Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/05/07 14:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -78,6 +78,9 @@ 78 78 * Cabinet. 79 79 80 80 81 + 82 + 83 + 81 81 == 2.2 How it works? == 82 82 83 83 ((( ... ... @@ -96,6 +96,9 @@ 96 96 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 97 97 98 98 102 + 103 + 104 + 99 99 == 2.3 Example to use for LoRaWAN network == 100 100 101 101 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -152,6 +152,9 @@ 152 152 * Valid Sensor Value: Use FPORT=2 153 153 * Other control command: Use FPORT other than 2. 154 154 161 + 162 + 163 + 155 155 === 2.4.1 Uplink FPORT~=5, Device Status === 156 156 157 157 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -396,7 +396,6 @@ 396 396 397 397 398 398 399 - 400 400 == 3.2 Set Emergency Mode == 401 401 402 402 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -413,7 +413,6 @@ 413 413 414 414 415 415 416 - 417 417 == 3.3 Add or Delete RS485 Sensor == 418 418 419 419 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -420,7 +420,7 @@ 420 420 421 421 (% style="color:#037691" %)**AT Command: ** 422 422 423 -AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout 430 +(% style="color:blue" %)**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout** 424 424 425 425 * Type_Code range: A1 ~~ A4 426 426 * Query_Length: RS485 Query frame length, Value cannot be greater than 10 ... ... @@ -430,24 +430,23 @@ 430 430 * has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 431 431 * timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 432 432 433 -Example: 434 434 441 +**Example:** 442 + 435 435 User need to change external sensor use the type code as address code. 436 436 437 437 With a 485 sensor, after correctly changing the address code to A1, the RS485 query frame is shown in the following table: 438 438 439 -|Address Code|Function Code|(% colspan="2" %)Start Register|(% colspan="2" %)Data Length|CRC Check Low|CRC Check High 440 -|0xA1|0x03|0x00|0x00|0x00|0x01|0x9C|0xAA 441 -| | | | | | | | 447 +[[image:image-20220624143553-10.png]] 442 442 449 + 443 443 The response frame of the sensor is as follows: 444 444 445 -|Address Code|Function Code|(% colspan="2" %)Data Length|(% colspan="2" %)Data|CRC Check Low|CRC Check High 446 -|0xA1|0x03|0x00|0x02|0x00|0x0A|0x7C|0xAD 447 -| | | | | | | | 452 +[[image:image-20220624143618-11.png]] 448 448 449 -Then the following parameters should be: 450 450 455 +**Then the following parameters should be:** 456 + 451 451 * Address_Code range: A1 452 452 * Query_Length: 8 453 453 * Query_Command: A103000000019CAA ... ... @@ -456,21 +456,23 @@ 456 456 * has_CRC: 1 457 457 * timeout: 1500 (Fill in the test according to the actual situation) 458 458 459 -So the input command is: 460 460 466 +**So the input command is:** 467 + 461 461 AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500 462 462 463 463 464 464 In every sampling. WSC1-L will auto append the sensor segment as per this structure and uplink. 465 465 466 -|Type Code|Length (Bytes)|Measured Value 467 -|A1|2|0x000A 473 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:351px" %) 474 +|=(% style="width: 94px;" %)Type Code|=(% style="width: 121px;" %)Length (Bytes)|=(% style="width: 132px;" %)Measured Value 475 +|(% style="width:94px" %)A1|(% style="width:121px" %)2|(% style="width:132px" %)0x000A 468 468 469 -Related commands: 477 +**Related commands:** 470 470 471 -AT+DYSENSOR=A1,0 –> Delete 3^^rd^^ party sensor A1.479 +AT+DYSENSOR=A1,0 ~-~-> Delete 3^^rd^^ party sensor A1. 472 472 473 -AT+DYSENSOR ~-~-> List All 3^^rd^^ Party Sensor. Like below: 481 +AT+DYSENSOR ~-~-> List All 3^^rd^^ Party Sensor. Like below: 474 474 475 475 476 476 (% style="color:#037691" %)**Downlink Command: ** ... ... @@ -485,17 +485,17 @@ 485 485 486 486 487 487 488 - 489 489 == 3.4 RS485 Test Command == 490 490 491 491 (% style="color:#037691" %)**AT Command:** 492 492 493 -|**Command Example**|**Function**|**Response** 494 -|AT+RSWRITE=xxxxxx|((( 500 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:474px" %) 501 +|=(% style="width: 159px;" %)**Command Example**|=(% style="width: 227px;" %)**Function**|=(% style="width: 85px;" %)**Response** 502 +|(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)((( 495 495 Send command to 485 sensor 496 496 497 497 Range : no more than 10 bytes 498 -)))|OK 506 +)))|(% style="width:85px" %)OK 499 499 500 