From version < 27.1 >
edited by Edwin Chen
on 2022/06/08 23:42
To version < 41.1 >
edited by David Huang
on 2022/06/11 16:36
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.David
Content
... ... @@ -54,6 +54,164 @@
54 54  [[image:image-20220530002453-3.png||height="262" width="493"]]
55 55  
56 56  
57 += Connect LoRaWAN Network =
58 +
59 +
60 +== LED Indicator ==
61 +
62 +The GroPoint Air has an internal LED which can show the status of different states.
63 +
64 +* The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
65 +* Blink once when device transmits a packet.
66 +
67 +== Firmware and Changelog ==
68 +
69 +Firmware Download Location: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/GroPoint_Air/firmware/>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/GroPoint_Air/firmware/]]
70 +
71 +Change Log:
72 +
73 +
74 +
75 += Configure GroPoint Air via AT Command or LoRaWAN Downlink =
76 +
77 +Use can configure GroPoint Air via AT Command or LoRaWAN Downlink.
78 +
79 +* AT Command Connection: See [[FAQ>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H6.FAQ]].
80 +* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>url:http://8.211.40.43/xwiki/bin/view/Main/]]
81 +
82 +There are two kinds of commands to configure GroPoint Air, they are:
83 +
84 +* (((
85 +**~ General Commands**.
86 +)))
87 +
88 +These commands are to configure:
89 +
90 +* General system settings like: uplink interval.
91 +* LoRaWAN protocol & radio-related command.
92 +
93 +They are the same for all Dragino Device that support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>url:http://8.211.40.43/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
94 +
95 +
96 +* (((
97 +**~ Commands special design for GroPoint Air**
98 +)))
99 +
100 +These commands only valid for GroPoint Air, as below:
101 +
102 +== 3.1 Set Transmit Interval Time ==
103 +
104 +Feature: Change LoRaWAN End Node Transmit Interval.
105 +
106 +**AT Command: AT+TDC**
107 +
108 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171554-8.png?rev=1.1||alt="image-20220607171554-8.png"]]
109 +
110 +**Downlink Command: 0x01**
111 +
112 +Format: Command Code (0x01) followed by 3 bytes time value.
113 +
114 +If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
115 +
116 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
117 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
118 +
119 +== 3.2 Set Interrupt Mode ==
120 +
121 +Feature, Set Interrupt mode for GPIO_EXIT.
122 +
123 +**AT Command: AT+INTMOD**
124 +
125 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171716-9.png?rev=1.1||alt="image-20220607171716-9.png"]]
126 +
127 +**Downlink Command: 0x06**
128 +
129 +Format: Command Code (0x06) followed by 3 bytes.
130 +
131 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
132 +
133 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
134 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
135 +
136 +== 3.3 Get Firmware Version Info ==
137 +
138 +Feature: use downlink to get firmware version.
139 +
140 +**Downlink Command: 0x26**
141 +
142 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171917-10.png?rev=1.1||alt="image-20220607171917-10.png"]]
143 +
144 +* Reply to the confirmation package: 26 01
145 +* Reply to non-confirmed packet: 26 00
146 +
147 +Device will send an uplink after got this downlink command. With below payload:
148 +
149 +Configures info payload:
150 +
151 +|=(((
152 +**Size(bytes)**
153 +)))|=**1**|=**1**|=**1**|=**2**|=**1**|=4|=**1**
154 +|**Value**|Software Type|(((
155 +Frequency
156 +
157 +Band
158 +)))|Sub-band|(((
159 +Firmware
160 +
161 +Version
162 +)))|Sensor Type|Reserve|(((
163 +[[Message Type>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H2.3.6MessageType]]
164 +Always 0x02
165 +)))
166 +
167 +**Software Type**: Always 0x03 for LLMS01
168 +
169 +**Frequency Band**:
170 +
171 +*0x01: EU868
172 +
173 +*0x02: US915
174 +
175 +*0x03: IN865
176 +
177 +*0x04: AU915
178 +
179 +*0x05: KZ865
180 +
181 +*0x06: RU864
182 +
183 +*0x07: AS923
184 +
185 +*0x08: AS923-1
186 +
187 +*0x09: AS923-2
188 +
189 +*0x0A: AS923-3
190 +
191 +*0x0B: AS923-4
192 +
193 +**Sub-Band**: value 0x00 ~~ 0x08
194 +
195 +**Firmware Version**: 0x0100, Means: v1.0.0 version
196 +
197 +**Sensor Type**:
198 +
199 +0x01: LSE01
200 +
201 +0x02: LDDS75
202 +
203 +0x03: LDDS20
204 +
205 +0x04: LLMS01
206 +
207 +0x05: LSPH01
208 +
209 +0x06: LSNPK01
210 +
211 +0x07: LDDS45
212 +
213 +0x08: LSLP01
214 +
57 57  = Use AT Command =
58 58  
59 59  == Access AT Commands ==
... ... @@ -78,6 +78,77 @@
78 78  Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLLMS01viaATCommandorLoRaWANDownlink"]].
79 79  
80 80  
239 += Battery & How to replace =
240 +
241 +== Battery Type ==
242 +
243 +GroPoint Air is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is an un-rechargeable battery with a low discharge rate targeting more than 5 years use. This type of battery is commonly used in IoT targets for long-term running, such as water meters.
244 +
245 +The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
246 +
247 +
248 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/1654593587246-335.png?rev=1.1||alt="1654593587246-335.png" height="408" width="574"]]
249 +
250 +Minimum Working Voltage for the GroPoint Air:
251 +
252 +GroPoint Air:  2.45v ~~ 3.6v
253 +
254 +
255 +== Power Consumption Analyze ==
256 +
257 +Dragino Battery-powered products are all runs in Low Power mode. We have an updated battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit intervals.
258 +
259 +Instruction to use as below:
260 +
261 +
262 +**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
263 +
264 +
265 +**Step 2**: Open it and choose
266 +
267 +* (((
268 +Product Model
269 +)))
270 +* (((
271 +Uplink Interval
272 +)))
273 +* (((
274 +Working Mode
275 +)))
276 +
277 +And the Life expectation in different cases will be shown on the right.
278 +
279 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/1654593605679-189.png?rev=1.1||alt="1654593605679-189.png"]]
280 +
281 +The battery-related documents as below:
282 +
283 +* (((
284 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
285 +)))
286 +* (((
287 +[[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
288 +)))
289 +* (((
290 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
291 +)))
292 +
293 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607172042-11.png?rev=1.1||alt="image-20220607172042-11.png"]]
294 +
295 +
296 +=== ​Battery Note ===
297 +
298 +The Li-SICO battery is designed for small current / long period applications. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period to transmit LoRa, then the battery life may be decreased.
299 +
300 +
301 +=== Replace the battery ===
302 +
303 +You can change the battery in GroPoint Air. The type of battery is not limited as long as the output is between 3v to 3.6v.
304 +
305 +The default battery pack of GroPoint Air includes a ER26500 plus supercapacitor. If users can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most cases. The SPC can enlarge the battery life for high-frequency use (update period below 5 minutes)
306 +
307 +
308 +
309 +
81 81  = FAQ =
82 82  
83 83  == How to change the LoRa Frequency Bands/Region ==
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0