... ... @@ -54,6 +54,156 @@
54 54  [[image:image-20220530002453-3.png||height="262" width="493"]]
55 55  
56 56  
57 += Configure GroPoint Air via AT Command or LoRaWAN Downlink =
58 +
59 +Use can configure GroPoint Air via AT Command or LoRaWAN Downlink.
60 +
61 +* AT Command Connection: See [[FAQ>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H6.FAQ]].
62 +* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>url:http://8.211.40.43/xwiki/bin/view/Main/]]
63 +
64 +There are two kinds of commands to configure GroPoint Air, they are:
65 +
66 +* (((
67 +**~ General Commands**.
68 +)))
69 +
70 +These commands are to configure:
71 +
72 +* (((
73 +General system settings like: uplink interval.
74 +)))
75 +* (((
76 +LoRaWAN protocol & radio-related command.
77 +)))
78 +
79 +They are the same for all Dragino Device that support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>url:http://8.211.40.43/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
80 +
81 +
82 +* (((
83 +**~ Commands special design for GroPoint Air**
84 +)))
85 +
86 +These commands only valid for GroPoint Air, as below:
87 +
88 +== 3.1 Set Transmit Interval Time ==
89 +
90 +Feature: Change LoRaWAN End Node Transmit Interval.
91 +
92 +**AT Command: AT+TDC**
93 +
94 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171554-8.png?rev=1.1||alt="image-20220607171554-8.png"]]
95 +
96 +**Downlink Command: 0x01**
97 +
98 +Format: Command Code (0x01) followed by 3 bytes time value.
99 +
100 +If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
101 +
102 +* (((
103 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
104 +)))
105 +* (((
106 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
107 +
108 +
109 +)))
110 +
111 +== 3.2 Set Interrupt Mode  (是否存在) ==
112 +
113 +Feature, Set Interrupt mode for GPIO_EXIT.
114 +
115 +**AT Command: AT+INTMOD**
116 +
117 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171716-9.png?rev=1.1||alt="image-20220607171716-9.png"]]
118 +
119 +**Downlink Command: 0x06**
120 +
121 +Format: Command Code (0x06) followed by 3 bytes.
122 +
123 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
124 +
125 +* (((
126 +Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
127 +)))
128 +* (((
129 +Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
130 +)))
131 +
132 +== 3.3 Get Firmware Version Info ~-~--(是否存在) ==
133 +
134 +Feature: use downlink to get firmware version.
135 +
136 +**Downlink Command: 0x26**
137 +
138 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607171917-10.png?rev=1.1||alt="image-20220607171917-10.png"]]
139 +
140 +* Reply to the confirmation package: 26 01
141 +* Reply to non-confirmed packet: 26 00
142 +
143 +Device will send an uplink after got this downlink command. With below payload:
144 +
145 +Configures info payload:
146 +
147 +|=(((
148 +**Size(bytes)**
149 +)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
150 +|**Value**|Software Type|(((
151 +Frequency
152 +
153 +Band
154 +)))|Sub-band|(((
155 +Firmware
156 +
157 +Version
158 +)))|Sensor Type|Reserve|(((
159 +[[Message Type>>url:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/#H2.3.6MessageType]]
160 +Always 0x02
161 +)))
162 +
163 +**Software Type**: Always 0x03 for LLMS01
164 +
165 +**Frequency Band**:
166 +
167 +*0x01: EU868
168 +
169 +*0x02: US915
170 +
171 +*0x03: IN865
172 +
173 +*0x04: AU915
174 +
175 +*0x05: KZ865
176 +
177 +*0x06: RU864
178 +
179 +*0x07: AS923
180 +
181 +*0x08: AS923-1
182 +
183 +*0x09: AS923-2
184 +
185 +*0xa0: AS923-3
186 +
187 +**Sub-Band**: value 0x00 ~~ 0x08
188 +
189 +**Firmware Version**: 0x0100, Means: v1.0.0 version
190 +
191 +**Sensor Type**:
192 +
193 +0x01: LSE01
194 +
195 +0x02: LDDS75
196 +
197 +0x03: LDDS20
198 +
199 +0x04: LLMS01
200 +
201 +0x05: LSPH01
202 +
203 +0x06: LSNPK01
204 +
205 +
206 +
57 57  = Use AT Command =
58 58  
59 59  == Access AT Commands ==
... ... @@ -78,6 +78,77 @@
78 78  Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLLMS01viaATCommandorLoRaWANDownlink"]].
79 79  
80 80  
231 += Battery & How to replace =
232 +
233 +== Battery Type ==
234 +
235 +GroPoint Air is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is an un-rechargeable battery with a low discharge rate targeting more than 5 years use. This type of battery is commonly used in IoT targets for long-term running, such as water meters.
236 +
237 +The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
238 +
239 +
240 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/1654593587246-335.png?rev=1.1||alt="1654593587246-335.png" height="408" width="574"]]
241 +
242 +Minimum Working Voltage for the GroPoint Air:
243 +
244 +GroPoint Air:  2.45v ~~ 3.6v
245 +
246 +
247 +== Power Consumption Analyze ==
248 +
249 +Dragino Battery-powered products are all runs in Low Power mode. We have an updated battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit intervals.
250 +
251 +Instruction to use as below:
252 +
253 +
254 +**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
255 +
256 +
257 +**Step 2**: Open it and choose
258 +
259 +* (((
260 +Product Model
261 +)))
262 +* (((
263 +Uplink Interval
264 +)))
265 +* (((
266 +Working Mode
267 +)))
268 +
269 +And the Life expectation in different cases will be shown on the right.
270 +
271 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/1654593605679-189.png?rev=1.1||alt="1654593605679-189.png"]]
272 +
273 +The battery-related documents as below:
274 +
275 +* (((
276 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
277 +)))
278 +* (((
279 +[[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
280 +)))
281 +* (((
282 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
283 +)))
284 +
285 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LLMS01-LoRaWAN%20Leaf%20Moisture%20Sensor%20User%20Manual/WebHome/image-20220607172042-11.png?rev=1.1||alt="image-20220607172042-11.png"]]
286 +
287 +
288 +=== ​Battery Note ===
289 +
290 +The Li-SICO battery is designed for small current / long period applications. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period to transmit LoRa, then the battery life may be decreased.
291 +
292 +
293 +=== Replace the battery ===
294 +
295 +You can change the battery in GroPoint Air. The type of battery is not limited as long as the output is between 3v to 3.6v.
296 +
297 +The default battery pack of GroPoint Air includes a ER26500 plus supercapacitor. If users can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most cases. The SPC can enlarge the battery life for high-frequency use (update period below 5 minutes)
298 +