From version < 30.1 >
edited by Edwin Chen
on 2022/06/08 23:48
To version < 35.1 >
edited by Edwin Chen
on 2022/06/08 23:55
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -54,6 +54,144 @@
54 54  [[image:image-20220530002453-3.png||height="262" width="493"]]
55 55  
56 56  
57 += Configure GroPoint Air via AT Command or LoRaWAN Downlink =
58 +
59 +Use can configure GroPoint Air via AT Command or LoRaWAN Downlink.
60 +
61 +* AT Command Connection: See [[FAQ>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H6.FAQ]].
62 +* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>url:http://8.211.40.43/xwiki/bin/view/Main/]]
63 +
64 +There are two kinds of commands to configure GroPoint Air, they are:
65 +
66 +* (((
67 +**~ General Commands**.
68 +)))
69 +
70 +These commands are to configure:
71 +
72 +* General system settings like: uplink interval.
73 +* LoRaWAN protocol & radio-related command.
74 +
75 +They are the same for all Dragino Device that support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>url:http://8.211.40.43/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
76 +
77 +
78 +* (((
79 +**~ Commands special design for GroPoint Air**
80 +)))
81 +
82 +These commands only valid for GroPoint Air, as below:
83 +
84 +== 3.1 Set Transmit Interval Time ==
85 +
86 +Feature: Change LoRaWAN End Node Transmit Interval.
87 +
88 +**AT Command: AT+TDC**
89 +
90 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171554-8.png?rev=1.1||alt="image-20220607171554-8.png"]]
91 +
92 +**Downlink Command: 0x01**
93 +
94 +Format: Command Code (0x01) followed by 3 bytes time value.
95 +
96 +If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
97 +
98 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
99 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
100 +
101 +
102 +== 3.2 Set Interrupt Mode  (是否存在) ==
103 +
104 +Feature, Set Interrupt mode for GPIO_EXIT.
105 +
106 +**AT Command: AT+INTMOD**
107 +
108 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171716-9.png?rev=1.1||alt="image-20220607171716-9.png"]]
109 +
110 +**Downlink Command: 0x06**
111 +
112 +Format: Command Code (0x06) followed by 3 bytes.
113 +
114 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
115 +
116 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
117 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
118 +
119 +
120 +== 3.3 Get Firmware Version Info ~-~--(是否存在) ==
121 +
122 +Feature: use downlink to get firmware version.
123 +
124 +**Downlink Command: 0x26**
125 +
126 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171917-10.png?rev=1.1||alt="image-20220607171917-10.png"]]
127 +
128 +* Reply to the confirmation package: 26 01
129 +* Reply to non-confirmed packet: 26 00
130 +
131 +Device will send an uplink after got this downlink command. With below payload:
132 +
133 +Configures info payload:
134 +
135 +|=(((
136 +**Size(bytes)**
137 +)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
138 +|**Value**|Software Type|(((
139 +Frequency
140 +
141 +Band
142 +)))|Sub-band|(((
143 +Firmware
144 +
145 +Version
146 +)))|Sensor Type|Reserve|(((
147 +[[Message Type>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H2.3.6MessageType]]
148 +Always 0x02
149 +)))
150 +
151 +**Software Type**: Always 0x03 for LLMS01
152 +
153 +**Frequency Band**:
154 +
155 +*0x01: EU868
156 +
157 +*0x02: US915
158 +
159 +*0x03: IN865
160 +
161 +*0x04: AU915
162 +
163 +*0x05: KZ865
164 +
165 +*0x06: RU864
166 +
167 +*0x07: AS923
168 +
169 +*0x08: AS923-1
170 +
171 +*0x09: AS923-2
172 +
173 +*0xa0: AS923-3
174 +
175 +**Sub-Band**: value 0x00 ~~ 0x08
176 +
177 +**Firmware Version**: 0x0100, Means: v1.0.0 version
178 +
179 +**Sensor Type**:
180 +
181 +0x01: LSE01
182 +
183 +0x02: LDDS75
184 +
185 +0x03: LDDS20
186 +
187 +0x04: LLMS01
188 +
189 +0x05: LSPH01
190 +
191 +0x06: LSNPK01
192 +
193 +
194 +
57 57  = Use AT Command =
58 58  
59 59  == Access AT Commands ==
... ... @@ -93,7 +93,6 @@
93 93  
94 94  GroPoint Air:  2.45v ~~ 3.6v
95 95  
96 -== ==
97 97  
98 98  == Power Consumption Analyze ==
99 99  
... ... @@ -117,7 +117,7 @@
117 117  Working Mode
118 118  )))
119 119  
120 -And the Life expectation in difference case will be shown on the right.
257 +And the Life expectation in different cases will be shown on the right.
121 121  
122 122  [[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/1654593605679-189.png?rev=1.1||alt="1654593605679-189.png"]]
123 123  
... ... @@ -135,13 +135,11 @@
135 135  
136 136  [[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607172042-11.png?rev=1.1||alt="image-20220607172042-11.png"]]
137 137  
138 -=== ===
139 139  
140 140  === ​Battery Note ===
141 141  
142 142  The Li-SICO battery is designed for small current / long period applications. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period to transmit LoRa, then the battery life may be decreased.
143 143  
144 -=== ===
145 145  
146 146  === Replace the battery ===
147 147  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0