Last modified by Xiaoling on 2024/04/23 14:37
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -54,6 +54,159 @@ 54 54 [[image:image-20220530002453-3.png||height="262" width="493"]] 55 55 56 56 57 +== LED Indicator ( 检查等状态是否对的) == 58 + 59 +The GroPoint Air has an internal LED which can show the status of different states. 60 + 61 +* The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. 62 +* Blink once when device transmits a packet. 63 + 64 + 65 + 66 +== Firmware and Changelog (Changelog标注现在 版本是什么版本) == 67 + 68 +Firmware Download Location: [[https:~~/~~/www.dropbox.com/sh/4strg6w7kkekdc4/AAAUKdAV3XKhOi3t6YjA8j9za?dl=0>>https://www.dropbox.com/sh/4strg6w7kkekdc4/AAAUKdAV3XKhOi3t6YjA8j9za?dl=0]] 69 + 70 +Change Log: 71 + 72 + 73 + 74 += Configure GroPoint Air via AT Command or LoRaWAN Downlink = 75 + 76 +Use can configure GroPoint Air via AT Command or LoRaWAN Downlink. 77 + 78 +* AT Command Connection: See [[FAQ>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H6.FAQ]]. 79 +* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>url:http://8.211.40.43/xwiki/bin/view/Main/]] 80 + 81 +There are two kinds of commands to configure GroPoint Air, they are: 82 + 83 +* ((( 84 +**~ General Commands**. 85 +))) 86 + 87 +These commands are to configure: 88 + 89 +* General system settings like: uplink interval. 90 +* LoRaWAN protocol & radio-related command. 91 + 92 +They are the same for all Dragino Device that support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>url:http://8.211.40.43/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 93 + 94 + 95 +* ((( 96 +**~ Commands special design for GroPoint Air** 97 +))) 98 + 99 +These commands only valid for GroPoint Air, as below: 100 + 101 +== 3.1 Set Transmit Interval Time == 102 + 103 +Feature: Change LoRaWAN End Node Transmit Interval. 104 + 105 +**AT Command: AT+TDC** 106 + 107 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171554-8.png?rev=1.1||alt="image-20220607171554-8.png"]] 108 + 109 +**Downlink Command: 0x01** 110 + 111 +Format: Command Code (0x01) followed by 3 bytes time value. 112 + 113 +If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 114 + 115 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 116 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 117 + 118 +== 3.2 Set Interrupt Mode (是否存在) == 119 + 120 +Feature, Set Interrupt mode for GPIO_EXIT. 121 + 122 +**AT Command: AT+INTMOD** 123 + 124 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171716-9.png?rev=1.1||alt="image-20220607171716-9.png"]] 125 + 126 +**Downlink Command: 0x06** 127 + 128 +Format: Command Code (0x06) followed by 3 bytes. 129 + 130 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 131 + 132 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 133 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 134 + 135 +== 3.3 Get Firmware Version Info ~-~--(是否存在) == 136 + 137 +Feature: use downlink to get firmware version. 138 + 139 +**Downlink Command: 0x26** 140 + 141 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171917-10.png?rev=1.1||alt="image-20220607171917-10.png"]] 142 + 143 +* Reply to the confirmation package: 26 01 144 +* Reply to non-confirmed packet: 26 00 145 + 146 +Device will send an uplink after got this downlink command. With below payload: 147 + 148 +Configures info payload: 149 + 150 +|=((( 151 +**Size(bytes)** 152 +)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1** 153 +|**Value**|Software Type|((( 154 +Frequency 155 + 156 +Band 157 +)))|Sub-band|((( 158 +Firmware 159 + 160 +Version 161 +)))|Sensor Type|Reserve|((( 162 +[[Message Type>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H2.3.6MessageType]] 163 +Always 0x02 164 +))) 165 + 166 +**Software Type**: Always 0x03 for LLMS01 167 + 168 +**Frequency Band**: 169 + 170 +*0x01: EU868 171 + 172 +*0x02: US915 173 + 174 +*0x03: IN865 175 + 176 +*0x04: AU915 177 + 178 +*0x05: KZ865 179 + 180 +*0x06: RU864 181 + 182 +*0x07: AS923 183 + 184 +*0x08: AS923-1 185 + 186 +*0x09: AS923-2 187 + 188 +*0xa0: AS923-3 189 + 190 +**Sub-Band**: value 0x00 ~~ 0x08 191 + 192 +**Firmware Version**: 0x0100, Means: v1.0.0 version 193 + 194 +**Sensor Type**: 195 + 196 +0x01: LSE01 197 + 198 +0x02: LDDS75 199 + 200 +0x03: LDDS20 201 + 202 +0x04: LLMS01 203 + 204 +0x05: LSPH01 205 + 206 +0x06: LSNPK01 207 + 208 + 209 + 57 57 = Use AT Command = 58 58 59 59 == Access AT Commands == ... ... @@ -93,7 +93,6 @@ 93 93 94 94 GroPoint Air: 2.45v ~~ 3.6v 95 95 96 -== == 97 97 98 98 == Power Consumption Analyze == 99 99 ... ... @@ -117,7 +117,7 @@ 117 117 Working Mode 118 118 ))) 119 119 120 -And the Life expectation in differen cecase will be shown on the right.272 +And the Life expectation in different cases will be shown on the right. 121 121 122 122 [[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/1654593605679-189.png?rev=1.1||alt="1654593605679-189.png"]] 123 123 ... ... @@ -135,26 +135,21 @@ 135 135 136 136 [[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607172042-11.png?rev=1.1||alt="image-20220607172042-11.png"]] 137 137 138 -(% class="wikigeneratedid" %) 139 -=== === 140 140 141 141 === Battery Note === 142 142 143 -The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period t ime to transmit LoRa, then the battery life may be decreased.293 +The Li-SICO battery is designed for small current / long period applications. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period to transmit LoRa, then the battery life may be decreased. 144 144 145 -(% class="wikigeneratedid" %) 146 -=== === 147 147 148 148 === Replace the battery === 149 149 150 -You can change the battery in t heLLMS01.The type of battery is not limited as long as the output is between 3v to 3.6v.On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.298 +You can change the battery in GroPoint Air. The type of battery is not limited as long as the output is between 3v to 3.6v. 151 151 152 -The default battery pack of LLMS01includes a ER26500 plus super300 +The default battery pack of GroPoint Air includes a ER26500 plus supercapacitor. If users can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most cases. The SPC can enlarge the battery life for high-frequency use (update period below 5 minutes) 153 153 154 154 155 155 156 156 157 - 158 158 = FAQ = 159 159 160 160 == How to change the LoRa Frequency Bands/Region ==