500 Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor 501 501 ... ... @@ -508,7 +508,6 @@ 508 508 509 509 510 510 511 - 512 512 == 3.5 RS485 response timeout == 513 513 514 514 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -515,13 +515,15 @@ 515 515 516 516 (% style="color:#037691" %)**AT Command:** 517 517 518 -|**Command Example**|**Function**|**Response** 519 -|AT+DTR=1000|((( 525 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:433px" %) 526 +|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 188px;" %)**Function**|=(% style="width: 85px;" %)**Response** 527 +|(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)((( 520 520 Set response timeout to: 521 521 522 522 Range : 0~~10000 523 -)))|OK 531 +)))|(% style="width:85px" %)OK 524 524 533 + 525 525 (% style="color:#037691" %)**Downlink Command:** 526 526 527 527 Format: Command Code (0xE0) followed by 3 bytes time value. ... ... @@ -533,50 +533,32 @@ 533 533 534 534 535 535 536 - 537 537 == 3.6 Set Sensor Type == 538 538 539 539 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. 540 540 541 -See [[definition>>||anchor="H"]] for the sensor type. 549 +See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type. 542 542 551 +[[image:image-20220624144904-12.png]] 543 543 544 -|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16 545 -| |A4|A3|A2|A1| | | 546 -|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8 547 -| | |Solar Radiation|PAR|PM10|PM2.5|((( 548 -Rain 549 549 550 -Gauge 551 -)))|((( 552 -Air 553 553 554 -Pressure 555 -))) 556 -|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0 557 -|Humidity|Temperature|CO2|((( 558 -Rain/Snow 559 - 560 -Detect 561 -)))|illuminance|((( 562 -Wind 563 - 564 -Direction 565 -)))|Wind Speed|BAT 566 - 567 567 (% style="color:#037691" %)**AT Command:** 568 568 569 -|**Command Example**|**Function**|**Response** 570 -|AT+STYPE=80221|Set sensor types|OK 557 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %) 558 +|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response** 559 +|(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK 571 571 561 + 572 572 Eg: The setting command **AT+STYPE=802212** means: 573 573 574 -|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16 575 -|0|0|0|0|1|0|0|0 576 -|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8 577 -|0|0|0|0|0|0|1|0 578 -|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0 579 -|0|0|1|0|0|0|0|1 564 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %) 565 +|(% rowspan="2" style="width:57px" %)Byte3|(% style="width:57px" %)Bit23|(% style="width:59px" %)Bit22|(% style="width:56px" %)Bit21|(% style="width:51px" %)Bit20|(% style="width:54px" %)Bit19|(% style="width:54px" %)Bit18|(% style="width:52px" %)Bit17|(% style="width:52px" %)Bit16 566 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)1|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)0 567 +|(% rowspan="2" style="width:57px" %)Byte2|(% style="width:57px" %)Bit15|(% style="width:59px" %)Bit14|(% style="width:56px" %)Bit13|(% style="width:51px" %)Bit12|(% style="width:54px" %)Bit11|(% style="width:54px" %)Bit10|(% style="width:52px" %)Bit9|(% style="width:52px" %)Bit8 568 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)1|(% style="width:52px" %)0 569 +|(% rowspan="2" style="width:57px" %)Byte1|(% style="width:57px" %)Bit7|(% style="width:59px" %)Bit6|(% style="width:56px" %)Bit5|(% style="width:51px" %)Bit4|(% style="width:54px" %)Bit3|(% style="width:54px" %)Bit2|(% style="width:52px" %)Bit1|(% style="width:52px" %)Bit0 570 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)1|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)1 580 580 581 581 So wsc1-L will upload the following data: Custom Sensor A1, Rain Gauge,CO2,BAT. 582 582 ... ... @@ -587,12 +587,11 @@ 587 587 588 588 (% style="color:red" %)**Note:** 589 589 590 -~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned 581 +~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned. 591 591 592 592 593 593 594 594 595 - 596 596 = 4. Power consumption and battery = 597 597 598 598 == 4.1 Total Power Consumption ==
- image-20220624143553-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +6.7 KB - Content
- image-20220624143618-11.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +6.3 KB - Content
- image-20220624144904-12.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.2 KB - Content