<
From version < 32.9 >
edited by Xiaoling
on 2022/06/24 14:57
To version < 32.7 >
edited by Xiaoling
on 2022/06/24 14:56
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -80,6 +80,7 @@
80 80  
81 81  
82 82  
83 +
83 83  == 2.2 How it works? ==
84 84  
85 85  (((
... ... @@ -100,6 +100,7 @@
100 100  
101 101  
102 102  
104 +
103 103  == 2.3 Example to use for LoRaWAN network ==
104 104  
105 105  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -158,6 +158,7 @@
158 158  
159 159  
160 160  
163 +
161 161  === 2.4.1 Uplink FPORT~=5, Device Status ===
162 162  
163 163  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -401,6 +401,7 @@
401 401  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
402 402  
403 403  
407 +
404 404  == 3.2 Set Emergency Mode ==
405 405  
406 406  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -416,6 +416,7 @@
416 416  * 0xE100     Same as: AT+ALARMMOD=0
417 417  
418 418  
423 +
419 419  == 3.3 Add or Delete RS485 Sensor ==
420 420  
421 421  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -432,6 +432,7 @@
432 432  * has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
433 433  * timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
434 434  
440 +
435 435  **Example:**
436 436  
437 437  User need to change external sensor use the type code as address code.
... ... @@ -456,6 +456,7 @@
456 456  * has_CRC: 1
457 457  * timeout: 1500 (Fill in the test according to the actual situation)
458 458  
465 +
459 459  **So the input command is:**
460 460  
461 461  AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500
... ... @@ -485,6 +485,7 @@
485 485  * 0xE5FF  
486 486  
487 487  
495 +
488 488  == 3.4 RS485 Test Command ==
489 489  
490 490  (% style="color:#037691" %)**AT Command:**
... ... @@ -507,6 +507,7 @@
507 507  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
508 508  
509 509  
518 +
510 510  == 3.5 RS485 response timeout ==
511 511  
512 512  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -521,6 +521,7 @@
521 521  Range : 0~~10000
522 522  )))|(% style="width:85px" %)OK
523 523  
533 +
524 524  (% style="color:#037691" %)**Downlink Command:**
525 525  
526 526  Format: Command Code (0xE0) followed by 3 bytes time value.
... ... @@ -531,6 +531,7 @@
531 531  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
532 532  
533 533  
544 +
534 534  == 3.6 Set Sensor Type ==
535 535  
536 536  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
... ... @@ -547,6 +547,7 @@
547 547  |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response**
548 548  |(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK
549 549  
561 +
550 550  Eg: The setting command **AT+STYPE=802212** means:
551 551  
552 552  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %)
... ... @@ -583,15 +583,13 @@
583 583  The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server.
584 584  
585 585  
598 +
586 586  == 4.3 Battery ==
587 587  
588 -(((
589 -All sensors are only power by external power source. If external power source is off. All sensor won't work.
590 -)))
601 +All sensors are only power by external power source. If external power source is off. All sensor won’t work.
591 591  
592 -(((
603 +
593 593  Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid.  External power source can recharge the 1000mAh rechargeable battery.
594 -)))
595 595  
596 596  
597 597  
... ... @@ -611,10 +611,6 @@
611 611  * IP Rating: IP65
612 612  * Support default sensors or 3rd party RS485 sensors
613 613  
614 -
615 -
616 -
617 -
618 618  == 5.2 Power Consumption ==
619 619  
620 620  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0