.43/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
76 -
77 -
78 -* (((
79 -**~ Commands special design for GroPoint Air**
80 -)))
81 -
82 -These commands only valid for GroPoint Air, as below:
83 -
84 -== 3.1 Set Transmit Interval Time ==
85 -
86 -Feature: Change LoRaWAN End Node Transmit Interval.
87 -
88 -**AT Command: AT+TDC**
89 -
90 -[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171554-8.png?rev=1.1||alt="image-20220607171554-8.png"]]
91 -
92 -**Downlink Command: 0x01**
93 -
94 -Format: Command Code (0x01) followed by 3 bytes time value.
95 -
96 -If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
97 -
98 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
99 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
100 -
101 -
102 -== 3.2 Set Interrupt Mode  (是否存在) ==
103 -
104 -Feature, Set Interrupt mode for GPIO_EXIT.
105 -
106 -**AT Command: AT+INTMOD**
107 -
108 -[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171716-9.png?rev=1.1||alt="image-20220607171716-9.png"]]
109 -
110 -**Downlink Command: 0x06**
111 -
112 -Format: Command Code (0x06) followed by 3 bytes.
113 -
114 -This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
115 -
116 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
117 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
118 -
119 -
120 -== 3.3 Get Firmware Version Info ~-~--(是否存在) ==
121 -
122 -Feature: use downlink to get firmware version.
123 -
124 -**Downlink Command: 0x26**
125 -
126 -[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171917-10.png?rev=1.1||alt="image-20220607171917-10.png"]]
127 -
128 -* Reply to the confirmation package: 26 01
129 -* Reply to non-confirmed packet: 26 00
130 -
131 -Device will send an uplink after got this downlink command. With below payload:
132 -
133 -Configures info payload:
134 -
135 -|=(((
136 -**Size(bytes)**
137 -)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
138 -|**Value**|Software Type|(((
139 -Frequency
140 -
141 -Band
142 -)))|Sub-band|(((
143 -Firmware
144 -
145 -Version
146 -)))|Sensor Type|Reserve|(((
147 -[[Message Type>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H2.3.6MessageType]]
148 -Always 0x02
149 -)))
150 -
151 -**Software Type**: Always 0x03 for LLMS01
152 -
153 -**Frequency Band**:
154 -
155 -*0x01: EU868
156 -
157 -*0x02: US915
158 -
159 -*0x03: IN865
160 -
161 -*0x04: AU915
162 -
163 -*0x05: KZ865
164 -
165 -*0x06: RU864
166 -
167 -*0x07: AS923
168 -
169 -*0x08: AS923-1
170 -
171 -*0x09: AS923-2
172 -
173 -*0xa0: AS923-3
174 -
175 -**Sub-Band**: value 0x00 ~~ 0x08
176 -
177 -**Firmware Version**: 0x0100, Means: v1.0.0 version
178 -
179 -**Sensor Type**:
180 -
181 -0x01: LSE01
182 -
183 -0x02: LDDS75
184 -
185 -0x03: LDDS20
186 -
187 -0x04: LLMS01
188 -
189 -0x05: LSPH01
190 -
191 -0x06: LSNPK01
192 -
193 -
194 -
195 195  = Use AT Command =
196 196  
197 197  == Access AT Commands ==
... ... @@ -231,6 +231,7 @@
231 231  
232 232  GroPoint Air:  2.45v ~~ 3.6v
233 233  
96 +== ==
234 234  
235 235  == Power Consumption Analyze ==
236 236  
... ... @@ -254,7 +254,7 @@
254 254  Working Mode
255 255  )))
256 256  
257 -And the Life expectation in different cases will be shown on the right.
120 +And the Life expectation in difference case will be shown on the right.
258 258  
259 259  [[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/1654593605679-189.png?rev=1.1||alt="1654593605679-189.png"]]
260 260  
... ... @@ -272,11 +272,13 @@
272 272  
273 273  [[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607172042-11.png?rev=1.1||alt="image-20220607172042-11.png"]]
274 274  
138 +=== ===
275 275  
276 276  === ​Battery Note ===
277 277  
278 278  The Li-SICO battery is designed for small current / long period applications. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period to transmit LoRa, then the battery life may be decreased.
279 279  
144 +=== ===
280 280  
281 281  === Replace the battery ===