Last modified by Xiaoling on 2025/04/25 10:03
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -54,6 +54,156 @@ 54 54 [[image:image-20220530002453-3.png||height="262" width="493"]] 55 55 56 56 57 += Configure GroPoint Air via AT Command or LoRaWAN Downlink = 58 + 59 +Use can configure GroPoint Air via AT Command or LoRaWAN Downlink. 60 + 61 +* AT Command Connection: See [[FAQ>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H6.FAQ]]. 62 +* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>url:http://8.211.40.43/xwiki/bin/view/Main/]] 63 + 64 +There are two kinds of commands to configure GroPoint, they are: 65 + 66 +* ((( 67 +**~ General Commands**. 68 +))) 69 + 70 +These commands are to configure: 71 + 72 +* ((( 73 +General system settings like: uplink interval. 74 +))) 75 +* ((( 76 +LoRaWAN protocol & radio-related command. 77 +))) 78 + 79 +They are the same for all Dragino Device that support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>url:http://8.211.40.43/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 80 + 81 + 82 +* ((( 83 +**~ Commands special design for LLMS01** 84 +))) 85 + 86 +These commands only valid for LLMS01, as below: 87 + 88 +== 3.1 Set Transmit Interval Time == 89 + 90 +Feature: Change LoRaWAN End Node Transmit Interval. 91 + 92 +**AT Command: AT+TDC** 93 + 94 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171554-8.png?rev=1.1||alt="image-20220607171554-8.png"]] 95 + 96 +**Downlink Command: 0x01** 97 + 98 +Format: Command Code (0x01) followed by 3 bytes time value. 99 + 100 +If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 101 + 102 +* ((( 103 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 104 +))) 105 +* ((( 106 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 107 + 108 + 109 +))) 110 + 111 +== 3.2 Set Interrupt Mode (是否存在) == 112 + 113 +Feature, Set Interrupt mode for GPIO_EXIT. 114 + 115 +**AT Command: AT+INTMOD** 116 + 117 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171716-9.png?rev=1.1||alt="image-20220607171716-9.png"]] 118 + 119 +**Downlink Command: 0x06** 120 + 121 +Format: Command Code (0x06) followed by 3 bytes. 122 + 123 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 124 + 125 +* ((( 126 +Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 127 +))) 128 +* ((( 129 +Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 130 +))) 131 + 132 +== 3.3 Get Firmware Version Info ~-~--(是否存在) == 133 + 134 +Feature: use downlink to get firmware version. 135 + 136 +**Downlink Command: 0x26** 137 + 138 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171917-10.png?rev=1.1||alt="image-20220607171917-10.png"]] 139 + 140 +* Reply to the confirmation package: 26 01 141 +* Reply to non-confirmed packet: 26 00 142 + 143 +Device will send an uplink after got this downlink command. With below payload: 144 + 145 +Configures info payload: 146 + 147 +|=((( 148 +**Size(bytes)** 149 +)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1** 150 +|**Value**|Software Type|((( 151 +Frequency 152 + 153 +Band 154 +)))|Sub-band|((( 155 +Firmware 156 + 157 +Version 158 +)))|Sensor Type|Reserve|((( 159 +[[Message Type>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H2.3.6MessageType]] 160 +Always 0x02 161 +))) 162 + 163 +**Software Type**: Always 0x03 for LLMS01 164 + 165 +**Frequency Band**: 166 + 167 +*0x01: EU868 168 + 169 +*0x02: US915 170 + 171 +*0x03: IN865 172 + 173 +*0x04: AU915 174 + 175 +*0x05: KZ865 176 + 177 +*0x06: RU864 178 + 179 +*0x07: AS923 180 + 181 +*0x08: AS923-1 182 + 183 +*0x09: AS923-2 184 + 185 +*0xa0: AS923-3 186 + 187 +**Sub-Band**: value 0x00 ~~ 0x08 188 + 189 +**Firmware Version**: 0x0100, Means: v1.0.0 version 190 + 191 +**Sensor Type**: 192 + 193 +0x01: LSE01 194 + 195 +0x02: LDDS75 196 + 197 +0x03: LDDS20 198 + 199 +0x04: LLMS01 200 + 201 +0x05: LSPH01 202 + 203 +0x06: LSNPK01 204 + 205 + 206 + 57 57 = Use AT Command = 58 58 59 59 == Access AT Commands == ... ... @@ -93,16 +93,7 @@ 93 93 94 94 GroPoint Air: 2.45v ~~ 3.6v 95 95 96 -== == 97 97 98 -== Replace Battery == 99 - 100 -Any battery with a range 2.45 ~~ 3.6v can be a replacement. We recommend using Li-SOCl2 Battery. 101 - 102 -And make sure the positive and negative pins match. 103 - 104 -== == 105 - 106 106 == Power Consumption Analyze == 107 107 108 108 Dragino Battery-powered products are all runs in Low Power mode. We have an updated battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit intervals. ... ... @@ -125,7 +125,7 @@ 125 125 Working Mode 126 126 ))) 127 127 128 -And the Life expectation in differen cecase will be shown on the right.269 +And the Life expectation in different cases will be shown on the right. 129 129 130 130 [[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/1654593605679-189.png?rev=1.1||alt="1654593605679-189.png"]] 131 131 ... ... @@ -143,20 +143,21 @@ 143 143 144 144 [[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607172042-11.png?rev=1.1||alt="image-20220607172042-11.png"]] 145 145 146 -=== 4.3.1 Battery Note === 147 147 148 - TheLi-SICO batteryis designed for small current/ long periodapplication. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.288 +=== Battery Note === 149 149 150 - ===4.3.2Replace the battery===290 +The Li-SICO battery is designed for small current / long period applications. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period to transmit LoRa, then the battery life may be decreased. 151 151 152 -You can change the battery in the LLMS01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 153 153 154 - Thedefault battery pack of LLMS01 includes a ER26500 plus super capacitor. If user can’t find this packlocally, theycan find ER26500 orequivalence,which will also work in mostcase. TheSPC can enlarge thebatterylife for high frequency use (update period below 5 minutes)293 +=== Replace the battery === 155 155 295 +You can change the battery in GroPoint Air. The type of battery is not limited as long as the output is between 3v to 3.6v. 156 156 297 +The default battery pack of GroPoint Air includes a ER26500 plus supercapacitor. If users can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most cases. The SPC can enlarge the battery life for high-frequency use (update period below 5 minutes) 157 157 158 158 159 159 301 + 160 160 = FAQ = 161 161 162 162 == How to change the LoRa Frequency Bands/Region ==