From version < 29.1 >
edited by Edwin Chen
on 2022/06/08 23:46
To version < 38.1 >
edited by Edwin Chen
on 2022/06/09 00:00
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -54,6 +54,159 @@
54 54  [[image:image-20220530002453-3.png||height="262" width="493"]]
55 55  
56 56  
57 +== LED Indicator  ( 检查等状态是否对的) ==
58 +
59 +The GroPoint Air has an internal LED which can show the status of different states.
60 +
61 +* The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
62 +* Blink once when device transmits a packet.
63 +
64 +
65 +
66 +== Firmware and Changelog (Changelog标注现在 版本是什么版本) ==
67 +
68 +Firmware Download Location: [[https:~~/~~/www.dropbox.com/sh/4strg6w7kkekdc4/AAAUKdAV3XKhOi3t6YjA8j9za?dl=0>>https://www.dropbox.com/sh/4strg6w7kkekdc4/AAAUKdAV3XKhOi3t6YjA8j9za?dl=0]]
69 +
70 +Change Log:
71 +
72 +
73 +
74 += Configure GroPoint Air via AT Command or LoRaWAN Downlink =
75 +
76 +Use can configure GroPoint Air via AT Command or LoRaWAN Downlink.
77 +
78 +* AT Command Connection: See [[FAQ>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H6.FAQ]].
79 +* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>url:http://8.211.40.43/xwiki/bin/view/Main/]]
80 +
81 +There are two kinds of commands to configure GroPoint Air, they are:
82 +
83 +* (((
84 +**~ General Commands**.
85 +)))
86 +
87 +These commands are to configure:
88 +
89 +* General system settings like: uplink interval.
90 +* LoRaWAN protocol & radio-related command.
91 +
92 +They are the same for all Dragino Device that support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>url:http://8.211.40.43/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
93 +
94 +
95 +* (((
96 +**~ Commands special design for GroPoint Air**
97 +)))
98 +
99 +These commands only valid for GroPoint Air, as below:
100 +
101 +== 3.1 Set Transmit Interval Time ==
102 +
103 +Feature: Change LoRaWAN End Node Transmit Interval.
104 +
105 +**AT Command: AT+TDC**
106 +
107 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171554-8.png?rev=1.1||alt="image-20220607171554-8.png"]]
108 +
109 +**Downlink Command: 0x01**
110 +
111 +Format: Command Code (0x01) followed by 3 bytes time value.
112 +
113 +If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
114 +
115 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
116 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
117 +
118 +== 3.2 Set Interrupt Mode  (是否存在) ==
119 +
120 +Feature, Set Interrupt mode for GPIO_EXIT.
121 +
122 +**AT Command: AT+INTMOD**
123 +
124 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171716-9.png?rev=1.1||alt="image-20220607171716-9.png"]]
125 +
126 +**Downlink Command: 0x06**
127 +
128 +Format: Command Code (0x06) followed by 3 bytes.
129 +
130 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
131 +
132 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
133 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
134 +
135 +== 3.3 Get Firmware Version Info ~-~--(是否存在) ==
136 +
137 +Feature: use downlink to get firmware version.
138 +
139 +**Downlink Command: 0x26**
140 +
141 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171917-10.png?rev=1.1||alt="image-20220607171917-10.png"]]
142 +
143 +* Reply to the confirmation package: 26 01
144 +* Reply to non-confirmed packet: 26 00
145 +
146 +Device will send an uplink after got this downlink command. With below payload:
147 +
148 +Configures info payload:
149 +
150 +|=(((
151 +**Size(bytes)**
152 +)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
153 +|**Value**|Software Type|(((
154 +Frequency
155 +
156 +Band
157 +)))|Sub-band|(((
158 +Firmware
159 +
160 +Version
161 +)))|Sensor Type|Reserve|(((
162 +[[Message Type>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H2.3.6MessageType]]
163 +Always 0x02
164 +)))
165 +
166 +**Software Type**: Always 0x03 for LLMS01
167 +
168 +**Frequency Band**:
169 +
170 +*0x01: EU868
171 +
172 +*0x02: US915
173 +
174 +*0x03: IN865
175 +
176 +*0x04: AU915
177 +
178 +*0x05: KZ865
179 +
180 +*0x06: RU864
181 +
182 +*0x07: AS923
183 +
184 +*0x08: AS923-1
185 +
186 +*0x09: AS923-2
187 +
188 +*0xa0: AS923-3
189 +
190 +**Sub-Band**: value 0x00 ~~ 0x08
191 +
192 +**Firmware Version**: 0x0100, Means: v1.0.0 version
193 +
194 +**Sensor Type**:
195 +
196 +0x01: LSE01
197 +
198 +0x02: LDDS75
199 +
200 +0x03: LDDS20
201 +
202 +0x04: LLMS01
203 +
204 +0x05: LSPH01
205 +
206 +0x06: LSNPK01
207 +
208 +
209 +
57 57  = Use AT Command =
58 58  
59 59  == Access AT Commands ==
... ... @@ -93,7 +93,6 @@
93 93  
94 94  GroPoint Air:  2.45v ~~ 3.6v
95 95  
96 -== ==
97 97  
98 98  == Power Consumption Analyze ==
99 99  
... ... @@ -117,7 +117,7 @@
117 117  Working Mode
118 118  )))
119 119  
120 -And the Life expectation in difference case will be shown on the right.
272 +And the Life expectation in different cases will be shown on the right.
121 121  
122 122  [[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/1654593605679-189.png?rev=1.1||alt="1654593605679-189.png"]]
123 123  
... ... @@ -135,26 +135,21 @@
135 135  
136 136  [[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607172042-11.png?rev=1.1||alt="image-20220607172042-11.png"]]
137 137  
138 -(% class="wikigeneratedid" %)
139 -=== ===
140 140  
141 141  === ​Battery Note ===
142 142  
143 -The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
293 +The Li-SICO battery is designed for small current / long period applications. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period to transmit LoRa, then the battery life may be decreased.
144 144  
145 -(% class="wikigeneratedid" %)
146 -=== ===
147 147  
148 148  === Replace the battery ===
149 149  
150 -You can change the battery in the LLMS01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
298 +You can change the battery in GroPoint Air. The type of battery is not limited as long as the output is between 3v to 3.6v.
151 151  
152 -The default battery pack of LLMS01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
300 +The default battery pack of GroPoint Air includes a ER26500 plus supercapacitor. If users can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most cases. The SPC can enlarge the battery life for high-frequency use (update period below 5 minutes)
153 153  
154 154  
155 155  
156 156  
157 -
158 158  = FAQ =
159 159  
160 160  == How to change the LoRa Frequency Bands/Region ==
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0